PRACTICAL USER’S GUIDE
FOR THE SAHARA FIREPLACE
Model 6903950000 series
CAT NUMBER:
EWF-SS
Quality checked by:
Valued Customer,
We are pleased that you have chosen to purchase an electric
fireplace manufactured by Dimplex North America Limited.
7208570100R04
QUICK REFERENCE GUIDE FOR THE SAHARA
FIREPLACE
1. Before using the Sahara fireplace verify:
·
Are the circuit breakers for the unit
on?
·
Are the light bulbs loose? (to
check, follow the instructions for
replacing the light bulbs under the
maintenance section of this
manual)
2. The heater may emit a slight, harmless
odor when first used. This odor is a
normal condition caused by the initial
heating of internal heater parts.
3. The information regarding the model of
your unit can be found on the carton
label or the rating plate. The rating plate
is located on the side of the unit
underneath the outer frame. The carton
label is attached to the front surface of
the carton.
Serial Number Label
Rating Label
Serial NumberLabel
Rating
Label
4. If you have any questions or concerns
regarding the operation of your fireplace,
contact Dimplex customer service at 1-
888-DIMPLEX (1-888-346-7539).
IMPORTANT INSTRUCTIONS
RETAIN THIS USER’S GUIDE FOR FUTURE
REFERENCE
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons.
1. Read all instructions before using the Sahara
fireplace.
2. The heater is hot when in use. To avoid
burns, do not let bare skin touch hot
surfaces. The trim around the heater outlet
becomes hot during heater operation. Keep
combustible materials, such as furniture,
pillows, bedding, papers, clothes, and
curtains at least 3 feet (0.9m) from the front of
the unit.
3. Extreme caution is necessary when any
heater is used by or near children or invalids
and whenever the unit is left operating and
unattended.
4. Always unplug the Sahara fireplace when not
in use.
5. Do not operate with a damaged cord or plug,
or if the heater has malfunctioned, or if the
Sahara fireplace has been dropped or
damaged in any manner. Return heater to
authorized service facility for examination,
electrical or mechanical adjustment, or repair.
6. Do not use outdoors.
7. The Sahara fireplace is not intended for use
in bathrooms, laundry areas and similar
indoor locations. Never locate heater where
it may fall into a bathtub or other water
container.
1
8. Do not run the cord under carpeting. Do not
cover cord with throw rugs, runners, or the
like. Arrange cord away from traffic area and
where it will not be tripped over.
9. To disconnect the unit, turn the controls off,
then remove the plug from the outlet.
10.Do not insert or allow foreign objects to enter
any ventilation or exhaust opening as this
may cause an electric shock or fire, or damage
to the heater.
11. To prevent a possible fire, do not block air intake
or exhaust in any manner. Do not use on soft
surfaces, like a bed, where openings may
become blocked.
12. All electrical heaters have hot and arching or
sparking parts inside. Do not use in areas
where gasoline, paint, or flammable liquids are
used or stored or where the unit will be exposed
to flammable vapors.
13. Do not modify the Sahara fireplace . Use it only
as described in this manual. Any other use not
recommended by the manufacturer may cause
fire, electric shock or injury to persons.
14. To reduce the risk of electric shock, this
appliance must be grounded.
Avoid the use of an extension cord. Extension
cords may overheat and cause a risk of fire. If
you must use an extension cord, the cord must
be No. 16 AWG minimum size and rated no
less than 1875 watts.
15. Do not burn wood or other materials in the
Sahara fireplace.
16. Do not strike the glass front.
17. Always use a certified electrician should new
circuits or outlets be required.
18. Always use properly grounded, fused and
polarized outlets.
2
19. Disconnect all power supply before performing
any cleaning, maintenance or relocation of the
unit.
20. When transporting or storing the unit and cord,
keep in a dry place, free from excessive
vibration and store so as to avoid damage
21 If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a
hazard
22 The heater must not be located immediately
below a socket-outlet
SAVE THESE INSTRUCTIONS
NOTE: Procedures and techniques that are considered
important enough to emphasize.
CAUTION: Procedures and techniques which, if not carefully
followed, will result in damage to the equipment.
WARNING: Procedures and techniques which, if not
carefully followed, will expose the user to the risk of fire,
serious injury, illness or death.
NOTE
A 15amp, 120 volt circuit is required. A dedicated circuit is
preferred but not essential in all cases. A dedicated circuit
will be required if, after installation, the circuit breaker trips or
the fuse blows on a regular basis when the heater is
operating. Additional appliances on the same circuit may
exceed the current rating of the circuit breaker.
WARNING
Ensure the power cord is not installed so that it is
pinched or against a sharp edge and ensure that the
power cord is stored or secured to avoid tripping or
snagging to reduce the risk of fire, electric shock or
injury to persons.
Construction and electrical outlet wiring must comply
with local building codes and other applicable
3
regulations to reduce the risk of fire, electric shock
and injury to persons.
Do not attempt to wire your own new outlets or
circuits. To reduce the risk of fire, electric shock or
injury to persons, always use a licensed electrician.
WARNING
The supplied mounting bracket is designed for
use with Dimplex wall mounted fireplaces only.
Improper use, or use for purposes other than
intended, may cause damage or injury.
SAHARA FIREPLACE
INSTALLATION
WARNING
Failure to install the Sahara fireplace as instructed below may
result in damage to the equipment and or may expose the
user to the risk of fire, serious injury, illness or death.
WARNING
The Sahara fireplace requires the wall mounting bracket
screws to be installed into a minimum of two wall studs.
(FIGURE 1)
1. Select an appropriate location to mount the
unit on a wall, above an electrical outlet.
The bottom of the unit must be a minimum
of 12" above the floor (mounting bracket
34" above the floor). Access to the
electrical outlet must be maintained. Ensure
the installation meets the national and state/
provincial electrical codes.
4
Figure 1
NOTE: It is recommended that the bottom of the
unit not be mounted higher than 40" from the
ground (mounting bracket no higher than 62").
WARNING
Ensure the front of the installed unit will be at least 3
feet (0.9m) from combustible materials, such as
furniture, pillows, bedding, papers, clothes, and
curtains.
2. The wall-mounting bracket must be mounted
to at least two wall studs. Studs should be
accessed through two wall-bracket holes in
one of the following combinations: A&F,
B&D, or C&E (FIGURE 2).
Figure 2
NOTE: Wall anchors must be installed in the
appropriate wall locations to fasten the wall bracket
through the remaining holes (Figure 4). For
example, if you plan to secure the bracket to studs
through holesA&F, install anchors centered on
holes B, C, D, and E.
3. Hold the wall-mounting bracket on the wall and
mark the location of ONE of the mounting holes.
4. Place the bubble level onto the top of the wall-
mounting bracket.
5
5. Adjust the wall-mounting bracket so the bubble
on the level is centered between the two black
lines.
6. Mark 5 other mounting screw locations, on the
wall, ensuring that the wall bracket stays level.
7. Install the supplied wall anchors on the marked
locations by placing a #2 phillips screwdriver
into the recess of the anchor. Press the anchor
into the wall in the desired marked position
while turning the anchor clockwise until it is flush
with the wall
9. Insert the wall anchor screws through the wall
bracket and thread into the wall anchors.
Tighten the screw. (FIGURE 4)
10.Install the remaining screws through the bracket
and into the wall studs as required.
Note: At least two of the mounting screws
must be installed into a wall stud.
Wall Anchor
Screw
Wall Bracket
Figure 4
11. Remove glass assembly (Figure 5).
6
2
3
1
15.
Figure 5
12. Mount the unit on the wall as shown (Figure 6).
Wall Bracket Supports
Wall Bracket
Figure 6
13. Fix the unit in place by inserting 2 screws through 2 of
the 4 available back panel holes, and into the wall studs. If
studs are unattainable please use wall anchors. (Figure 7).
Figure 7
Panel Mounting Holes
17.Replace glass assembly.
7
OPERATION
The controls are located on the bottom surface of the Sahara
fireplace on the right side.
Front View
Control Location
Figure 8
Bottom View
C
A B
A. MAIN ON/OFF SWITCH
The switch has two ON positions marked with
and “Manual”.
The “Manual” position is for manual operation. In
this position the built-in remote control is by-passed.
The
position is for operating the unit with the
provided remote control.
When in
position the unit is operated with the
ON and OFF buttons of the remote control.
When the switch is in the center position the unit is
off.
B. HEATER ON SWITCH
The HEAT ON/OFF SWITCH supplies power to the
heater fan and the heater element. When the switch
is in the ON position the heater operates if the
thermostat calls for heat.
8
C. HEATER THERMOSTAT CONTROL
To adjust the temperature to your individual
requirements, turn the thermostat control clockwise
all the way to turn on the heater. When the room
reaches the desired temperature, turn the
thermostat knob counter clockwise until you hear a
click. Leave in this position to maintain the room
temperature at this setting. For additional heat, turn
clockwise until you hear the click again and the
heater will turn on.
RESETTING THE
TEMPERATURE CUTOFF
SWITCH
Should the heater overheat, an automatic cut out will
turn the heater off and it will not come back on
without being reset. It can be reset by switching the
MAIN ON/OFF SWITCH to OFF and waiting 5
minutes before switching the unit back on.
CAUTION
If you need to continuously reset the heater, unplug
the unit and call Dimplex customer service at 1-888-
DIMPLEX (1-888-346-7539).
9
REMOTE OPERATION
The Fireplace is supplied with an integrated on/off
remote control
Note: Ensure that the fireplace 3 position
switch is set to the remote Control setting. (Up
position)
To operate, push the ON button to turn fireplace on,
push the OFF button to turn the fireplace off.
BATTERY REPLACEMENT
To replace the battery, slide battery cover open on
the hand held transmitter. Correctly install one 12
volt (A23) battery in the battery holder.
Close the battery cover.
ON BUTTON
OFF BUTTON
BATTERY
BATTERY
COVER
Figure 9
10
MAINTENANCE
WARNING
Disconnect power before attempting any
maintenance or cleaning to reduce the risk of fire,
electric shock or damage to persons.
LIGHT BULB REPLACEMENT
Allow at least 5 minutes for light bulbs to cool before
touching bulbs to avoid accidental burning of skin.
Light bulbs need to be replaced when you notice a
dark section of the flame or when the clarity and
detail of the log exterior disappears. There are two
bulbs under the log set which generate the flames
and embers.
TOOL REQUIREMENTS
-None
HELPFUL HINTS
It is a good idea to replace all light bulbs at one time
if they are close to the end of their rated life. Group
replacement will reduce the number of times you
need to open the unit to replace light bulbs.
LOWER LIGHT BULB REQUIREMENTS
Quantity of 3 – 60W Chandelier or candelabra bulbs
with E-12 (small) socket base, 120 Volt.
DO NOT EXCEED 60-WATTS PER
BULB.
11
BULB REPLACEMENT INSTRUCTIONS:
1. Unplug the unit from the outlet.
2. Remove glass assembly as shown in figure 5.
3. Reach in and turn the burnt-out bulb(s) (or all
bulbs) counter-clockwise to remove.
4. Replace with new bulbs.
5. Fit glass assembly back in place.
6. Plug in the Sahara fireplace.
GLASS CLEANING
The front glass is cleaned in the factory during the
assembly operation. During shipment, installation,
handling, etc., the front glass may collect dust
particles, these can be removed by dusting lightly
with a clean dry cloth.
To remove fingerprints or other marks, the glass can
be cleaned with a damp cloth. The glass should be
completely dried with a lint free cloth to prevent
water spots. To prevent scratching, do not use
abrasive cleaners or spray liquids on the glass
surface.
SAHARA FIREPLACE SURFACE CLEANING
To remove fingerprints or other marks, the exterior
finish can be cleaned with a damp cloth with a mild
detergent. The surface should be completely dried
with a lint free cloth to prevent water spots.
To prevent scratching, do not use abrasive
cleaners or spray liquids on any surface.
12
TWO YEAR LIMITED
WARRANTY
Products to which this limited warranty applies
This limited warranty applies to the following models of your
newly purchased Dimplex electric fireplace EWF-SS and to
newly purchased Dimplex fireplace surrounds (mantels) and
trims. This limited warranty applies only to purchases
made in any province of Canada except for Yukon Territory,
Nunavut, or Northwest Territories or in any of the 50 States
of the USA (and the District of Columbia) except for Hawaii
and Alaska. This limited warranty applies to the original
purchaser of the product only and is not transferable.
Products excluded from this limited warranty
Light bulbs are not covered by this limited warranty and are
the sole responsibility of the owner/purchaser. Products
purchased in Yukon Territory, Nunavut, Northwest
Territories, Hawaii, or Alaska are not covered by this
limited warranty. Products purchased in these States,
provinces, or territories are sold AS IS without warranty or
condition of any kind (including, without limitation, any
implied warranties or conditions of merchantability or
fitness for a particular purpose) and the entire risk of as to
the quality and performance of the products is with the
purchaser, and in the event of a defect the purchaser
assumes the entire cost of all necessary servicing or
repair.
What this limited warranty covers and for how long
Products, other than fireplace surrounds (mantels) and trims,
covered by this limited warranty have been tested and
inspected prior to shipment and, subject to the provisions of
this warranty, Dimplex warrants such products to be free from
defects in material and workmanship for a period of 2 years
from the date of the first purchase of such products.
13
Dimplex fireplace surrounds (mantels) and trims covered by
this limited warranty have been tested and inspected prior to
shipment and, subject to the provisions of this warranty,
Dimplex warrants such products to be free from defects in
material and workmanship for a period of 1 year from the date
of first purchase of such products.
The limited 2 year warranty period for products other than
fireplace surrounds (mantels) and trims and the limited 1 year
warranty period for fireplace surrounds (mantels) and trims
also applies to any implied warranties that may exist under
applicable law. Some jurisdictions do not allow limitations on
how long an implied warranty lasts, so the above limitation
may not apply to the purchaser.
What this limited warranty does not cover
This limited warranty does not apply to products that have
been repaired (except by Dimplex or its authorized service
representatives) or otherwise altered. This limited warranty
does further not apply to defects resulting from misuse,
abuse, accident, neglect, incorrect installation, improper
maintenance or handling, or operation with an incorrect power
source.
What you must do to get service under this limited warranty
Defects must be brought to the attention of Dimplex Technical
Service by contacting Dimplex at 1-888-DIMPLEX (1-888-346-
7539), or 1367 Industrial Road, Cambridge Ontario, Canada
N1R 7G8. Please have proof of purchase, catalogue/model
and serial numbers available when calling. Limited warranty
service requires a proof of purchase of the product.
What Dimplex will do in the event of a defect?
In the event a product or part covered by this limited warranty
is proven to be defective in material or workmanship during (i)
the 2 year limited warranty period for products other than
fireplace surrounds (mantels) and trims, and (ii) the 1 year
limited warranty period for surrounds (mantels) and trims, you
have the following rights:
14
§
Dimplex will in its sole discretion either repair or
replace such defective product or part without
charge. If Dimplex is unable to repair or replace
such product or part, or if repair or replacement is
not commercially practicable or cannot be timely
made, Dimplex may, in lieu of repair or
replacement, choose to refund the purchase price
for such product or part.
§
§
Limited warranty service will be performed solely
by dealers or service agents of Dimplex authorized
to provide limited warranty services.
For products other than surrounds (mantels)
and trims, this 2 year limited warranty entitles the
purchaser to on-site or in-home warranty services.
Accordingly, Dimplex will be responsible for all
labour and transportation associated with repairing
or replacing the product or part except as follows:
(i) charges which may be levied for travel costs
incurred to travel to the purchaser’s site where the
product is located if the purchaser’s site is beyond
30 miles (48 km) from the closest service depot of
Dimplex’s dealer or service agent; and (ii) the
purchaser is solely responsible for providing clear
access to all serviceable parts of the product.
§
For surrounds (mantels) and trims, this 1 year
limited warranty does not entitle the purchaser to
on-site or in-house warranty services. The
purchaser is responsible for removal and
transportation of the surrounds (mantels) and trims
(and any repaired or replacement product or part)
to and from the authorized dealer’s or service
agent’s place of business. On-site or in-home
services for surrounds (mantels) and trims may be
performed at the purchaser’s specific request and
expense at Dimplex’s then-current rates for such
services. Dimplex will not be responsible for, and
this limited warranty shall not include, any
expense incurred for installation or removal of the
surrounds (mantels) or trims or any part thereof (or
any replacement product or part) including, without
15
limitation, all shipping costs and transportation
costs to and from the authorized dealer’s or service
agent’s place of business and all labour costs.
Such costs shall be the purchaser’s responsibility.
What Dimplex and its dealers and service agents are also
not responsible for:
IN NO EVENT WILL DIMPLEX, OR ITS DIRECTORS,
OFFICERS, OR AGENTS, BE LIABLE TO THE
PURCHASER ORANY THIRD PARTY, WHETHER IN
CONTRACT, IN TORT, OR ON ANY OTHER BASIS, FOR
ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY,
CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR
DAMAGE ARISING OUT OF OR IN CONNECTION WITH
THE SALE, MAINTENANCE, USE, OR INABILITY TO USE
THE PRODUCT, EVEN IF DIMPLEX OR ITS DIRECTORS,
OFFICERS, OR AGENTS HAVE BEEN ADVISED OF THE
POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES,
OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE
FORESEEABLE. IN NO EVENT WILL DIMPLEX, OR ITS
OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR
ANY DIRECT LOSSES, COSTS, OR DAMAGES THAT
EXCEED THE PURCHASE PRICE OF THE PRODUCT.
SOME JURISDICTIONS DO NOTALLOW THE EXCLUSION
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION
MAY NOT APPLY TO THE PURCHASER.
How State and Provincial law apply
This limited warranty gives you specific legal rights,
and you may also have other rights which vary from
jurisdiction to jurisdiction. The provisions of the
United Nations Convention on Contracts for the Sale
of Goods shall not apply to this limited warranty or
the sale of products covered by this limited warranty.
16
1-888-DIMPLEX
1-888-346-7539
1367 Industrial Road
Cambridge, Ontario
Canada, N1R 7G8
Approved for use in the United States and Canada
17
|