1/3” B/W Digital CCD Camera
User’s Manual
and
Operation Instructions
Table of Contents
Safety Warning …………………………………………1
Introduction……………………………………………..2
Specification…………………………………………….3
Major Parts and Their Functions………………….…..4
Installation Instructions………………………….….…8
Safety Warning
1. Handle the camera with care.
Be careful when handling the camera, do not drop it or subject
it to strong shock or vibration to prevent any damages to it. Do
not disassemble it or place it on an unstable base.
2. Do not install the camera near electric or magnetic fields.
Installed the camera away from TV, radio transmitter, magnet,
electric motor, transformer, audio speakers because the
magnetic fields generate from above devices will distort the
video image.
3. Do not install the camera in the high temperature environment.
Installed the camera away from stoves, or other heat
generating devices as the high temperature could cause
deformation, discoloration or other damages of the camera.
Install the camera at where the temperature range will stay
between 0℃ to 50℃ (32℉ to 122℉).
4. Never face the camera toward the sun.
Never aim the camera at the sun or other extremely bright objects
whether it is in use or not.
5. Cleaning
Do not touch the surface of CCD sensor by hand directly. Use
a soft cloth to remove the dirt from the camera body. Use lens
tissue or a cotton tipped applicator and ethanol to clean the
CCD sensor and the camera lens. When the camera is not in
use, put the cover cap on the lens mount.
1
Introduction
The new EQ120 series is a solid-state B/W video camera specially
designed for high quality surveillance applications. It incorporates
break through DSP technology that provides most reliable and
accurate B/W picture in security industry. The camera is
convenient to use with C-mount or CS-mount lenses and has an easy
back-focus adjustment help to achieve installation efficiency.
Main Features :
¾ 1/3” B/W CCD pick up device for more than 420 TV lines of horizontal
resolution
¾ Sophisticated DSP (Digital Signal Processing) circuitry design that delivers
excellent picture quality and performance.
¾ Wide range automatic electronic shutter: 1/50(1/60)~1/100,000 sec
¾ Auto line lock with external phase adjustment
¾ Used with either C-mount or CS-mount lenses and easy back-focus
Adjustment.
¾ System available in EIA or CCIR.
2
Specification
Pickup Device
1/3" SONY B/W CCD
510 x 492 (EIA)
500 x 580 (CCIR)
420 TV lines
Picture Elements
Horizontal Resolution
Sensitivity
0.01 lux/F=1.2
Over 48 dB (AGC off)
1/50(1/60) ~ 1/100,000 sec
Video / Direct Drive switch
On/Off
S/N Ratio
Electronic Shutter
Auto Iris
Flickerless
Back Light Comp.
Electronic Shutter
Auto Gain Control
Line Lock
On/Off
On/Off
On/Off
On/Off
Audio
Optional
Gamma Correction
Video Output
Power Source
Power Consumption
0.45
BNC 1.0Vp-p,75 ohm
2 types: 12VDC/24VAC, 90~260VAC
5W max
50mm(H) x 57mm (W) x 140.2mm(D);
1.97" (H) x 2.24"(W) x 5.52" (D)
Dimensions
Operating Temparature
Certifications
0°C~50°C ; 32°F~122°F (20%~80% Humidity)
FCC/CE
3
Major Parts Names and Their Functions
1
3
2
Front
Side
6
4
5
8
7
Side
Top
9
9
10
11
Rear (EQ120)
Rear(EQ120A)
4
1. Focal Length Adjustment Ring
Use this ring to adjust the appropriate focal length according to the type of
lens. Rotate the ring clockwise for the CS-mount lens, rotate it
counterclockwise for the C-mount lens. The factory setting is C-mount.
2. Lens Mount
To mount an appropriate C-mount or CS-mount lens.
3. Locking Screw
Use the locking screw to fix the focal length.
4. Lens Connector (4 pin socket)
To connect to the lens plug of the auto IRIS lens.
5. Control Switches
There are 6 control switches located on the sideboard, which are for the
setting of the special features. The switches in orders are for Flickerless,
Back Light Compensation, Electronic Shutter, Automatic Gain Control,
Line-Lock and Auto Iris Lens type.
FL(Flickerless) On/Normal
When picture flicker fiercely, turn FL on, then the camera will stabilize the
speed of electronic shutter at 1/100(EIA) or 1/120(CCIR) automatically, and
reduce the flicker immediately. The default setting is Normal.
BLC (Back Light Compensation) On/Normal
When BLC is turned on, the AGC, ES and IRIS operating point is
determined by averaging over the center area instead of entire field-of-view,
so that a dimly-lit foreground object at center area can be clearly
distinguished from brightly-lit backgrounds.
BLC should not be used unless it is needed to compensate for back-lit. The
default setting is Normal.
5
ES (Electronic Shutter) Off/On
ES ON: The camera continuously adjusts the shutter speed from 1/60 (EIA),
1/50(CCIR) second to 1/100,000 second according to the
luminance conditions of the scene.
ES OFF: The shutter speed is fixed at 1/60 (EIA), 1/50 (CCIR) second.
Set ES OFF, when auto iris lens is used or flicker is observed under a very
bright fluorescent lamp. Otherwise, turn ES on for optimum performance.
The default setting is ON.
AGC (Automatic Gain Control) Off/On
AGC ON: The sensitivity increases automatically when light is low.
AGC OFF: A-low-noise picture is obtained under a low light condition.
The default setting is ON.
LL (Line-Lock) Off/On
To select the sync mode between Internal Sync.(LL off) and Line-Lock
(LL on).
Set the line-lock off, the camera will synchronize to the internal time base.
Set the line-lock on, the camera’s vertical synchronization can be driven by
the AC signal in the power lines.
Note: Line-Lock sync mode operation is possible only when used with an
AC power source; it’s not possible with a DC power source.
6
VD/DD (Auto Iris lens Type)
For video drive auto iris lens, please set switch to VD. For direct drive iris
lens, set switch to DD. The default setting is DD. Wire the cable of lens to
lens connector according to the following table.
Pin1 Pin2
Video Drive +12V GND VD-IRIS GND
Direct Drive Cnt- Cnt+ Drv+ Drv-
6. IRIS Level Control
Pin3
Pin4
Lens Connector
1
2
3
4
Brightness Level can be adjusted from the IRIS level VR while using the
direct drive lens.
Turn counterclockwise to L to get darker picture.
Turn clockwise to H to get brighter picture.
7. V-Phase Adjustment
The vertical phase may require adjustment to synchronize the vertical phase
of the camera with other camera in the system when it is to be used in the
line-lock sync mode. Make the adjustment when the vertical phase of the
camera does not match with other cameras.
8. Mounting Base and Fixing Screws
To use when the mounting bracket is required while mounting the camera.
The mounting base can be attached to either the top or the bottom of the
camera, fix the mounting base onto the camera by using the 4 supplied
fixing screws.
9. Video Output Connector
BNC VBS 1.0 Vp-p, 75ohm
10. Power Cable (EQ120)
11. 12VDC/24VAC Screw Terminals (EQ120A)
7
Installation Instructions
1. Remove the cover cap from the top of the lens mount.
2. To attach a C-mount/CS-mount lens, turn the focal length adjustment
ring to the appropriate position.
Note: If a C-mount lens is used, please make sure the focal length
adjustment ring is set at C position before fixing the lens.
3. Screw the lens firmly onto the lens mount. Insert the lens plug in the
lens connector if the auto iris lens is used.
4. Tighten the locking screw.
5. Connect the video output of the camera to a color monitor or other video
device through a 75 ohm type coaxial cable with BNC female connector.
6. Plug the power cord to the outlet.
7. Once the image appears on the monitor, adjust the focus and diaphragm
of the lens to obtain the best picture.
8. If the subject is not in focus when adjusting focus of lens, do focal
length adjustment as following:
i. Loosen the locking screw of the focal length adjustment ring.
ii. Take picture of subject at a distance more than 20m away from the
camera.
iii. Rotate the focal length adjustment ring to bring the subject in focus.
iv. Tighten the locking screw while the adjustment is completed.
8
EverFocus Electronics Corp.
Head Office:
Europe Office:
12F, No.79 Sec. 1 Shin-Tai Wu Road,
Hsi-Chih, Taipei, Taiwan
TEL: +886-2-26982334
FAX: +886-2-26982380
Albert-Einstein-Strasse 1
D-46446 Emmerich, Germany
TEL: 49-2822-9394-0
China Office:
Room 609, Technology Trade Building,
Shangdi Information Industry Base, Haidian
District, Beijing,China 10085
TEL: +86-10-62973336/37/38/39
FAX: +86-10-62971423
USA L.A. Office:
1801 Highland Ave. Unit A
Duarte, CA 91010, U.S.A.
TEL: +1-626-844-8888
FAX: +1-626-844-8838
Japan Office:
USA N.Y. Office:
1809 WBG MARIBU East 18F,
2-6 Nakase.Mihama-ku.
Chiba city 261-7118, Japan
TEL: +81-43-212-8188
415 Oser Avenue Unit S
Hauppauge, NY 11788
TEL: 631-436-5070
FAX: 631-436-5027
Your EverFocus product is designed and
manufactured with high quality materials and
components which can be recycled and
reused.
Ihr EverFocus Produkt wurde entwickelt und
hergestellt mit qualitativ hochwertigen
Materialien und Komponenten, die recycelt
und wieder verwendet werden können.
Dieses Symbol bedeutet, dass elektrische und
elektronische Geräte am Ende ihrer
Nutzungsdauer vom Hausmüll getrennt
entsorgt werden sollen.
This symbol means that electrical and
electronic equipment, at their end-of-life,
should be disposed of separately from your
household waste.
Please, dispose of this equipment at your
local community waste collection/recycling
centre.
Bitte entsorgen Sie dieses Gerät bei Ihrer
örtlichen kommunalen Sammelstelle oder im
Recycling Centre.
Helfen Sie uns bitte, die Umwelt zu erhalten, in
der wir leben!
In the European Union there are separate
collection systems for used electrical and
electronic product.
Please, help us to conserve the environment
we live in!
P/N: MQ12G0020A VerB
|