S B 1 5 0 z P S p e c i f i c a t i o n s  
group · I  
15 INCH SUBWOOFER  
See TABULAR DATA notes for details, half space = floor-mounted  
CONFIGURATION  
Subsystem  
Transducer  
Loading  
SUB 1x 15 in cone  
Vented  
Operating Mode  
Amplifier Channels  
External Signal Processing  
Single-amp LF  
DSP w/1-way filter  
PERFORMANCE 1  
Operating Range  
34 Hz to 145 Hz  
Nominal Beamwidth  
Horz 360°  
Vert 360°  
Axial Sensitivity (SPL)  
LF (whole space) 94 dB  
(half space) 100 dB  
Input Impedance (ohms)  
Nominal  
34 Hz to 145 Hz  
34 Hz to 145 Hz  
Minimum  
LF  
8
6.9 @ 40 Hz  
High Pass Filter  
High Pass =>30 Hz, 12 dB/octave Butterworth  
Accelerated Life Test 2  
LF 65 V  
700 W  
525 W @ 8 ohm  
Transducer (AES)  
DESCRIPTION  
Calculated Axial Output Limit (SPL)  
Average  
Peak  
127 dB  
133 dB  
The SB products are EAW's premium subwoofers designed for  
the most demanding professional applications. Abroad range of  
capabilities and sizes provide the designer with selections that  
can be specifically matched to their application. Top quality  
drivers, engineered by EAW, provide the highest output and best  
sonic performance possible for a given form factor. All SB  
models are direct radiating, with optimally tuned, vented  
enclosures. SB subwoofers are the choice where the best sonic  
performance, highest reliability, and most robust physical  
construction are required.  
LF (whole space) 121 dB  
(half space) 127 dB  
ORDERING DATA  
Description  
Part Number  
0008960  
SB150zP 15 inch Subwoofer Black  
SB150zP 15 inch Subwoofer White  
SB150zP 15 inch Subwoofer Black WP  
Optional Accessories  
0012192  
0009038  
3/8-16 Forged Shoulder Eyebolt  
104001  
The SB150zP is a high output, compact subwoofer system. This  
versatile, all-purpose subwoofer is designed for permanent  
installation where the solid-sounding output of a 15 inch driver is  
desired. The SB150zP works well with most full-range  
loudspeakers in a variety of applications including: small houses  
of worship, A/V systems, hotel ballrooms, meeting rooms,  
classrooms, exhibit areas, f/x reinforcement, cruise ships,  
cinemas, TV studios, restaurants, and small retail spaces.  
The SB150zP is designed to be used with today's sophisticated  
digital signal processing to optimize the LF response. EAW's MX  
Series processors are recommended for the required crossover  
and equalization.  
Six Year Warranty.  
1 To achieve specified performance, the listed external signal processing with EAW-provided settings is required.  
2 For recommendations to select power amplifier size refer to : “HOW MUCHAMPLIFIER POWER DO I NEED?” on the EAW web site.  
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com  
EAW products are continually improved. All specifications are therefore subject to change without notice.  
Part Number: RD0308 (A) SB150zP April 2005  
 
S B 1 5 0 z P S p e c i f i c a t i o n s  
group · I  
PERFORMANCE DATA  
See NOTES GRAPHIC DATA for details  
Frequency Response: Processed  
LF Whole Space = green  
10  
0
-10  
-20  
-30  
-40  
-50  
10  
100  
1000  
20000  
Frequency (Hz)  
Frequency Response: Digital Signal Processor  
LF = green  
Frequency Response: Unprocessed  
LF Whole Space = green  
120  
110  
100  
90  
20  
10  
0
-10  
-20  
-30  
80  
70  
60  
-40  
10  
10  
100  
1000  
20000  
100  
1000  
20000  
Frequency (Hz)  
Frequency (Hz)  
Impedance Magnitude  
LF = green  
100  
10  
1
10  
100  
1000  
20000  
Frequency (Hz)  
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com  
EAW products are continually improved. All specifications are therefore subject to change without notice.  
Part Number: RD0308 (A) SB150zP April 2005  
 
S B 1 5 0 z P S p e c i f i c a t i o n s  
group · I  
INPUT PANEL  
SIGNAL DIAGRAM  
1-Way, Single-Amp (LF)  
SB150zP  
S/N  
DSP  
EQ  
WHITINSVILLE, MA USA  
AMP  
LF  
HPF  
LPF  
LOOP THRU  
LEGEND  
DSP:  
HPF:  
LPF:  
User-supplied Digital Signal Processor.  
High Pass Filter for crossover or specified High Pass Filter.  
Low Pass Filter for crossover.  
LF/MF/HF: Low Frequency / Mid Frequency / High Frequency.  
AMP:  
XVR:  
User-supplied Power Amplifier.  
Passive LPFs, HPFs, and EQ integral to the loudspeaker.  
-- + -- +  
NOTES  
TABULAR DATA  
1. Measurement/Data Processing Systems: Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012.  
2. Microphone Systems: Earthworks M30; Brüel & Kjær 4133  
3. Measurements: Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep.  
4. Measurement System Qualification (includes all uncertainties): SPL: accuracy +/-0.2 dB @ 1 kHz, precision +/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: accuracy +/-1 %,  
precision +/-0.1 Hz, resolution the larger of 1.5 Hz or 1/48 octave; Time: accuracy +/-10.4 µs, precision +/-0.5 µs, resolution 10.4 µs;Angular: accuracy +/-1°, precision +/-0.5°, resolution 0.5°.  
5. Environment: Measurements time-widowed and processed to eliminate room effects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted.  
6. Measurement Distance: 7.46 m.Acoustic responses represent complex summation of the subsystems at 20 m. SPLis referenced to other distances using the Inverse Square Law.  
7. Volts: Measured rms value of the test signal.  
8. Watts: Per audio industry practice, “loudspeaker watts” are calculated as voltage squared divided by rated nominal impedance. Thus, these are not True Watt units of energy as defined by  
International Standard.  
9. SPL: (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL= 20 microPascals.  
10. Subsystem: This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency.  
11. Operating Mode: User selectable configurations. Between system elements, a comma (,) = separate amplifier channels; a slash (/) = single amplifier channel. DSP= Digital Signal Processor.  
IMPORTANT: To achieve the specified performance, the listed external signal processing must be used with EAW-provided settings.  
12. Operating Range: Range where the processed Frequency Response stays within -10 dB SPLof the power averaged SPLwithin this range; measured on the geometric axis. Narrow band  
dips are excepted.  
13. Nominal Beamwidth: Design angle for the -6 dB SPLpoints, referenced to 0 dB SPLas the highest level.  
14. Axial Sensitivity: Power averaged SPLover the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on the  
geometric axis, referenced to 1 m.  
15. Nominal Impedance: Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range.  
16. High Pass Filter: This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range.  
17. Accelerated Life Test: System: Maximum test input voltage applied with an EIA-426B defined spectrum; measured with specified signal processing; Transducer:AES2-1984 R 1997.  
18. CalculatedAxial Output Limit: Highest average and peak SPLs possible during theAccelerated Life Test. The Peak SPLrepresents the 2:1 (6 dB) crest factor of the Life Test signal.  
GRAPHIC DATA  
1. Resolution: To remove insignificant fine details, 1/12 octave cepstral smoothing was applied to acoustic frequency responses and 1/3 octave cepstral smoothing was applied to the  
beamwidth and impedance data. Other graphs are plotted using raw data.  
2. Frequency Responses: Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance),  
2.83 V (8 ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m.  
3. Processor Response: The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference.  
4. Impedance: Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not  
be used to calculate True Watts (see 8 above).  
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com  
EAW products are continually improved. All specifications are therefore subject to change without notice.  
Part Number: RD0308 (A) SB150zP April 2005  
 

Edimax Technology Security Camera MD 111E User Manual
Electro Voice Portable Speaker PI94 User Manual
Essick Air Humidifier E27 000 User Manual
Field Controls Automobile Parts SWG 4HD User Manual
FMI Indoor Fireplace DVF36NH HA User Manual
Frigidaire Dishwasher FFBD2405KB0 User Manual
FujiFilm Film Camera AF3 007E User Manual
Gateway Server 9715 User Manual
GE Range 164D4290P024 User Manual
GE Universal Remote RM94901 User Manual