Owners &
Installation Manual
C33ClassicFreestandingGasStove
ClassicC33modelshownabovefeatures
optional gold plated door and gold legs.
MODELS: C33-NG2 Natural Gas C33-LP2 Propane
WARNING:
FOR YOUR SAFETY
Iftheinformationintheseinstructionsarenotfollowedexactly, What to do if you smell gas:
a fire or explosion may result causing property damage,
personal injury or loss of life.
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
908-636a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
01/31/05
TABLE OF CONTENTS
Page
Page
Safety Label
OperatingInstructions
SafetyLabel ............................................................. 4-5
OperatingInstructions ............................................... 14
LightingProcedure .................................................... 14
ShutdownProcedure ................................................. 14
Copy of Lighting Plate Instructions ............................ 15
Installation
Before you start .......................................................... 6
GeneralSafetyInformation .......................................... 6
Installation Checklist ................................................... 7
ClearancestoCombustibles ....................................... 7
OptionalFanInstallation.............................................. 7
Pedestal Assembly ..................................................... 8
Leg and Bottom Shield Assembly ............................... 9
Optional Outside Air .................................................... 9
-Outside air through pedestal bottom .................... 9
-Outsideairthroughpedestalrear ......................... 9
DraftHood ................................................................... 9
Venting ....................................................................... 9
-Ventingrequirements........................................... 9
GasConnection ........................................................ 10
System Data Table ................................................... 10
HighElevation ........................................................... 10
Gas Pipe Pressure Testing ....................................... 10
Test for Flue Spillage ................................................ 11
Log Set Installation ................................................... 11
Safety Latch.............................................................. 12
DoorHandle .............................................................. 12
Optional Remote Wall Switch.................................... 12
OptionalRemoteControlInstallation ......................... 12
OptionalWallThermostat .......................................... 12
WiringDiagram ......................................................... 13
Final Check............................................................... 12
Normal Operating Sounds of Gas Appliances ............ 13
Maintenance
MaintenanceInstructions .......................................... 14
GeneralVentMaintenance ........................................ 16
Thermopile/Thermocouple ......................................... 16
AerationAdjustment.................................................. 16
Pilot Adjustment ....................................................... 16
LogReplacement ...................................................... 17
Gold Plated Doors ..................................................... 17
GlassReplacement................................................... 17
RemovingValveAssembly ........................................ 18
InstallingValveAssembly ......................................... 18
Partslist
Replacement & Spare Parts List ............................... 19
Warranty
Warranty ................................................................... 23
Regency CLASSIC C33-2 Freestanding Gas Stove
3
SAFETY LABEL
This is a copy of the label that accompanies
each CLASSIC Freestanding Gas Stove - Nat-
ural Gas. We have printed a copy of the
contents here for your review. The safety label
is located on the back panel.
NOTE: Regency units are constantly being
improved.Checkthelabelontheunitandifthere
is a difference, the label on the unit is the correct
one.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Serial No.
201
Listed: GAS FIRED VENTED ROOM HEATER
Certified for: CANADA and USA
Report No. 476-1345-00 (Oct. 1996)
Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003,
CAN/CGA-2.17-M91
FACTORY EQUIPPED FOR NATURAL GAS:
Model C33-NG2
Factory Equipped for 0-2000 ft.
Minimum supply pressure 5"
WC/C.E. (1.25Kpa)
WC/C.E. (0.94Kpa)
WC/C.E. (0.27Kpa)
DMS
Manifold pressure High
Manifold pressure Low
Orifice size
3.8"
1.1"
36
Altitude
Maximum Input
Minimum Input
0-2000 ft/pi
33,000 BTUH (9.67Kw/h)
17,000 BTUH (4.98Kw/h)
(0-610 m)
HIGH ALTITUDE CONVERTED NATURAL GAS:
Model C33-NG2
Field Convertable for Altitude 2000-4500 ft.
(Report No.476-1345-00)
Minimum supply pressure 5"
WC/C.E. (1.25Kpa)
WC/C.E. (0.94Kpa)
WC/C.E. (0.27Kpa)
DMS
Manifold pressure High
Manifold pressure Low
Orifice size
3.8"
1.1"
38
Altitude
Maximum Input
Minimum Input
2000-4500 ft/pi (610-1370m)
29,000 BTUH (8.5Kw/h)
15,300 BTUH (4.48Kw/h)
GAS FIRED VENTED ROOM HEATER
This appliance must be installed in accordance
with local codes, if any; If not, follow:
ANSI Z223.1/CAN 1-B149.
Electrical Supply (115 V, 1.13 A, 60 Hz)
Not for use with solid fuel.
Optional Fan: (Part #490-917)
Minimum Clearances to Combustibles
Back wall
Back wall
B
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
A
A
E
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
A - 10"
B - 6"
E - 1.5"
Minimum ceiling height from top of unit: 36"/914mm
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
DO NOT REMOVE THIS LABEL
Made in Canada
908-634a
4
Regency CLASSIC C33-2 Freestanding Gas Stove
SAFETY LABEL
Thisisacopyofthelabelthataccompanieseach
CLASSIC Freestanding Gas Stove - Propane.
We have printed a copy of the contents here for
your review. The safety label is located on the
back panel.
NOTE: Regency units are constantly being im-
proved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Serial No.
200
Listed: GAS FIRED VENTED ROOM HEATER
Certified for: CANADA and USA
Report No. 476-1345-00 (Oct. 1996)
Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003
FACTORY EQUIPPED FOR PROPANE:
Model C33-LP2
Minimum supply pressure 12"
WC/C.E.(2.85Kpa)
WC/C.E.(2.61Kpa)
WC/C.E.(0.72Kpa)
DMS
Manifold pressure High
Manifold pressure Low
Orifice size
11"
2.9"
52
Altitude
0-2000 ft/pi
(0-610 m)
Maximum Input
Minimum Input
33,000 BTUH (9.67Kw/h)
17,000 BTUH (4.98Kw/h)
GAS FIRED VENTED ROOM HEATER
This appliance must be installed in accordance
with local codes, if any; If not, follow:
ANSI Z223.1/CAN 1-B149.
Electrical Supply (115 V, 1.13 A, 60 Hz)
Not for use with solid fuel.
Optional Fan: (Part #490-917)
Minimum Clearances to Combustibles
Back wall
Back wall
B
A
A
E
A - 10"
B - 6"
E - 1.5"
Minimum ceiling height from top of unit: 36"/914mm
DO NOT REMOVE THIS LABEL
Made in Canada
908-635a
Regency CLASSIC C33-2 Freestanding Gas Stove
5
INSTALLATION
12) Under no circumstances should this appli-
ance be modified. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
IMPORTANT:
SAVE THESE
INSTRUCTIONS
BEFORE YOU START
Safeinstallationandoperationofthisappliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:
13) Installation and any repairs to this appli-
ance should be done by a qualified service
person. A professional service person
should be called to inspect this appliance
annually. Make it a practice to have all of
your gas appliances checked annually.
TheCLASSICFreestandingGasStovemustbe
installed in accordance with these instructions.
Carefully read all the instructions in this manual
first. Consult the "authority having jurisdiction"
to determine the need for a permit prior to
starting the installation.
INSTALLATION AND REPAIR
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THE AP-
PLIANCESHOULDBEINSPECTED
BEFORE USE AND AT LEAST AN-
NUALLY BY A PROFESSIONAL
SERVICE PERSON. MORE FRE-
QUENT CLEANING MAY BE RE-
QUIREDDUETOEXCESSIVELINT
FROMCARPETING,BEDDINGMA-
TERIAL, ETC. IT IS IMPERATIVE
THAT CONTROL COMPART-
MENTS,BURNERSANDCIRCULAT-
ING AIR PASSAGEWAYS OF THE
APPLIANCEBEKEPTCLEAN.
14) Do not strike the glass door.
15) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
GENERAL SAFETY
INFORMATION
16) The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
1) The appliance installation must conform
with local codes or, in the absence of local
codes, with the current Canadian or Nation-
al Gas Codes, CAN1-B149 or ANSI Z223.1
Installation Codes.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
2) Theappliancewheninstalled, mustbeelec-
trically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA70orCSAC22.1CanadianElectrical
Code.
INSTALLATION
CHECKLIST
DUE TO HIGH TEMPERATURES,
THEAPPLIANCESHOULDBELO-
CATED OUT OF TRAFFIC AND
AWAYFROMFURNITUREANDDRA-
PERIES.
3) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
1) Locate appliance, see Clearances to Com-
bustibles, page 7.
2) Install Optional Fan, page 7.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
MAY CAUSE A SERIOUS HOUSE
FIREANDWILLVOIDYOURWAR-
RANTY.
3) Assemble stove base - pedestal or legs,
4) This appliance is Listed for Alcove installa-
tions, maintainminimumAlcoveclearances
as follows, minimum ceiling height of 65-11/
16", minimum width of 48" and a maximum
depth of 36".
pages 8 and 9.
4) If outside air is being used, see page 9.
5) Install venting, page 9.
5) This unit is not approved for installation into
CHILDRENANDADULTSSHOULD
BEALERTEDTOTHEHAZARDSOF
HIGHSURFACETEMPERATURES,
ESPECIALLY THE FIREPLACE
GLASS,ANDSHOULDSTAYAWAY
TO AVOID BURNS OR CLOTHING
IGNITION.
6) Make gas and electrical connections, page
10. Test the pilot. Must be as per diagram,
pages 16.
a mobile home.
6) See general construction and assembly
instructions.
7) Test gas pressure, page 10.
8) Test for flue spillage, page 11.
9) Install log set, see page 11.
7) This appliance must be connected to a vent
and terminate to the outside of the building
envelope. Never vent to another room or
inside a building.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISEDWHEN
THEYAREINTHESAMEROOMAS
THEAPPLIANCE.
10) Install optional Wall Switch, Remote Con-
8) Inspect the venting system annually for
trol, or Wall Thermostat, page 12.
blockage and any signs of deterioration.
11) Final check, page 12.
9) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to cus-
tomer.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACEDONORNEARTHEAPPLI-
ANCE.
10) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) after
burning appliance for 15 minutes.
11) Wear gloves and safety glasses for pro-
tection while doing required maintenance.
6
Regency CLASSIC C33-2 Freestanding Gas Stove
INSTALLATION
4) Screw the four 8-32 x 3/4 screws provided
into the nutserts as shown in diagram 3. Do
not tighten screws.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15-20 min. to
stabilize.
OPTIONAL FAN
INSTALLATION
5) Push all the fan wires through the hole on
the fan assembly. See diagram 2
.
6) Put power cord (shown in diagram 3)
through the hole and pull through to front of
unit for easier installation of ground wire.
3) Check for proper draft.
Important: Disconnect the power
supplybeforeinstallationorservic-
ing.
CAUTION:Anyalterationtotheprod-
uct that causes sooting or carbon-
ingthatresultsindamageisnotthe
responsibility of the manufacturer.
For pedestal unit: To install the fan in an
installed stove-access from front through
the pedestal by following the directions
below. If the stove is not installed - access
through rear and follow steps 4 to 17.
7) Place fan assembly partially in door cover
plate hole. See diagram 2.
CLEARANCES TO
COMBUSTIBLES
8) Attach the 2 ground wires (green) to the
ground lug as per diagram 2.
Note:
Ground lug is located on the bottom
The clearances listed below are MINIMUM dis-
tances. Measure the clearance to both the
appliance and the chimney connector. The
farthest distance is correct if the two clearanc-
esdonotcoincide.Forexample,iftheappliance
issetasindicatedinoneofthediagramsbutthe
back wall is too close, move the stove until the
correct clearance to the back wall is obtained.
of the fan assembly. See diagram 2.
For leg unit: remove 7 screws, remove
bottom access panel and install fan as-
sembly and follow steps 4 to 17.
Thisunitcanbeinstalledonasolidcombustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with the
unit) is installed.
1) Open pedestal door and remove door cov-
er plate by removing 4 screws. See dia-
gram 1.
This appliance may be installed only with the
clearances as shown in the situations pic-
tured. Do not combine clearances from one
type of installation with another in order to
achieve closer clearances. Use the minimum
clearances shown in the diagrams. Alcove
installations are approved, as long as side wall
clearances are maintained.
Diagram 3
9) Lift the fan assembly in through the pedes-
tal and up through the cut out as shown in
diagrams 3 and 4.
C33-2 Clearances to Combustibles
10) Put the insulation gasket on the back of the
fan. Line up the keyhole slots with the
matching screws and pull back slightly to
lock into place. While holding fan assembly
in place, tighten screws.
A
B
E
Side Wall to Unit
Back Wall to Unit
Side Wall to Unit
10" / 250 mm
6" / 150 mm
1.5" / 38 mm
Diagram 1
C33-2 Reference Dimensions
to Flue Centerline
2) Remove valve cover plate by removing 2
C
D
F
Back Wall
11-1/2"/ 292 mm
22" / 559 mm
13" / 330 mm
screws.
Side Wall
Side Wall
3) Remove wire from piezo ignitor.
Minimum ceiling height is 36" / 914 mm
from top of unit.
Diagram 4
Diagram 2
Regency CLASSIC C33-2 Freestanding Gas Stove
7
INSTALLATION
16) Pull power wire back and put strain relief
Wiring
PEDESTAL ASSEMBLY
grommet in place as per diagram 4.
11) Remove the dummy plug from the right side
of the bottom shield or pedestal and install
the supplied fan switch.
1) For easier assembly, tip the stove on its
back (preferably onto a soft surface to
prevent scratching).
17) Reverse steps 3-1 to complete installation.
Note: The #8 ground lug is a dedicated
ground for mobile home use only.
12) Attach hot wire from power cord to the
2) Unscrew the 4 bolts in the underside of the
stove. Align the holes in the corners of the
pedestal top with the corresponding holes
in the base of the stove. Use washers
which are supplied with the pedestal as
shown in diagram. Reinstall bolts.
OnlyC34unitisapprovedformobilehomes.
thermodisc.
Caution: Ensure that wires do
NOTtouchhotsurfaces.
13) Slide the thermodisc under the bracket.
Fan Removal
1) Disconnect the power to fan.
2) Allow the stove to cool to room tempera-
ture.
3) Open the pedestal door and remove the
screws on the door cover plate. Leg Units:
Remove bottom access panel.
4) Loosen the nutsert screws.
5) Remove Fan Assembly from the key slots
at the fan base. Take the fan out from the
rectangular opening . Diagram 3.
6) Turn the fan around 90 degrees (Pedestal
units only). Diagram 2.
View from Bottom of Stove
7) Disconnect the green ground wires to the
grounding lug.
14) Connecting wires to the 3 way switch -
a. Connect the red wire from the fan to the
top of the 3 way switch.
8) Disconnect the white wire of the fan from
the power cord.
b. Connect black wire from fan to the bottom
of the 3 way switch.
Diagram 1
9) Disconnect red wire and black wire (from
c. Connect white jumper wire to middle of
the three way switch. See wiring diagram
below.
fan to Fan Switch).
3) Hook up wires to Burner ON/OFF switch
and valve assembly (be careful not to pinch
wires). See Diagram 1.
10) Take fan out from the stove body. Diagram
1.
15) Connect white wire from fan motor to neu-
4) Push the Regency logo into the two holes
in the front bottom left corner of the pedestal
cover plate.
tral on the power cord.
Note: Any paint touch up should be done
prior to placing logo on pedestal.
Wiring Diagram
8
Regency CLASSIC C33-2 Freestanding Gas Stove
INSTALLATION
IMPORTANT
OPTIONAL
OUTSIDE AIR
LEG AND
BOTTOM SHIELD
ASSEMBLY
Read all instructions carefully before starting
the installation. Failure to follow these instruc-
tions may create a fire or other safety hazard,
and will void the warranty. Be sure to check the
venting and clearance to combustible require-
If needed, outside air for combustion can be
brought in either through the bottom of the
pedestal or through the rear plate of the pedes-
tal.
These instructions apply to the steel leg, paint-
ed cast leg and the gold plated cast leg. It will
be easier to attach the legs to the stove if it is
tipped on its back (preferably on a soft surface
to prevent scratching).
ments.
Consult your local building codes
before beginning installation.
Thepedestalcoverplatemustbeinstalledwhen
using outside combustion air. Loosen the 4
screws on the rear of the pedestal and slide the
cover plate over them. Slide the plate to the left
to center it and tighten down the 4 screws.
DRAFT HOOD
1) Remove the 4 bolts in the underside of the
base and discard.
The heater has a draft hood built into its back.
It must not be altered or obstructed, and the unit
must be installed so that the draft hood is in the
same atmospheric pressure zone as the com-
bustion air inlet to the burner.
2) Put the bottom shield up against the bottom
of the stove and loosely install the four
supplied bolts and washers into the thread-
ed holes in the four corners of the bottom
the unit. Once the bolts are started, slip the
leg under the washer and tighten the bolts.
Outside Air Through
Pedestal Bottom
Once you have properly marked the position of
your unit as outlined in "General Information"
and "Clearances to Combustibles", cut a mini-
mum 3 inch diameter hole though the floor
directly under your pedestal base to the outside.
Pipe fresh air into the pedestal area by using a
minimum 3" duct pipe with a mesh grill at the
outside termination.
VENTING
3) Hook up wires to Burner ON/OFF switch
and valve assembly as per pedestal as-
sembly diagram (diagram 1).
This heater is a vented appliance and must be
connected to a chimney/flue in accordance
with installation codes.
4) Level the stove by adjusting the levelling
Note: The rear cover plate is only at-
tached when outside air is being
used. Do not install it when using
room air for combustion.
bolts in the bottom of each leg.
Note: Blanking plate combustion air hole
is 4" diameter.
For your safety this heater is equipped with a
vent safety switch. This thermally actuated
switch is located within the draft hood and will
detect either a blocked chimney or backdraft
condition where the chimney flow has re-
versed and will react by shutting off the gas
supply.
Note: The spill switch is manually reset-
table and comes from the factory
in the open position. Before trying
to start up the unit, make sure the
red button on the spill switch is
pushed in.
Rear View
Outside Air Through
Pedestal Rear
Remove the blanking plate from the rear of the
pedestal cover plate and bend the two tabs out
90degrees.Pipefreshairintothepedestalarea
byusingaminimum3"ductpipewithameshgrill
at the outside termination. Attach the pipe to the
tabs with screws.
Venting Requirements
Four inch diameter vent is required. B-Vent,
Class A or Masonry with a liner are all accept-
able. Follow all venting manufacturer’s require-
ments and local building codes. For altitudes
above 2000 ft. we recommend that a minimum
flue height of 12 ft. is used.
Note: The hole in the rear pedestal cov-
er plate is 4" diameter.
Note: Proper sizing of gas vents is crit-
ical to proper operation of all gas
stoves and fireplaces. Ensure that
proper sizing tables or vent man-
ufacturers instructions are fol-
lowed.
Side View
Regency CLASSIC C33-2 Freestanding Gas Stove
9
INSTALLATION
Installing into Existing
Woodstove Flue System
GAS PIPE
PRESSURE TESTING
SYSTEM DATA
(For 0 to 2,000 feet altitude)
1) Clean existing chimney system.
Orifice Sizes:
Burner
Burner
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnect piping from valve at pres-
sures over 1/2 psig (14" w.c.).
Natural Gas
Propane
#36
#52
2) Install stove pipe adapter
3) Install any reducers that may be needed to
Max. Input Rating
Natural Gas
Propane
fit 6" flue pipe adapter.
33,000 Btu/h
33,000 Btu/h
4) Run 4" flex liner into existing chimney.
Min. Input Rating
Natural Gas
Propane
5) Slip liner through 6" flue pipe and hook up
The manifold pressure is controlled by a reg-
ulator built into the gas control, and should be
checked at the pressure test point.
17,000 Btu/h
17,000 Btu/h
to flue collar with screws.
Note: For ease of instal-
lation, use a slip
section when in-
s t a l l i n g
Output Capacity with blower Off
Note: To properly check gas pressure,
both inlet and manifold pressures
should be checked using the valve
pressure ports on the valve.
Natural Gas
Propane
23,200 Btu/h
23,100 Btu/h
with a ver-
tical flue
Output Capacity with blower On
Natural Gas
Propane
24,600 Btu/h
24,420 Btu/h
pipe.
1) Makesurethevalveisinthe"OFF"position.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a
1/8" wide flat screwdriver.
Supply Pressure
Natural Gas
min.
max.
min.
5.0" w.c
8.0" w.c.
12.0" w.c.
13.0" w.c.
Propane
3) Attach manometer to "IN" and/or "OUT"
max.
pressure tap(s) using a 5/16" ID hose.
Manifold Pressure High
4) Light the pilot and turn the valve to "ON"
Natural Gas
Propane
3.8" +/- 0.2" w.c.
11" +/- 0.2" w.c.
position.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specified on the safety
label.
Manifold Pressure Low
Natural Gas
Propane
1.1" +/- 0.2" w.c.
2.9" +/- 0.2" w.c.
Electrical: 120V, 1.13A, 60 Hz.
Circulation Fan: (optional) 2 speed
75/125 CFM.
6) When finished reading manometer, turn off
the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
flat screwdriver. Screw should be snug,
but do not over tighten.
GAS CONNECTION
Log Set: Ceramic fiber, 4 per set.
Thegasconnectionisa3/8"NPTrigidpipe.The
gas line can be rigid pipe or to make installation
easier, use a listed flexible connector and/or
copper pipe if allowed by local codes. For
minimum and maximum supply pressure see
the System Data table below.
HIGH ELEVATION
This unit is approved in Canada for altitude 0 to
4500 ft. (CAN1 2.17-M90) with the orifice sup-
plied.
Note: During any pressure testing of
the gas supply piping system that
exceeds test pressures of 1/2
psig, this appliance and its indi-
vidual shut-off valve must be dis-
connected from the piping sys-
tem. If test pressures equal to or
less than 1/2 psig are used then
this appliance must be isolated
from the piping system by clos-
ing its individual manual shut-off
valve during the testing.
SYSTEM DATA
(For 2,000 to 4,500 feet altitude)
Orifice Sizes:
Burner
Natural Gas
#38
Max. Input Rating
Natural Gas
29,000 Btu/h
Min. Input Rating
Natural Gas
15,300 Btu/h
Output capacity:
Output Capacity with blower Off
Natural Gas 20,400 Btu/h
The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and
was determined independently of any installed
system.
Output Capacity with blower On
Natural Gas 21,600 Btu/h
10
Regency CLASSIC C33-2 Freestanding Gas Stove
INSTALLATION
1) Start all exhaust fans in the home and then The gas log kit contains the following:
close all doors and windows in the room.
Valve Description
a) Front Log
b) Rear Log
c) Small Cross Logs (2)
d) Bag of embers
e) Bag of rock wool
1) Gas cock knob
2) Manual high/low adjustment
3) Pilot Adjustment
4) Thermocouple Connection
5) Main Operator
6) Outlet Pressure Tap
7) Inlet Pressure Tap
8) PilotOutlet
9) Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
2) Light the unit and set controls to maximum.
3) After five minutes, test that there is a “pull”
on the flue by placing a smoke match,
cigarette or similar device which gives off
smoke, on the edge of the draft hood. See 1) Remove the logs from the box and carefully
Diagram below.
unwrap them. The logs are fragile,
handle with care. Do not force into
position.
The smoke should be drawn into the draft hood.
If the smoke is still not drawn into the draft hood,
turn the unit off and check for the cause of the 2) Place the rear deflector on the rear log
lack of draft. If necessary, seek expert advice. support pins in the back of the unit.
13) Additional Valve Mounting Hole
Note: If the flue is blocked or has a strong 3) Placetherearlogintotherearofthefirebox,
reverse flow, the thermally actuat-
ed safety switch mounted in the
draft hood will automatically shut
off the gas supply in less than 10
minutes. If the heater turns off
aligningtheholesontheundersideofthelog
with the rear log support pins and carefully
push the log down onto the pins. See
diagrams 1 and 2.
because of this during the spillage 4) Ensure the front deflector is over front log
test, check for the cause of the lack
of draft and if necessary, seek
expert advice.
pins. See diagram 1.
5) Place the front log in the front of the unit,
aligningtheholesontheundersideofthelog
with the log support pins in the front of the
unit. Carefully push the log down onto the
pins. See diagram 1.
To reset the thermally actuated safety switch,
let the unit cool for 10 minutes, then press the
red reset button on the back of the switch. See
Diagram below.
Diagram 1
6) Place the cross logs on top of the larger logs
aligning the holes on the underside of the
cross log with the log pins in the larger logs.
See diagrams 1 & 2. Carefully push the
cross logs onto the pins.
TEST FOR FLUE
SPILLAGE
This heater must be properly connected to a
venting system.
LOG SET
INSTALLATION
WARNING:Operationofthisheater
when not connected to a properly
installed and maintained venting
system or tampering with the vent
safety shutoff system can result in
carbon monoxide (CO) poisoning
and possible death.
WARNING: Dangerous operating
conditions may occur if these logs
arenotpositionedintheirapproved
locations. Read the instructions
below carefully and refer to the
diagrams. If logs are broken do not
use the unit until they are replaced.
Broken logs can interfere with the
pilot and burner operation.
Diagram 2
7) Distribute the embers along the mesh em-
ber tray, but do not cover the burner ports.
(Burner ports are the little holes on the top
of the burner tube.) Pull off ember size
pieces from the rock wool. Gently place the
pieces on top of the embers. See diagram
3.
A “spillage” test must be made before the
installed unit is left with the customer. Follow
the procedure below:
Regency CLASSIC C33-2 Freestanding Gas Stove
11
INSTALLATION
Do not put the rock wool directly on the
burner. Close the door and turn the unit on
as per lighting instructions. Watch the
flame to see if it flows smoothly around
from one end to the other. (Use Extreme
Caution and ensure proper light off of
burner.)
OPTION 1: REMOTE
CONTROL
OPTION 3: WALL
THERMOSTAT
INSTALLATION
INSTALLATION
Can be used with Options 1 or 2
but not both.
Can be used with Options 2 or 3
but not both.
Regency offers an optional programmable ther-
mostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
UsetheRegencyRemoteControlKitapproved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
Connect the wires as per the wiring diagram.
Use the Thermostat Wire Table to determine the
maximum wire length.
1) Choose a convenient location on the wall
to install the receiver (protection from
extreme heat is very important). Run
wiresfrom the fireplace to that location.
Use the Thermostat Wire Table.
CAUTION
Do not wire millivolt wall thermo-
stat wires to the 120V AC wires
Note: Preferable if the thermostat is in-
stalled on an interior wall.
Diagram 3
2) Connect the two wires to the gas valve.
8) If the flame hesitates at any point, check the
area of hesitation and see if there is an
ember or rock wool blocking a burner port
or ports. If so, move the obstruction and
then check the flame flow again.
See diagram below.
Thermostat Wire Table
CAUTION
Do not wire millivolt remote
control wires to the
120V AC wires
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
SAFETY LATCH
3) Install 3 AAA alkaline batteries in transmit-
ter and 4 AA alkaline batteries in the
receiver. Install the receiver and its cover
in the wall. Switch the remote receiver to
"remote" mode. The remote control is now
ready for operation.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Securedoorintheclosed
position using the door
securingbracketandthe
screw provided.
Note: Door securing
OPTION 2: REMOTE
WALL SWITCH
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
Can be used with Options 1 or 3
but not both.
1) Runthewirethroughtheopeningintherear
of the unit. Be careful not to damage any
wires.
1) Clockingtheappliancetoensurethecorrect
firing rate (rate noted on label) after 15
minutes.
bracket is there for
safety.
Note: The door must be kept closed at all
times, except during maintenance.
The unit must never be operated
without the glass in the door, or
with the door open.
Note: We recommend a maximum of 15'
of wire but if you wish to go with
a longer run use the Thermostat
Wire Table.
2) If required, adjusting the primary air to en-
sure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
2) Connect the wire to the wall switch and
CAUTION: Any alteration to the product that
causes sooting or carboning that results in
damagetotheunitisnottheresponsibilityofthe
manufacturer and will not be covered by the
warranty.
install into receptacle box.
DOOR HANDLE
CAUTION
Attach spring handle by rotating counter clock-
wise onto rod.
Ensure that the
spring fits into the
entire length of the
Do not wire millivolt
wall switch for gas
appliance to the
120V AC wires
rod.
12
Regency CLASSIC C33-2 Freestanding Gas Stove
INSTALLATION
WIRING DIAGRAM
Thisheaterdoesnotrequirea120VA.C. supply
for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
CAUTION: Label all wires prior to
disconnectionwhenservicingcon-
trols. Wiring errors can cause im-
proper and dangerous operation.
WARNING:ElectricalGroundingInstructions
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be
pluggeddirectlyintoaproperlygroundedthree-prongreceptacle. Donotcutorremovethegroundingprongfromthisplug.
NORMAL OPERATING SOUNDS OF GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly
normal due to the fact that there are various
gauges and types of steel used within your
appliance. Listed below are some examples.
All are normal operating sounds and should
not be considered as defects in your appliance.
Burner Tray:
Pilot Flame:
Whilethepilotflameisonitcanmakeavery
slight "whisper" sound.
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a
different gauge material from the rest of the
firebox and body. Therefore, the varying thick-
nesses of steel will expand and contract at
slightly different rates which can cause "tick-
ing" and "cracking" sounds. You should also
be aware that as there are temperature chang-
es within the unit these sounds will likely re-
occur. Again, this is normal for steel fireboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF,
a dull clicking sound may be audible, this is
normal operation of a gas regulator or
valve.
Blower:
Regency gas appliances use high tech blow-
ers to push heated air farther into the room. It
is not unusual for the fan to make a "whirring"
sound when ON. This sound will increase or
decrease in volume depending on the speed
setting of your fan speed control.
Unit Body/Firebox:
Different types and thicknesses of steel
will expand and contract at different rates
resulting in some "cracking" and "ticking"
sounds will be heard throughout the cy-
cling process.
Blower Thermodisc:
When this thermally activated switch turns ON
itwillcreateasmall"clicking"sound. Thisisthe
switch contacts closing and is normal.
Regency CLASSIC C33-2 Freestanding Gas Stove
13
OPERATING INSTRUCTIONS
MAINTENANCE
INSTRUCTIONS
OPERATING
INSTRUCTIONS
LIGHTING
PROCEDURE
1) Always turn off the gas valve before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year.
1) The FIRST FIRE in your stove is part of the
paint curing process. To ensure that the
paint is properly cured, it is recommended
that you burn your fireplace for at least four
(4) hours the first time you use it with the
fan on. When first operated, the unit will
release an odour caused by the curing of
the paint and the burning off of any oils
remaining from manufacturing. Smoke de-
tectors in the house may go off at this time.
Open a few windows to ventilate the room
for a couple of hours. The glass panel may
require cleaning.
IMPORTANT: Gas cock knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
1) Turn burner OFF using "ON/OFF" switch.
When cleaning the logs, use a soft clean
brush as the logs are fragile and easily
damaged.
2) Turn gas control knob so indicator points to
"OFF" position and allow 5 minutes for any
gas in the combustion chamber to escape.
2) Cleanapplianceanddoorwithadampcloth
(never when unit is hot). Never use an
abrasive cleaner. The glass should be
cleaned with a gas fireplace glass cleaner
(when it starts to cloud up).
3) Turn gas control knob counterclockwise so
indicator points to the "PILOT" position.
Depress the gas control knob fully. De-
press the igniter button several times until
the pilot lights. After approximately one
minute, release the gas control knob. The
pilot flame should continue to burn. If the
pilot does not remain lit, repeat operation
allowing a longer period before releasing
gas control knob.
Do Not Attempt To Clean The Glass
While it is still hot!
3) The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint. Regency uses Stove
Brite Paint - Metallic Black #6309.
Note: When the glass is cold and the
appliance is lit, it may cause con-
densation and fog the glass. This
condensation is normal and will
disappear in a few minutes as the
glass heats up.
4) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making
sure the flames are steady; not lifting or
floating. Ifthereisaproblem, callaqualified
service person.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON" posi-
tion.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
5) Use the ON/OFF switch, wall switch, ther-
mostat or remote control to turn on the unit.
5) The appliance and venting system must be
inspected before use, and at least annual-
ly, by a qualified field service person, to
ensure that the flow of combustion and
ventilation air is not obstructed.
6) Rotate the flame height regulator (Hi/Lo) to
2) Read and understand these instructions
adjust the flame height higher or lower.
before operating this appliance.
3) Check to see that all wiring is correct and
enclosed to prevent possible shock.
SHUTDOWN
PROCEDURE
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers and rock
wool.
4) Check to ensure there are no gas leaks.
5) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
1) Use the "ON/OFF" switch, wall switch,
thermostat or remote control to turn off the
burner.
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This
condensation is normal and will disappear
in a few minutes as the glass heats up.
6) Verify that the venting is unobstructed.
2) Push in the PILOT knob slightly and turn
7) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs have
been incorrectly positioned.
clockwise to "OFF". Do not force.
7) Caution: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous oper-
ation. Verify proper operation after serv-
icing.
3) Turn off all electric power to the appliance
if service is to be performed.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait for purging.
WARNING: CHILDREN AND
ADULTSSHOULDBEALERTEDTO
THEHAZARDSOFHIGHSURFACE
TEMPERATURES AND SHOULD
STAYAWAYTOAVOIDBURNSOR
CLOTHING IGNITION. YOUNG
CHILDRENSHOULDBECAREFUL-
LYSUPERVISEDWHENTHEYARE
IN THE SAME ROOM AS THE AP-
PLIANCE.
14
Regency CLASSIC C33-2 Freestanding Gas Stove
OPERATING INSTRUCTIONS
COPY OF THE LIGHTING PLATE INSTRUCTIONS
FORYOURSAFETYREADBEFORELIGHTING
This appliance must be installed in accordance with local codes, if any; if not,
follow the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261)
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causingpropertydamage,personalinjuryorlossoflife.Improperinstallation,adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to the
owner’s information manual provided with this appliance. For assistance or additional
information consult a qualified installer, service agency or gas supplier.
A) This appliance has a pilot which must be lighted
by hand, following the instructions below
exactly.
B) BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.
a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any gas control which has
been under water.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
This appliance needs fresh air for safe operation and
must be installed so there are provisions for adequate
combustion and ventilation air.
- Do not touch any electric switch, do not use any
phone in your building
- Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier’s in-
structions.
CAUTION:Hotwhileinoperation. Donottouch.
Severe Burns may result. Due to high surface
temperatures keep children, clothing and
furniture, gasoline and other liquids having
fammablevaporsaway.Keepburnerandcontrol
compartment clean. See installation and
operatinginstructionsaccompanyingappliance.
- If you cannot reach your gas supplier, call the
fire department.
C) Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it, call
LIGHTINGINSTRUCTIONS
STOP! Read the safety information above on this
label.
1) Push in gas control knob slightly and turn
Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 3) and 4).
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn the
gas control knob to “OFF” and call your service
technician or gas supplier.
clockwise
to “OFF”. Knob cannot be turned
from “PILOT” to “OFF” unless knob is pushed in
slightly. Do not force.
2) Wait five (5) minutes to clear out any gas. If you
then smell gas STOP! follow “B” in the safety
information above on this label. If you don’t smell 5) Turn gas control knob counterclockwise
to “ON”.
gas, go to the next step.
6) Use rocker switch to operate main burner.
3) Turn knob on gas control counterclockwise
to “PILOT”.
PILOT BURNER
VEILLEUSE
OFF
4) Push in control knob all the way and hold in.
Immediately push black button on spark igniter
until pilot lights. Continue to hold the control
knob in for about 1/2 minute after the pilot is lit.
THERMOPILE
ELEMENT
THERMO-
ELECTRIQUE
TO TURN OFF GAS APPLIANCE
1) Push in the gas control knob slightly and turn 2) Turn off all electric power to the appliance if
clockwise to “OFF”. Do not force. service is to be performed.
You may shut off the pilot during prolonged non use periods to conserve fuel.
908-649a
DO NOT REMOVE THIS INSTRUCTION PLATE
Regency CLASSIC C33-2 Freestanding Gas Stove
15
MAINTENANCE
CAUTION:ANYSAFETYSCREEN
ORGUARDREMOVEDFORSERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERAT-
INGTHEAPPLIANCE.
THERMOPILE/
THERMOCOUPLE
PILOT ADJUSTMENT
Periodically check the pilot flames. Cor-
rect flame pattern has three strong blue
flames: 1 flowing around the thermopile,
1 around the thermocouple and 1 flowing
across the burner (it does not have to be
touching the burner).
1) Loosen the thermocouple or thermopile
with a 7/16" wrench at bracket.
2) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws
marked TP on the valve.
CLOTHING OR OTHER FLAMMA-
BLEMATERIALSHOULDNOTBE
PLACEDONORNEARTHEAPPLI-
ANCE.
Note: If you have an incorrect flame pat-
tern, contact your Regency dealer
for further instructions.
3) Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
NEVEROPERATETHEAPPLIANCE
WITHOUTTHEGLASSPROPERLY
SECUREDINPLACE.
4) Reinstall the new ones in reverse order.
AERATION
ADJUSTMENT
GENERAL VENT
MAINTENANCE
The aeration adjustment rod is attached to the
air shutter on the burner. The air shutter adjust-
ment rod is located under the ashlip on the right
side. The rod is used to adjust the aeration on
the burner. This adjustment is performed by the
installer and is primarily used in installations at
high elevations. Push the rod in for a yellow
flame, or pull out on the rod for a bluer flame.
Top View of pilot flame
Conduct an inspection of the venting system at
least annually. Recommended areas to inspect
are:
Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear burner or
thermopile or thermocouple.
1) Check areas of the Venting System which
are exposed to the elements for corrosion.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
Air shutter opening:
Natural Gas 7/16"
Propane
Wide open
2) Remove the Cap, and shine a flashlight
down the Vent. Remove any birds nests, or
other foreign material.
3) Check for evidence of excessive conden-
sation, such as water droplets forming in
the liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and fittings. It may
be caused by having excessive lateral
runs, too many elbows, or exterior portions
of the system being exposed to cold weath-
er.
Top View of pilot flame
4) Inspect joints, to verify that no pipe sections
or fittings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps for rigidity.
Closed - Tall Yellow flame
Open - Short Blue flame
Caution: Carbon will be produced if air
shutter is closed too much.
Note: Aeration Adjustment should only
be performed by an authorized
Regency Installer at the time of
installation or service.
16
Regency CLASSIC C33-2 Freestanding Gas Stove
MAINTENANCE
7) Installthereplacementglass.Whenplacing
the replacement glass in the door, make
sure that the glass gasketing will properly
seal your unit.
LOG REPLACEMENT
GLASS
REPLACEMENT
The unit should never be used with broken
logs. Turn off the gas valve and allow the unit
to cool before opening door to carefully re-
movethelogs.Thepilotlightgeneratesenough
heat to burn someone.
Your CLASSIC stove is supplied with high
temperature, 5 mm Neoceram ceramic glass
that will withstand the highest heat that your
unit will produce. In the event that you break
your glass by impact, purchase your replace-
ment glass from an authorized Regency dealer
only, and follow our step-by-step instructions
for replacement.
8) Put glass in place and then position glass
retainer rod.
Note: Do not use substitute materials. If
your glass does break, do not
continue to use your unit until it
has been replaced.
If for any reason a log should need replace-
ment,useonlyRegencyreplacementlogs.The
position of these logs must be as shown in the
diagram under Log Installation.
9) Position the glass retainer clips and door
securing bracket. Secure the glass retain-
ing screws but do not overtighten as this
may cause the glass to break after the unit
heats up.
1) Allow the stove to cool before removing or
NOTE: Improper positioning of logs may
create carbon build-up and will
alter the unit’s performance
which is not covered under war-
ranty.
replacing glass.
2) To remove the door from the stove remove
the securing screw located between the
ashlip and the door, then unfasten the latch.
10) Tighten all screws evenly.
3) Remove gold hinge caps from door.
4) Lift door off hinge.
Note: Do not overtighten as this may
cause breakage.
GOLD-PLATED DOORS
The 24 carat gold plated finish on the door
requires little maintenance, and need only be
cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the finish and void the warran-
ty. Clean any fingerprints off before
turning the unit on.
11) Slip door over hinge pins.
5) Lay door on a soft, flat surface.
12) Put hinge caps back onto door.
6) Remove the screws in the glass retainer
clips and remove the glass retainer rod.
Remove any remaining pieces of glass and
ensure that the door is free of debris. Use
caution when removing broken glass to
avoid injury.
13) Close door and secure the security bracket
with the screw.
Regency CLASSIC C33-2 Freestanding Gas Stove
17
MAINTENANCE
REMOVING VALVE
ASSEMBLY
1) Shut off gas supply.
2) If optional fan is installed, disconnect pow-
er source to stove.
3) Remove access panel.
a) Front panel on pedestal model. See
diagram 1.
b) Panel from bottom of leg shield. See
diagram 2.
Note: Access panel only has to be loos-
ened to be taken out.
16) Remove inlet pipe with pipe wrench. Note
8) If optional fan is installed, remove thermo-
disctobracketbyremovingthree(3)phillips
head M5 screws.
orientation of 90o elbow.
17) Remove two (2) phillips head M5 screws on
each side of the valve.
9) Remove front cover with Piezo Igniter by
removing two (2) sheet metal screws.
18) Remove valve and remove gas out 90o
brass fitting. Note orientation of fitting.
10) Loosen four (4) phillips head M5 valve
mounting screws from underside of fire-
box. Push valve assembly forward on the
teardrop slots and drop down. Diagram 3.
INSTALLING VALVE
ASSEMBLY
Diagram 1
1) To install a new valve assembly, reverse
instructions for removing valve. See
assembly steps 1-11.
2) Checkforleaksandmanifoldpressure. See
Gas Pressure Test instructions.
3) To reinstall valve, reverse instructions for
removing valve assembly, steps 12-18.
Diagram 3
11) Disconnect Piezo wire.
To remove valve from valve assembly,
continue.
Diagram 2
12) Remove two (2) thermopile wires.
4) Disconnect gas line to stove.
13) Remove thermocouple with a 9 mm (met-
5) Disconnect3/8"NPTpipefrom90o elbowon
ric) wrench.
valve.
14) Remove pilot nut with an 11 mm wrench.
6) Disconnect the two (2) switch wires from
valve.
15) Remove valve to orifice nut with a 13/16"
wrench.
7) Remove two (2) orifice bracket screws
inside firebox.
18
Regency CLASSIC C33-2 Freestanding Gas Stove
PARTS LIST
MAIN ASSEMBLY
Part #
Description
1)
846-913
846-915
Door Assy-Gold (no glass)
Door Assy-Black (no glass)
3)
4)
5)
6)
7)
9)
846-302
936-243
846-920
*
948-170/P
846-973
Small Glass
Glass Gasket (7/8")
Glass Retainer Clips (8/set)
Screw 1/4 - 20 x 3/8"
Small Glass Retainer
Door Handle/Latch Assembly
Spill Switch
7/8" Gasket Repair Kit
Hinge Cap - Gold (2/set)
Screw #10 - 24 x 3/4"
1/4" split lock washer
Screw #10 - 24 x 1/2"
Door Retainer Clip
10) 910-250
12) 846-570
13) 846-918
14)
15)
16)
*
*
*
17) 471-031
19) 948-101
Spring Handle - Large
490-917
20) 910-157/P
22) 910-794
910-140
Fan Assembly (120 V) Optional
Fan motor (120 V)
Power Cord
Fan HI/OFF/LOW switch
Fan Auto ON/OFF Thermodisc
28) 910-142
41) 460-006
908-636
RearPanel
Manual
*Not available as a replacement part.
Regency CLASSIC C33-2 Freestanding Gas Stove
19
PARTS LIST
BURNER & LOGS
Part #
Description
52) 910-190
Piezo Ignitor & Nut
ControlPanel
53)
*
908-672
Control Panel Decal
462-560/P
462-561/P
63) 910-378
910-380
Valve Assembly - S.I.T. - NG
Valve Assembly - S.I.T. - LP
Valve S.I.T. - NG
Valve S.I.T. - LP
66) 910-034
910-035
67) 904-604
904-390
Pilot Assembly-3 flame-S.I.T. -NG
Pilot Assembly-3 flame-S.I.T. -LP
Orifice #36 (NG)
Orifice #52 (LP)
68) 948-279
69) 948-294
70) 948-232
Burner - LP
Burner - NG
Air Shutter Adjusting Rod
*
*
Burner Tray Assy-NG
Burner Tray Assy-LP
Deflector - Front Log
Deflector - Rear Burner Front
Deflector - Btm
72) 490-023
73) 460-009
74) 490-025
Burner/Rear Log (LP)
Rear Log Deflector Top
- Propane
Deflector - Rear Burner
Back (NG)
75) 490-068
79) 460-011
80) 902-180
81) 902-186
82) 902-182
Front Log
Rear Log
Top Log (each)
93) 904-537
3/8 x 12" black mall nipple.
*Not available as a replacement part.
20
Regency CLASSIC C33-2 Freestanding Gas Stove
PARTS LIST
BASE OPTIONS
Part #
Description
Part #
Description
490-926
100) 948-216
102) 904-257
CompletePedestal
Regency Logo
Magnetic Catch (Large)
11" Pedestal Hinge
490-921
100) 948-216
102) 904-257
CompleteFloorShield
Regency Logo
Magnetic Catch (Large)
11" Pedestal Hinge
103)
*
103)
*
108) 910-246
109) 910-272
Burner ON/OFF Switch (2-way)
LT.DummyPlug
108) 910-246
109) 910-272
Burner ON/OFF Switch (2-way)
LT.DummyPlug
110)
123)
124) 820-058
125)
*
*
Strain Relief for power cord
PedestalBlankingPlate
Pedestal Cover Plate
110)
121)
*
*
Strain Relief for power cord
Access Panel
*
Rear Cover Plate
140) 850-126
850-127
Cast Legs - Black
Cast Legs - Gold
Cast Legs - Brush Nickel
Steel Legs
*Not available as a replacement part.
850-128
142) 850-125
Regency CLASSIC C33-2 Freestanding Gas Stove
21
NOTES
_____________________________________________________________________________________
____________________________________________________________
__________________________________________________________
____________________________________________________________
_______________________________________________________
_____________________________________________________
__________________________________________________________
_________________________________________________________
_________________________________________________________
______________________________________________________
______________________________________________________
_______________________________________________________________
___________________________________________________________
__________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
_____________________________________________________________
__________________________________________________________
__________________________________________________________
_____________________________________________________
________________________________________________________
_________________________________________________________
_________________________________________________________
22
Regency CLASSIC C33-2 Freestanding Gas Stove
WARRANTY
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each
unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original
purchaser of a Regency Product. This warranty is not transferable.
The Warranty: Limited Lifetime
The combustion chamber, heat exchanger, burner tubes/pans, logs and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty
for five (5) years for parts and subsidized labour* and parts only thereafter.
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.
Special Finishes - One year on brushed nickel, louvers and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI
warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie. finger
prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly
components, and gas valves are covered for one year parts and subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered
repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date
of replacement.
FPI venting components (Direct Vent units) are covered parts and subsidized labour* for three (3) years from date of purchase.
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent
provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated
for manufacturer defect.
The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship
from unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the field which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer
name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
AtnotimewillFPIbeliableforanyconsequentialdamageswhichexceedthepurchasepriceoftheunit.FPIhasnoobligationtoenhanceormodifyanyunitoncemanufactured.
ie. as products evolve, field modifications or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers, glass and door gaskets, door handles and paint are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
Thewarrantywillnotextendtoanypartwhichhasbeentamperedwithoralteredinanyway, orinourjudgmenthasbeensubject tomisuse, improperinstallation, negligence
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryer, etc.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Regency, may nullify
your warranty on this product.
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.
* Subsidy according to job scale as predetermined by FPI.
Regency CLASSIC C33-2 Freestanding Gas Stove
23
Regency fireplace products are designed
with reliability and simplicity in mind. In
addition,ourinternalQualityAssurance
Teamcarefullyinspectseachunitthor-
oughly before it leaves our door.
Fireplace Products International
Ltd. is pleased to extend this
LimitedLifetimeWarrantytotheorig-
inal purchaser of a Regency Product.
See the inside back cover for details.
Register your Regency online at
Installer:Pleasecompletethefollowinginformation
Dealer Name & Address:______________________________________________
__________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: _________________________________________________________
Regency and Classic are trademarks of FPI Fireplace Products International Ltd.
© Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved.
Printed in Canada
|
QSC Audio Portable Speaker MD FP122 94r User Guide
Radio Shack Scanner PRO 99 User Guide
Ratoc Systems Computer Drive SMA03U User Guide
Renesas Computer Hardware R0E571490CFJ00 User Guide
Riccar Sewing Machine REC 5900 User Guide
Samsung Computer Drive HS08XJF User Guide
Samsung Digital Photo Frame SPF 72H User Guide
Samsung Home Theater System AH68 02269K User Guide
Sanyo Digital Camera VCC PN9575P User Guide
SECO LARM USA Power Supply EV 1223B12 User Guide