General: Upon receipt of fixture thoroughly inspect for any  
freight damage, which should be brought to the attention of  
the delivery carrier. Compare the catalog description listed  
on the packing slip with the fixture label on the housing to  
assure you have received the correct merchandise.  
Safety: This fixture must be wired in accordance with  
the national electrical code and applicable local codes  
and ordinance. Proper grounding is required to insure  
personal safety. Carefully observe grounding procedure  
under installation section. All work should be done by a  
qualified electrician.  
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing  
or servicing.  
ARM & FIXTURE INSTALLATION  
Bishop Arm  
Bishop Arm (VA6005-VA6008, VA6054-VA6057, VA6105-VA6108  
& VA6154-VA6157)  
See Figure 1.  
1. Secure arm onto pole and orient.  
2. Tighten the six set screws located near bottom of arm to  
150 in/lbs. to secure arm.  
Fixture Screws  
Teflon Washers  
Arm Cap  
3. Loosen the three arm cap set screws and remove arm cap.  
4. Pull fixture leads through arm to arm cap location.  
5. Raise fixture to arm aligning locating pin and socket.  
See Figure 2.  
Arm Cap  
Set Screws  
6. Insert and tighten 4 fixture screws with Teflon washers, provided  
in polybag, to 80 in/lbs.  
7. Connect fixture leads to service leads.  
8. Resecure arm cap with arm cap set screws tightened to  
50 in/lbs.  
Set Screws  
Fig. 1  
Traditional Arm (VA6009-VA6021 VA6058-VA6070,  
VA6109-VA6121 & VA6158-VA6170)  
See Figure 3.  
Modern Top  
1. Slip arm onto pole and orient.  
2. Tighten the six set screws located near bottom of arm to  
150 in/lbs. to secure arm.  
3. Loosen the three arm cap set screws and remove arm cap.  
4. Pull fixture leads through arm to arm cap location.  
5. Raise fixture to arm aligning locating pin and socket.  
See Figure 2.  
Aligning Pin  
Aligning Socket  
6. Insert and tighten 4 fixture screws with Teflon washers, provided  
in polybag, to 80 in/lbs.  
7. Connect fixture leads to service leads.  
8. Resecure arm cap with arm cap set screws tightened to  
50 in/lbs.  
Fig. 2a  
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible  
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for users purpose, please  
contact your nearest representative.  
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575 AVU040300  
 
TM  
Epic/Pole Mounted  
Fixtures  
Sheet 3 of 4  
INSTALLATION INSTRUCTIONS  
2/18/04  
IMI-575  
IMPORTANT: Read carefully before installing fixture. Retain for future reference.  
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing  
or servicing.  
Vertically lamped  
1. Loosen and remove ring retaining screws globe retaining ring  
and globe. Components are not tethered.  
See Figure 5.  
Options  
FG, FR, SG & FRS  
Fig. 4b  
2. Remove two screws on ballast cover followed by ballast  
cover. See Figure 7.  
3. Unplug optic quick-disconnect.  
4. For starter replacement, remove the plug-in starter from  
receptacle and replace.  
For fuse replacement, unscrew fuse holder cap and replace  
fuse. Resecure fuse holder cap.  
Tether  
5. Plug optic quick-disconnect.  
Door Screws  
6. Resecure the ballast cover with the two screws.  
7. Reinstall ring retaining screws securing globe retaining ring  
and globe. In the case of type 3 refractive glass globe, use the  
mark on globe bottom for orientation.  
Option MA  
C. Power Pack Replacement  
Horizontally lamped  
1. Loosen two door screws.  
2. Lower door to tethered resting position. See Figure 4.  
3. Loosen thumbscrew until rectangular washer can be rotated  
90 degrees. See Figure 6.  
4. Rotate reflector faceplate to release from screws using key  
hole slots.  
Ring Retaining Screws  
Globe Retaining Ring  
5. Unplug optic quick-disconnect.  
6. Remove two screws on ballast cover followed by ballast  
cover. See Figure 7.  
Fig. 5a  
Globe  
7. Unplug service quick-disconnect.  
8. Holding the handle, loosen the two screws holding the power  
pack to the fixture housing. See Figure 8.  
9. Holding the handle, rotate the power pack until free and lower.  
10. Holding replacement power pack by handle, raise onto screw  
heads and rotate.  
Options  
3R & 5R  
11. Tighten the two screws while holding power pack in position.  
12. Plug together the service quick-disconnect.  
13. Resecure the ballast cover with the two screws.  
14. Reconnect optic quick-disconnect and secure reflector by  
keyhole slots and thumbscrew.  
Ring Retaining Screws  
Globe Retaining Ring  
Globe  
15. Raise door and secure with screws.  
Fig. 5b  
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible  
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for users purpose, please  
contact your nearest representative.  
Customer First Center 1121 Hwy 74 South Peachtree City, GA 30269 IMI-575 AVU040300  
 
TM  
Epic/Pole Mounted  
Fixtures  
Sheet 4 of 4  
INSTALLATION INSTRUCTIONS  
2/18/04  
IMI-575  
IMPORTANT: Read carefully before installing fixture. Retain for future reference.  
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing  
or servicing.  
Vertically lamped  
1. Loosen and remove ring retaining screws globe retaining  
ring and globe. Components are not tethered.  
See Figure 5.  
Ballast Cover  
Screws  
2. Remove two screws on ballast cover followed by ballast  
cover. See Figure 6.  
Optic  
Quick-  
Disconnect  
3. Unplug optic quick-disconnect.  
4. Unplug service quick-disconnect.  
5. Loosen the two screws holding the power pack to the  
fixture housing. See Figure 7.  
6. Holding the power pack by the handle, rotate the power  
pack until free and lower.  
Fig. 7a  
7. Holding replacement power pack by handle, raise onto  
screw heads and rotate.  
8. Tighten the two screws while holding power pack in  
position.  
9. Plug together the service quick-disconnect.  
10. Plug together the optic quick-disconnect.  
11. Resecure the ballast cover with the two screws.  
12. Reinstall ring retaining screws securing globe retaining ring  
and globe. In the case of type 3 refractive glass globe, use  
the mark on globe bottom for orientation.  
Fuse  
Starter  
Handle  
Service  
Quick-Disconnect  
Fig. 7b  
Reflector  
Keyhole Slot  
Removal  
Rectangular Washer  
Thumbscrew  
Screws  
Fig. 6  
Fig. 8  
Power Pack Removal  
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible  
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for users purpose, please  
contact your nearest representative.  
Customer First Center 1121 Hwy 74 South Peachtree City, GA 30269 IMI-575 AVU040300  
 

Cobalt Networks TV Converter Box 9033 SD User Manual
Cooper Lighting Indoor Furnishings BIAX 40W User Manual
Curtis Speaker System CR1336 User Manual
Dacor Kitchen Utensil EWD24 User Manual
Edelbrock Camera Accessories 65732 User Manual
Fundex Games Games Paddle Pool User Manual
Fundex Games Games Phase 10 Masters Edition in Tin User Manual
Gaggenau Ventilation Hood AH 600 190 User Manual
Generac Power Systems Portable Generator 04758 0 User Manual
Global Technology Associates Kitchen Entertainment Center GB 2000X User Manual