Cooper Lighting Indoor Furnishings UMX Series User Manual

®
COOPER LIGHTING - SURE-LITES  
DESCRIPTION  
Type  
The Sure-Lites watertight, corrosion resistant exit with tough polycarbonate  
lens is designed for use where rain, moisture, dust or corrosives are  
present. Economical long-life fluorescent lamps provide highly visible  
signage and downlighting. The vibration resistant lamps make the UMX  
perfect for heavy industrial applications (NEMA 4X Listed).  
Catalog #  
Project  
Date  
Comments  
Prepared by  
SPECIFICATION FEATURES  
Electronic  
Housing Construction Cont.  
- Tough, high contrast  
polycarbonate lens  
Code Compliance  
- Dual Voltage Input  
120/277 VAC, 60 Hz  
- Line-latching  
- UL 924 Wet Location Listed  
- Life Safety NFPA 101  
- NEC/OSHA  
- Rubber booted momentary  
test switch and gasketed  
charge indicator lamp  
- Surface mount only  
- Fully gasketed housing  
- Wet Location Listed for  
operation in ambient  
temperatures above  
- Solid-state Voltage  
Limited Charger  
- Most State and Local Codes  
Warranty  
- Exit: 1-year  
- Solid-state Switching  
- Brownout Circuit  
- Low-Voltage Disconnect  
- Overload/Short Circuit  
Protection  
- Battery: 5-year pro-rata  
(Lead Calcium); 15-year  
pro-rata (Nickel Cadmium)  
- Sealed Test Switch/Power  
Indicator Light  
32 degrees F.  
Lamp Data  
- AC: Two F6T5 fluorescent lamps  
- DC: Two 6V, 6W DC lamps  
- Long-life, low energy  
consumption  
Battery  
UMX  
SERIES  
Housing Construction  
- NEMA 4X corrosion  
resistant fiberglass  
housing  
- 6 Volt Sealed Lead Calcium  
or Sealed Nickel Cadmium  
- Maintenance-Free, Long-Life  
- Full Recharge Time  
24 hrs. (max.)  
- Available with emergency  
lighting heads mounted on  
enclosure - consult Cooper  
Lighting Representative  
- Industrial grey color  
- Vented enclosure  
WET LOCATION EXITS  
SELF-POWERED  
EMERGENCY FLUORESCENT  
LAMPS  
Exit Lighting  
11 3/4"  
[298mm]  
ENERGY DATA  
Charge Mode (Fully Discharged Battery)  
Sealed Lead Calcium Battery  
Fluorescent Exits - 6W Lamps  
Input Power:  
120V= 41W  
277V= 43W  
Input Current (Max.):  
120V= .51A  
7 1/2" [191mm]  
11 3/4" [298mm]  
277V= .22A  
Power Factor:  
120V= >.66  
277V= >.69  
T.H.D.:  
120V= <14%  
277V= <14%  
Standby Mode (Fully Charged Battery)  
Sealed Lead Calcium Battery  
Sample Number: UMX203  
Input Power consumption is reduced by  
approximately 18 Watts in the standby  
operating mode.  
Sealed Nickel Cadmium Battery  
Fluorescent Exits - 6W Lamps  
Input Power:  
Series  
Letter Color / Arrow  
Direction  
Options  
=Dual Heads  
DH  
Accessories  
Protective Housing  
=Self-Powered Wet  
Location with  
Fluorescent  
Lamps  
UMX  
=Red Letters / Right Arrow  
Wire Guard  
=
WG7  
8
120V= 29W  
Polycarbonate Vandal Shield  
VS2  
=Red Letters / No Arrow  
=
7
277V= 29W  
Polycarbonate Vandal Shield -  
=
Weather Proof  
VS2WP  
=Red Letters / Left Arrow  
=Red Letters / Double Arrow  
=Green Letters / Right Arrow  
=Green Letters / No Arrow  
=Green Letters / Left Arrow  
6
5
4
3
2
1
Input Current (Max.):  
120V= .42A  
Battery  
=Self-Powered, Lead  
Calcium  
20  
277V= .17A  
Power Factor  
=Lead Calcium Battery  
w/Remote Capability  
10  
120V= >.57  
=Green Letters / Double  
Arrow  
277V= >.62  
=Self-Powered, Nickel  
Cadmium  
22  
T.H.D.:  
120V= <9%  
277V= <38%  
Specifications and Dimensions subject to change without notice.  
ADX041112  
10/02/2008 9:07:48 AM  
Consult your representative for additional options and finishes.  
 
UMX EXITS  
WATTAGE RATINGS  
UMX201 – UMX208 Lead Calcium=18W for 1 1/2 hrs.; 15W for 2 hrs.  
UMX101 – UMX108 Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs.  
UMX221 – UMX228 Nickel Cadmium=15W for 1 1/2 hrs.; 12W for 2 hrs.  
TECHNICAL DATA  
Lamps  
Solid-State Charger  
Brownout Circuit  
Sealed Lead Calcium Battery  
Two F6T5 fluorescent lamps  
provide long life and normal  
mode illumination of the  
lens. Two 6V, 6W DC lamps  
illuminate the face panel in  
the emergency mode.  
Supplied with a 120/277 VAC,  
voltage regulated solid-state  
charger. Immediately upon  
restoration of AC current after  
a power failure, the charger  
provides a high charge rate.  
The charge circuit reacts to the  
condition of the battery and  
alters the rate of charge in  
order to maintain peak battery  
capacity and maximize battery  
life. Solid-state construction  
recharges the battery following  
a power failure in accordance  
with UL 924.  
The brownout circuit on Sure-  
Lites’ exits monitors the flow  
of AC current to the exit and  
activates the emergency  
The fully sealed, long-life,  
maintenance-free, lead calcium  
battery is ideal for emergency  
lighting applications. These  
batteries typically provide 8 to  
10 years of life and may be  
operated in any position.  
lighting system when a  
predetermined reduction of  
AC power occurs. This dip  
in voltage will cause most  
ballasted fixtures to extinguish  
causing loss of normal lighting  
even though a total power  
failure has not occurred.  
Housing Construction  
Sealed Nickel  
Cadmium Battery  
The Sure-Lites UMX Series  
incorporates a rugged  
Sure-Lites’ sealed nickel  
cadmium batteries are  
enclosure of moisture and  
corrosion resistant industrial  
grey fiberglass with a durable  
polycarbonate lens. Housing  
is fully gasketed. A breather  
vent permits ventilation of  
internal pressure from gases  
released by charging batteries.  
UMX Series Exits are suitable  
for surface mounting only. Wet  
Location Listed for operation in  
ambient temperatures above  
32°F. Optional Thermal Heater  
available to facilitate use  
maintenance-free with a life  
expectancy of 15 years. The  
sealed rechargeable nickel  
cadmium battery offers high  
discharge rates and stable  
performance over a wide range  
of temperatures. The specially  
designed resealable vent  
automatically controls cell  
pressure, assuring safety and  
reliability. This battery is best  
suited for harsh ambient  
Solid-State Transfer  
The UMX Exit incorporates  
solid-state switching which  
eliminates corroded and pitted  
contacts or mechanical failures  
associated with relays. The  
switching circuit is designed to  
detect a loss of AC voltage and  
automatically energizes the  
lamps. Upon restoration of  
AC power, the emergency  
lamps will switch off and the  
charger will automatically  
recharge the battery.  
Overload and Short  
Circuit Protection  
The solid-state overload  
monitoring device in the DC  
circuit disconnects the lamp  
load from the battery should  
excessive wattage demands  
be made and automatically  
resets when the overload or  
short circuit is removed. This  
overload current protective  
feature eliminates the need  
for fuses or circuit breakers  
for the DC load.  
temperatures because the  
electrolyte is not active in the  
electrochemical process.  
in unheated areas where  
battery performance would  
be diminished due to low  
temperature operation.  
Warranty  
Test Switch/Power Indicator  
Light  
Line-Latched  
All Sure-Lites’ products are  
backed by a firm one-year  
warranty against defets in  
material and workmanship  
(excluding lamps). Maintenance-  
Conveniently located rubber  
booted Test Switch allows for  
manual verification of proper  
operation of the transfer circuit  
Sure Lites’ line-latched  
electronic circuitry makes  
installation easy and  
economical. A labor efficient  
AC activated load switch  
prevents the lamps from turning  
on during installation to a  
non-energized AC circuit.  
Line-latching eliminates the  
need for a contractor’s return  
to a job site to connect the  
batteries when the building’s  
main power is turned on.  
and emergency lamps. A sealed free, long-life, sealed lead  
light emitting diode (Power  
Indicator Light) provides visual  
assurance that the AC power  
is on.  
calcium batteries carry a  
five-year, pro-rata warranty.  
Maintenance-free, long-life,  
sealed nickel cadmium batteries  
carry a fifteen-year pro-rata  
warranty.  
Specifications and Dimensions subject to change without notice.  
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801  
ADX041112  
10/02/2008 9:07:48 AM  
 

Concord Camera Digital Camera 5330z User Manual
Cooper Lighting Landscape Lighting EGL91SW233 User Manual
Creative Labs Car Speaker T6100 User Manual
Dacor Griddle AEGR Grill User Manual
Directed Audio Car Amplifier 600 4 User Manual
Dynex Switch DX 4P2H User Manual
Dyson Vacuum Cleaner DC15 User Manual
EverFocus Car Video System MEN2G00200 User Manual
Garmin Carrying Case nvi 660 User Manual
GE Toaster 168958 User Manual