Specifications — RG6 Cable  
UL NEC/  
C(UL) CEC  
UL AWM  
Temp.  
Standard  
Lengths Weights  
Shipping Conductor  
Nominal  
Core OD  
Shielding  
Materials  
(% coverage)  
Nom. DCR  
Nominal  
OD  
Nominal  
Capacitance  
Nominal  
Attenuation  
Description  
Nom.  
Vel.  
of  
No.  
of  
Cond.  
Nom.  
Imp.  
(ohms)  
(stranding)  
Diameter  
Nom. DCR  
Part No. (length)  
Model  
dB/  
dB/  
MHz  
Prop.  
Ft.  
m
Lbs. kg  
Inch mm  
Inch mm  
pF/ft pF/m  
100 ft 100 m  
(1 or 5) 18 AWG Coax • Aluminum Foil (100%) + Tinned Copper Braid Shield  
Nonplenum Cable • Gas-injected Foamed Polyethylene Insulation • Gray PVC Outer Jacket  
1
5
10  
20  
50  
-0.3  
-0.5  
-0.7  
-1.0  
-1.5  
-1.6  
-1.9  
-2.1  
-2.6  
-2.8  
-3.0  
-3.8  
-5.0  
-5.9  
-10.7  
-1.0  
-1.8  
-2.3  
-3.3  
-5.0  
-5.2  
-6.2  
-6.9  
-8.5  
-9.2  
-9.8  
-12.5  
-16.4  
-19.4  
-35.1  
18 AWG  
(solid)  
0.040"  
Bonded Alum.  
Foil and  
500 152.4 27 12.2  
1000 304.8 58 26.3  
0.180 4.57  
NEC CM  
UL 1581  
CSA FT-4  
1
coax  
Overall:  
75  
83%  
16.2  
53.1  
22-098-02 (500')  
22-098-03 (1000')  
0.264 6.70  
gray  
Tinned Cu  
Braid (95%)  
RG6-1  
1.02 mm,  
75 °C  
Solid Cu  
2.4 ohms/  
1k ft,  
7.9 ohms/  
1 km  
71  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
6.6 ohms/  
1k ft  
22 ohms/  
1 km  
Min. bend radius: 2.5"  
Sweep tested 5 MHz to 1 GHz.  
Plenum Cable • Gas-injected Foamed FEP Insulation • Blue Fire-resistant PVC Outer Jacket  
1
5
10  
20  
50  
-0.2  
-0.5  
-0.8  
-1.2  
-1.5  
-1.8  
-2.1  
-2.4  
-2.5  
-2.7  
-3.1  
-4.8  
-7.3  
-7.8  
-13.7  
-0.8  
-1.5  
-2.5  
-2.9  
-3.8  
-5.8  
-6.9  
-7.9  
-8.2  
18 AWG  
(solid)  
0.040"  
500 152.4 23 10.4  
1000 304.8 46 20.9  
0.170 4.32  
Overall:  
75  
83%  
16.2  
53.1  
NEC CMP  
UL 910  
1
coax  
Alum. Foil and  
22-164-02 (500')  
22-164-03 (1000')  
Tinned Cu  
Braid (95%)  
0.234  
5.9  
reflex blue  
75 °C  
RG6-1P  
1.02 mm,  
2.4 ohms/  
1k ft,  
7.9 ohms/  
1 km  
Solid Cu  
71  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
6.4 ohms/  
1k ft  
21 ohms/  
1 km  
-8.9  
Min. bend radius: 4.5"  
-10.2  
-15.7  
-23.9  
-25.6  
-44.9  
Sweep tested 5 MHz to 1 GHz.  
Nonplenum Cable • Gas-injected Foamed Polyethylene Insulation • PVC Inner Jackets • Gray PVC Outer Jacket  
Same as  
above  
Same as  
above  
Single:  
0.253 6.43  
red, green,  
1
5
10  
20  
50  
-0.3  
-0.5  
-0.8  
-1.0  
-1.5  
-1.8  
-2.1  
-2.4  
-2.7  
-2.9  
-3.4  
-4.6  
-6.5  
-7.5  
-16.9  
-0.8  
-1.8  
-2.5  
-3.3  
-5.0  
-5.8  
-6.8  
-7.8  
-9.0  
NEC CM  
UL 1581  
CSA FT-4  
5
coax  
22-100-02 (500')  
RG6-5  
75  
83%  
16.2  
53.1  
500 152.4 175 79.4  
0.180 4.57  
blue, black, yellow  
75 °C  
71  
Overall:  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
0.792 20.12  
gray  
-9.5  
-11.2  
-15.0  
-21.2  
-24.6  
-55.4  
Sweep tested 5 MHz to 1 GHz.  
Min. bend radius: 9.0"  
24 November, 2008  
 

Code Alarm Automobile Electronics CA 5051 User Manual
Coleman Camping Equipment 5155 User Manual
Craftsman Lawn Mower 917377582 User Manual
Crosley Refrigerator 241559900 User Manual
Cypress Computer Hardware CY8CNP101 User Manual
Dacor Oven ROV130 User Manual
Delta Electronics Power Supply DNS SIP Series User Manual
Edelbrock Automobile Parts 15017 User Manual
Electro Voice Portable Speaker SL 15 2H User Manual
GBC Paper Shredder 1130S User Manual