PERFORMANCE  
DATA SHEET  
WATER TREATMENT PRODUCTS  
1040 Muirfield Drive • Hanover Park, IL 60133 • 630.307.3000 • FAX 630.307.3030  
MH AND MH2 WATER FILTERS  
MH Cartridge Part No. EV9613-01 (1-pack)  
Part No. EV9613-06 (6-pack)  
OPERATING SPECIFICATIONS  
• Pressure requirement: 10-125 psi (0.7-8.6 bar), non-shock  
• Temperature: 35-100° F (2-38° C)  
MH2 Cartridge Part No. EV9613-21 (1-pack)  
Part No. EV9613-26 (6-pack)  
NSF Listed Systems  
QC7I Single - MH  
QC7I Single - MH2  
QC7I Twin - MH  
QC7I Twin - MH2  
QC7I Triple - MH  
QC7I Triple - MH2  
QC7I Quad - MH  
QC7I Quad - MH2  
Max. Flow Rate  
1.67 gpm (6.3 lpm)  
1.67 gpm (6.3 lpm)  
3.3 gpm (12.6 lpm)  
3.3 gpm (12.6 lpm)  
5.0 gpm (18.9 lpm)  
5.0 gpm (18.9 lpm)  
6.6 gpm (25.3 lpm)  
6.6 gpm (25.3 lpm)  
Capacity  
Space Requirements*  
29" H x 512" W x 5" D  
29" H x 512" W x 5" D  
25" H x 11" W x 5" D  
25" H x 11" W x 5" D  
25" H x 15" W x 5" D  
25" H x 15" W x 5" D  
29" H x 24" W x 5" D  
29" H x 24" W x 5" D  
9,000 gal (34,050 L)  
9,000 gal (34,050 L)  
18,000 gal (68,100 L)  
18,000 gal (68,100 L)  
27,000 gal (102,150 L)  
27,000 gal (102,150 L)  
36,000 gal (136,200 L)  
36,000 gal (136,200 L)  
FEATURES  
• Finely polishes treated water to premium quality.  
• Reduces chlorine taste and odor.  
• Reduces dirt, rust, asbestos fibers, and other particulates  
including oxidized iron, manganese, and sulfides.  
• Reduces parasitic protozoan cysts such as Giardia, Entamoeba,  
and Cryptosporidium.  
* Includes 212” clearance under unit for cartridge change  
• Reduces common earthy, moldy, fishy tastes and odors  
• Inhibits limescale build-up in ice machines – As tested by  
Everpure.  
SPECIAL NOTICES  
• Installation instructions, parts and service availability, and  
standard warranty are included with the product when shipped.  
• This drinking water system must be maintained according to  
manufacturer’s instructions, including replacement of filter  
cartridges.  
• Do not use with water that is microbiologically unsafe, or of  
unknown quality without adequate disinfection before or after  
the system. Systems certified for cyst reduction may be used on  
disinfected waters that may contain filterable cysts.  
• The contaminants or other substances removed or reduced by  
this water treatment system are not necessarily in your water.  
• Check for compliance with state and local laws and regulations.  
• Tested under standard laboratory conditions as specified above.  
Actual performance may vary depending on influent water  
conditions.  
• MH2 cartridges are treated with bacteriostat to effectively reduce the  
growth of bacteria on the filter media. Not Performance Tested or  
Certified by NSF.  
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*  
This system has been tested according to NSF/ANSI 42 and 53 for the  
reduction of the substances listed below. The concentration of the  
indicated substances in water entering the system was reduced to  
a concentration less than or equal to the permissible limit for water  
leaving the system, as specified in NSF/ANSI 42 and 53.  
Influent Challenge  
Concentration  
Max. Permissable Product  
Water Concentration  
Reduction  
Minimum  
Average  
Substance  
Requirements Reduction Reduction  
Standard 42—Aesthetic Effects  
Chlorine  
2.0 mg/L ± 10%  
≥ 50%  
≥ 85%  
87.8%  
99.2%  
Particulate,  
Class I  
particles 0.5  
to <1 µm  
• To determine NSF Model Name, combine HEAD NAME +  
at least 10,000  
particles/mL  
Standard 53—Health Effects  
Turbidity  
Asbestos  
Cyst  
11 ± 1 NTU  
0.5 NTU  
95.4%  
99.87%  
99.99%  
97.2%  
99.87%  
99.99%  
System Tested and Certified by NSF International against  
NSF/ANSI Standards 42 and 53 for the reduction of:  
107 to 108 fibers/L > 10  
micrometers in length  
99%  
Standard No. 42 —  
Aesthetic Effects  
Chemical Reduction  
Minimum 50,000/L  
99.95%  
Taste and Odor  
Chlorine  
Mechanical Filtration  
Particulate Class I: 99.2% reduction of particles  
one-half micron and larger in size  
* Tested using flow rate = 1.67 gpm; pressure = 60 psig; pH = 7.5 ± 1;  
temp. = 20° ± 3°C  
† NTU = Nephelometric Turbidity Units  
Standard No. 53 —  
Health Effects  
Mechanical Filtration  
Turbidity  
Cyst  
Asbestos  
GENERAL INSTALLATION/OPERATION/MAINTENANCE  
REQUIREMENTS  
• Install vertically with cartridge hanging down  
• Use minimum length of tubing possible  
• Flush to drain for 5 minutes at full flow  
• Replace cartridges when capacity is reached or when flow  
becomes too slow, but at least annually.  
Buyer  
©2005 Everpure, LLC  
Seller  
Date  
EV7013-18B OC05  
 

EdgeStar Beverage Dispenser TBC50BL User Manual
Exido Scale 246 020 User Manual
Finlandia Electric Heater JM 17 User Manual
Frigidaire Air Conditioner FRS09PYC11 User Manual
Frigidaire Oven GLEB27Z7HB User Manual
Furman Sound Power Supply PS PRO HT User Manual
Fusion Battery Charger L702B User Manual
Gianni Industries Door FDH 100M User Manual
Goodman Mfg Air Conditioner SX14 R 410A User Manual
Goodman Mfg Heat Pump GSZ VSZ 13 SEER User Manual