EverFocus Security Camera EHD150 User Manual

EHD150  
1/3” B/W Rugged Dome Camera  
User’s Manual  
and  
Operation Instructions  
 
Table of Contents  
Safety Warning …………………………………………1  
Introduction……………………………………………..2  
Specification…………………………………………….3  
Installation Instructions………………………….… .… 4  
Dip Switch Functions…………………………….… .… 8  
 
Safety Warning  
1. Do not install the camera near electric or magnetic fields.  
Installed the camera away from TV, radio transmitter, magnet,  
electric motor, transformer, audio speakers because the  
magnetic fields generate from above devices will distort the  
video image.  
2. Do not install the camera in the high temperature environment.  
Installed the camera away from stoves, or other heat  
generating devices as the high temperature could cause  
deformation, discoloration or other damages of the camera.  
Install the camera at where the temperature range will stay  
between -46to 50(-50℉ to122℉ ).  
3. Never face the camera toward the sun.  
Never aim the camera at the sun or other extremely bright objects  
whether it is in use or not.  
4. Cleaning  
Do not touch the surface of CCD sensor by hand directly. Use  
a soft cloth to remove the dirt from the camera body. Use lens  
tissue or a cotton tipped applicator and ethanol to clean the  
CCD sensor and the camera lens. When the camera is not in  
use, put the cover cap on the lens mount.  
5. Heater  
Heater elements could be very hot!! Heaters are located inside  
the camera housing and will active automatically while the  
environment temperature is below 10. Do not touch the  
heater element while it’s active.  
1
 
Introduction  
The most technically advanced EHD150 is the newest vandal-resistant B/W  
Rugged Dome Camera from EverFocus Electronics. The B/W Rugged Dome  
Camera can withstand a blow from a 10-pound sledgehammer and has a  
built-in heater that allows for operation in low temperatures. It is perfect for all  
high-profile crime-prone applications such as building entrances, retail stores,  
and shopping malls. The extremely EHD150 is unquestionably one of the  
world's toughest cameras and is your best choice for vandal resistance.  
Main Features :  
??Designed with advanced digital signal processing circuitry for high image  
quality.  
??The high sensitivity of 0.06 lux/F=1.6 is achieved by high –resolution  
1/3” interline transfer CCD.  
??DC12V or AC24V switches automatically power supply; Line Lock for  
AC24V.  
??S/N Ratio reaches 48 dB or more.  
??Both board lens and vari-focal lens (3.5~8mm or 9~22mm) are available.  
??Compact size: 130mm x 130 mm x 98.9mm  
??Polycarbonate base withstand the impact of a 10 pounds sledgehammer,  
smoke color or clear as option.  
??Unique security screw locked  
??Operating temperature –46 ~ +50 deg Celsius.  
??Heater triggered when temperature less than 10 deg Celsius.  
2
 
Specification  
Pickup device:  
1/3” interline transfer CCD  
NTSC :768(H) × 494(V)  
PAL: 752(H)×582(V)  
560 TV lines  
Picture element:  
Horizontal resolution:  
Sensitivity:  
0.06 lux / F=1.6  
S/N ratio:  
>48dB(AGC off)  
Weatherproof ratings:  
Electronic shutter:  
IRIS Control:  
IP66  
1/60(1/50)~1/100,000(Board lens only)  
Auto (vari-focal lens only)  
on/off switch  
Auto gain control:  
Back light comp:  
Line Lock:  
on/off switch  
on/off switch for 24VAC  
0.45  
Gamma correction:  
Video output:  
1.0Vp-p,75ohm  
Power source:  
12VDC+/-10%, 24VAC+/-10%  
5W Max.  
Power Consumption:  
(15W when heater active; thermostatically controlled)  
Internal Sync. /Line lock (Only AC24V)  
130mm x 130mm x 98.9mm  
Board lens f=3.6, F=2.0  
Vari-focal F=3.5~8mm, F=1.6  
Sync.mode:  
Dimension:  
Lens:  
Heater auto activated temperature: 10, Heater optional  
Operating temperature:  
Weight:  
-46to +50℃  
1.7kg  
3
 
Installation Instructions  
1. Loosen the 4 fix screws on the housing cover by using the attached wrench  
(Figure 1). Carefully uncap the housing cover as the direction shown below  
(Figure 2), please pay attention not to damage the lens. To remove the  
housing cover, push the hinges to the bottom of the bracket, the hinges can  
be easily removed from the bracket.  
Figure 1  
Figure 2  
2. Remove the camera.  
Vari-Focal Lens  
Heater  
Board Lens  
Locking Screws  
Figure 3  
To remove the camera, first unplug the wire connection on the back of the  
camera. Then loosen the 2 locking screws on the camera base, push the  
camera base to the right (toward heater direction, as shown in Figure 3),  
remove the camera from the mounting base. Reinstall the camera and the  
cable while the base mounting is completed.  
4
 
3. Mounting the base.  
Side conduit entry  
Conduit plug setscrew  
Mounting Setscrew  
Back conduit entry  
Mounting Setscrew  
Mounting Setscrew  
Mounting Setscrew  
Figure 4  
Attach the base to the wall or ceiling, fix the base by the 4 setscrews  
attached in the accessory pack. The dome is weighted 1.7kg, please make  
sure if the mounting is strengthened enough to support it, if not,  
please reinforce the mounting according to the environment.  
Note: The diameter of the screw hole isψ4.7mm.  
Back conduit entry (PF1/2)  
The camera comes with a conduit plug  
pre-installed in the PF 1/2 conduit entry  
on the side. The screw can be removed  
and installed in the back conduit entry.  
Loosen the conduit plug setscrew (as  
Conduit plug  
shown in Figure 5) before removing the  
Side conduit entry (PF1/2)  
conduit plug.  
Figure 5  
Caution: To prevent moisture leaking into the housing, apply an  
appropriate gasket or sealant around the conduit connection.  
5
 
4. Wire Connection  
Termination Board  
Micro Switch for Alarm trigger  
Power In  
DC12V (+) or AC24V  
GND  
Video  
Alarm COM  
Alarm NO  
Alarm NC  
Power In  
DC12V (-) or AC24V  
V. Phase Adjustment VR  
Figure 6  
Connect the power supply cable (AC24V/DC12V), video output and alarm  
output to the proper connectors shown as Figure 6.  
The V. Phase adjustment screw is located on the termination board.  
The vertical phase may require adjustment to synchronize the vertical  
phase of the camera with other camera in the system when it is to be used  
in the line-lock sync mode. Make the adjustment when the vertical phase  
of the camera does not match with other cameras.  
6
 
5. View Angel Adjustment  
The camera can be rotated 360°horizontally, and the vertical view angle  
is 140°(as shown in Figure 7). Adjust the proper camera view angel as  
needed. If a vari-focal lens is used, you may adjust the focus and zoom  
of the lens to bring the object in focus. Be sure to loosen the locking  
screws on the lens before you do the adjustments.  
.
140°  
Lens fixing Screws  
360°  
Figure 7  
7
 
LL (Line-Lock) Off/On  
To select the sync mode between Internal Sync.(LL off) and Line-Lock  
(LL on).  
Set the line-lock off, the camera will synchronize to the internal time base.  
Set the line-lock on, the camera’ s vertical synchronization can be driven by  
the AC signal in the power lines.  
Note: Line-  
BLC (Back Light Compensation) On/Normal  
When BLC is turned on, the AGC, ES and IRIS operating point is  
determined by averaging over the center area instead of entire field-of-view,  
so that a dimly-lit foreground object at center area can be clearly  
distinguished from brightly-lit backgrounds.  
BLC should not be used unless it is needed to compensate for back-lit.  
The default setting is Normal.  
FL (Flickerless Function) On/Normal  
When picture flicker fiercely, turn FL on, then the camera will stabilize the  
speed of electronic shutter at 1/100(NTSC) or 1/120(PAL) automatically,  
and reduce the flicker immediately.  
The default setting is Normal.  
ES (Electronic Shutter) Off/On  
ES ON: The camera continuously adjusts the shutter speed from 1/60  
(NTSC), 1/50 (PAL) second to 1/100,000 second according to the  
luminance conditions of the scene.  
ES OFF: The shutter speed is fixed at 1/60 (NTSC), 1/50 (PAL) second.  
Set ES OFF, when auto iris lens is used or flicker is observed under a very  
bright fluorescent lamp. Otherwise, turn ES on for optimum performance.  
The default setting is ON.  
9
 
IRIS Level Adjustment  
Brightness Level can be adjusted from the IRIS level VR while using the  
direct drive lens.  
? Turn counterclockwise to L to get darker picture.  
? Turn clockwise to H to get brighter picture.  
IRIS ALC Adjustment  
To select light metering method –  
? Turn the IRIS ALC Adjustment VR counterclockwise for Average  
Metering.  
? Turn the IRIS ALC Adjustment VR clockwise for Peak Metering.  
10  
 
EverFocus Electronics Corp.  
Head Office:  
12F, No.79 Sec. 1 Shin-Tai Wu Road,  
Hsi-Chi, Taipei, Taiwan  
TEL: 886-2-26982334  
FAX: 886-2-26982380  
USA Office:  
Hong Kong Office:  
2445 Huntington Drive,  
San Marino, CA, 91108  
U.S.A.  
Room 0, 10/F., Block 3, Camelpaint Building,  
60, Hoi Yuen Road, Kwun Tong,  
Kowloon, Hong Kong  
TEL: 1-626-844-8888  
FAX: 1-626-844-8838  
Toll free: 1-888-383-6287 or  
1-888-EV-FOCUS  
TEL: 852-2758-9871  
FAX: 852-2758-9056  
Japan Office:  
WBG Marive East 18F, 1809  
2-6 Nakase, Mihama-ku, Chiba city  
261-7113, Japan  
European Office:  
Albert-Einstein-Strasse 1  
D-46446 Emmerich,  
Germany  
Tel: 81-43-212-8188  
Fax: 81-43-297-0081  
TEL: 49-2822-9394-0  
FAX: 49-2822-939495  
P/N: MD15G00110  
 

Contec Universal Remote RT U27A iPG User Manual
Cub Cadet Lawn Mower 19HP Enforcer 44 21HP Enforcer 48 23HP Enforcer 54 User Manual
Cub Cadet Tiller 394 User Manual
Cuisinart Juicer CJE 1000 User Manual
Delta Electronics Power Supply Series H48SN User Manual
DigiTech Guitar RV 7 User Manual
Dynex Power Supply DX PS350W User Manual
Five Star Ranges Range PN331 7BW User Manual
Fortinet Network Hardware 5103b User Manual
GE Toaster 106686 User Manual