SPECIFICATIONS
Remote type, electric refrigerated, water chiller unit. Chilling capacity of
1.3 gallons per hour of 50°F drinking water, based upon 80°F inlet water
and 90°F ambient. (A.R.I. Standard Ratings).
Compact, highly efficient water chiller units are designed for use with
any drinking water faucet. Installs directly under kitchen counter, in
well-ventilated cabinet.
NOLEADDESIGN
THIS WATER CHILLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATERACT OF 1986
AND LEAD CONTAMINATION CONTROLACT OF 1988.
This Water Chiller is manufactured with a waterway system utilizing
stainless steel components and completely lead-free materials. These
waterways have no lead because all lead-containing materials, such as
leaded brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. Ideal for use with filter treated
water, domestic water supply or reverse osmosis systems.
This water chiller is classified by Underwriters Laboratories
Inc. in accordance with NSF/ANSI 61-2002e.
CGCL1 Remote Chiller
GPH of 50°F Drinking Water
Inlet
Water
Temp
(°F)
Full
Load
Amps
Ship
Wt.
Lbs.
Room Temperature °F
Model
Number
Base
Rate
Watts
Rated
70
80
90
100
CONSTRUCTION
Cabinet: Rust-resistant, galvanized steel.
70
80
90
2.1
2.0
1.8
1.6
CGCL1 1.3
1.5
1.1
1.4
1.0
1.3
.9
1.2
.8
155
1.7
35
Drain Plug: This chiller is provided with a plastic drain plug which
incorporates an o-ring seal. This fitting is designed for potable
water applications and should be replaced with a suitable fitting if
chiller is used with more aggressive liquids.
Rated watts shown are based on operational (run) time, in accordance with ARI
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people served
per hour (usage), ambient temperatures, and inlet water temperature.
5 YEAR LIMITED WARRANTY on the refrigeration system of the
unit. Electrical components and water system are warranted for 12
months from date of installation. Warranty pertains to drinking
water applications only. Non-drinking water applications are not
covered under warranty. Sample Certificate available on request.
Multiple-outlet capacities. Service to 1 station only.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
1/18 HP, 115VAC, 60Hz single phase. Sealed in lifetime oil supply.
Note: In keeping with our policy of continuing product improvement,
Everpure reserves the right to change materials, design and
specifications without notice.
Power: Rated 1.7 Amps; 155 watts
This Air Cooled Water Chiller is listed by Underwriters Laboratories
for Drinking Water Coolers and Drinking Water Coolers certified for
Canada, rated in accordance with A.R.I. Standard 1010 and meets
all known federal and state plumbing codes.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is
permanently lubricated.
Cooling Unit: Combination tube-tank type. Evaporator cooling coil of
continuous copper tubing. Tank is stainless steel. Tank volume is 0.7
gallons. All water contact surfaces are stainless steel. Fully insulated.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately
calibrated capillary tube for positively trouble-free operation.
Temperature Control: Enclosed adjustable thermostat is factory
preset. Requires no adjustment other than for altitude requirements.
Manufactured for Everpure, LLC by Elkay Manufacturing Company.
This specification describes a product with design, quality and functional benefits to the user. When
making a comparison of other producers' offerings, be certain these features are not overlooked.
Everpure, LLC
1040 Muirfield Dr.
Hanover Park, IL 60133
1.800.323.7873
Tech. Service 1.800.942.1153
PAGE1
98256C (Rev. A - 4/06)
Model CGCL1
INSTALLATION
1. This unit is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36" (914mm) wide (inside dimension).
Two air openings with a minimum of 40" square (1016mm/square) each, minimum of 75% open area, must be provided in the cabinet. One
opening must be in the overhang of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with a
minimum of 3" clearance between the unit and the rear wall of the cabinet. It can be installed flush against either side wall of the cabinet. The
side louvers which are not against the cabinet must not be blocked by objects located within 4" (102mm) of the louvers. In addition, a minimum of
1 to 2" (25 to 51mm) clearance must be provided between the toe space air opening and front of the unit.
2. Water inlet and outlet are 1/4" (6 mm) O.D. tubes.
3. Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler.
4. Connect cooler to supply line with a shut-off valve and install a 1/4" O.D. (6 mm) tube. Make sure the cold water connecting to the faucet is
filtered. Use an Everpure Commercial Grade Filter System to provide filtered water. Refer to the Everpure Filter system Install and Operation
Manual for installation procedures.
CAUTION: Under certain conditions i.e., fluctuations in line pressure, water temperature, intermittent use, it is recommended to use a mini
expansion tank to allow water expansion. See Everpure part number EV310413, not included in box.
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor
directly to the power supply.
START-UP
1. Open supply line valve.
2. Purge air from all water lines by using water through faucet. A steady stream assures all air is removed.
3. Rotate fan to insure proper clearance and free fan action.
4. Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control:
Factory set at 50°F under normal conditions. For colder water, adjust screw on item no. 10 in clockwise direction.
Ventilation:
Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can
cause no cold water and compressor cycling on the compressor overload protector.
Lubrication:
Motors are lifetime lubricated.
PAGE3
98256C (Rev. A - 4/06)
Model CGCL1
1/4" O.D. Tube Water
Inlet To Cooler
Building Water Inlet
Service Stop
(Not Furnished)
See Everpure No. EV312120
A) AIR VENT
B) CONDENSER SIDE FORWARD
C) CAN BE MOUNTED FLUSH AGAINST EITHER
SIDE OF CABINET
Repair Service Information Toll Free Number 1.800.942.1153
Manufactured for Everpure,LLC by Elkay Manufacturing Company
98256C (Rev. A - 4/06)
PAGE4
|