Faber Blower Remote Blower User Manual

Concept  
Remote Blower  
Instruction Manual  
READ AND SAVE THESE INSTRUCTIONS  
The Installer must leave these instructions with the homeowner. The homeowner must keep these instructions for future reference and for local  
electrical inspectors’ use.  
 
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD  
READ AND SAVE THESE INSTRUCTIONS  
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers  
cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn hood ON when cooking at high  
heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè). Clean ventilating fans frequently. Grease  
should not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the size of the surface element.  
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE  
FOLLOWING: SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT  
BURNS. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN - You  
may be burned. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. Use an extinguisher ONLY if:  
1. You know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and contained in the area where  
it started. 3. The fire department is being called. 4. You can fight the fire with your back to an exit.  
CAUTION: To Reduce The Risk Of Fire And Electric Shock, Install This RangeHood Only With Remote Blower Models Rated Maximum. 4,2 A  
suitable for use with solid stade speed controls.  
WARRANTY & SERVICE  
This rangehood carries a limited warranty against manufacturer’s defects. To obtain warranty service, contact the dealer from whom you  
purchased the rangehood, or the local Faber distributor. If you cannot identify a local Faber distributor, contact Faber USA at (508) 358-5353 for  
the name of a distributor in your area.  
USE AND CARE INFORMATION  
This rangehood system is designed to remove smoke, cooking vapors and odors from the cooktop area. This unit also has several features  
to insure operator safety.  
VENTING REQUIREMENTS  
Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof.  
The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork  
should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall  
or floor opening around the cap. Flexible ductwork is not recommended. If it is used, each foot of flexible ductwork used is equivalent to two feet  
of straight metal ductwork when calculating the ductrun length. Thus, a flexible elbow equals two standard elbows.  
Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely  
necessary. If a joist or stud must be cut, then a supporting frame must be constructed. For best results, remote blowers should transition to 10"  
round duct as soon as possible. If small ducting is used, it should be transitioned to 9 or 10" round as soon as possible.  
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.  
! WARNING  
Venting system MUST terminate outside the home.  
DO NOT terminate the ductwork in an attic or other enclosed space.  
DO NOT use 4" laundry-type wall caps.  
Flexible-type ductwork is not recommended.  
DO NOT obstruct the flow of combustion and ventilation air.  
Failure to follow venting requirements may result in a fire.  
ELECTRICAL REQUIREMENTS  
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp circuit, fused on both sides of the line. A time-delay fuse or circuit  
breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/  
rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER  
WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and  
ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained  
from:  
National Fire Protection Association  
Batterymarch Park  
Quincy, Massachusetts 02269  
EN  
3
 
This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed  
copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector  
must be provided at each end of the power supply cable (at the appliance and at the junction box).  
When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal  
must have a grommet.  
SUITABLE FOR USE WITH SOLID STATE SPEED CONTROLS. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR  
INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions,  
contact the manufacturer.  
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being  
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,  
to the service panel.  
CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.  
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Installation  
Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated  
Construction.  
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent  
backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire  
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local  
code authorities.  
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.  
Ducted fans must always be vented to the outdoors.  
! WARNING  
Electrical ground is required on this rangehood.  
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO NOT use for grounding.  
DO NOT ground to a gas pipe.  
DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could  
result in electrical shock.  
Check with a qualified electrician if you are in doubt as to whether the rangehood is properly grounded.  
Failure to follow electrical requirements may result in a fire.  
4
EN  
 
CHARACTERISTICS  
Components  
Q.ty  
D
C
1
1
Hood Body, complete with: Blower, Filters, Controls  
Built-in hood body case  
2
1
1
1
1
3
Rear remote motor connection panel  
Top air outlet flange with valve  
Top air outlet plug  
4
F
E
12  
5
13  
G
11  
10  
11  
12  
13  
1
4
2
2
Light  
Support arms  
Bush masking plug  
Arm support bush  
10  
5
A
10  
4
Screws 3,5 x 16  
Screws 5 x 70  
2
C
4
D
E
F
4
Wall Plugs ø 10  
Screwsfor wall plugs ø 5  
Wall Plugs ø 5  
2
2
G
4
Grub screws  
3
1
A
Dimensions  
EN  
5
 
Dimensional chart - Hood  
Distance from  
the Hob  
6
EN  
 
Dimensional chart - LIGHT  
EN  
7
 
INSTALLATION  
The hood can be installed in the following ways: top air outlet, bottom air outlet, rear air outlet. Once the desired configuration has been chosen  
(see the diagrams below) it will be necessary to provide an opening in the wall where to house the built-in hood body case. Besides the air  
ducting pipes, basing on the chosen configuration, the hood has to be electrically connected, and an additional connection raceway between  
the hood installation area and the lighting area has to be provided.  
HOOD INSTALLATION SCHEME  
RECESSED HOUSING LOWER BORDER SHALL BE INSTALLED AT THE MINIMUM DISTANCE OF 7-3/32 IN. ABOVE THE COOKING  
SURFACE.  
• Basing on the following scheme prepare the opening H for housing the built-in hood body case. In case of the bottom air outlet  
configuration consider that the holes for electrical connection have to be made up on the left side (position U).  
• Concerning the ductrun consider the figures in the following scheme bearing in mind that the rear hole P serves only for the rear  
air outlet-configuration.  
3-11/32  
10  
7/8  
U
P
H
CALCULATE THE DUCTRUN LENGTH  
The ductwork length should not exceed 35 equivalent feet for 3 1/4" X 10" duct, or 55 equivalent feet for 9" or 10" round duct. Calculate the  
length of the ductwork by adding the equivalent feet listed in FIGURE 1 for each piece of duct in the complete system. An example is given in  
FIGURE 2. For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if  
more than one is used. Do not install two elbows together. Round duct is recommended instead of rectangular duct especially if elbows are  
needed. For internal blower models, rectangular duct should be transitioned to 9" round as soon as possible.  
9 Feet Straight Duct 9.0 feet  
45° Elbow  
90° Elbow  
90° Flat Elbow 12.0 feet  
Wall Cap 0.0 feet  
5.0 feet  
7.0 feet  
2 - 90° Elbows  
Wall Cap  
14.0 feet  
0.0 feet  
Total System  
23.0 feet  
FIGURE 2  
FIGURE 1  
8
EN  
 
LIGHTING UNIT INSTALLATION SCHEME  
LIGHTING UNITLOWER BORDER SHALLBE INSTALLEDATTHE MINIMUM DISTANCE OF 34 9/16 IN.ABOVETHE COOKING SURFACE.  
With the aid of the drilling template provided mark the necessary holes and drill them.  
ø15/16  
TOP OR BOTTOM AIR OUTLET CONFIGURATION  
The hood is manufactured with the air outlet at the top.  
• Fit the flange with non-return valve onto the air outlet position of the  
built-in hood body case.  
• In case of the bottom air outlet configuration turn the built-in hood body  
case 180° before fixing it to the wall.  
EN  
9
 
REAR AIR OUTLET CONFIGURATION  
• Remove the suction panel by unfastening the 8 screws around the frame.  
• Remove the metal grease filters.  
• Remove the metal profile fixed to the flange by unfastening the 5 screws.  
• Fit the air outlet plug into the top air outlet.  
• Remove the rear air outlet plug .  
• Fit the rear air outlet flange in place of the plug  
Built-in hood body case installation  
FIXING INTO THE BRICK WALL  
• With the aid of pliers bend the lateral metal tongues of the built-in case.  
• It is necessary to wall the built-in hood body case inside the hollow in  
the wall paying attention that the external edge of the built-in case adheres  
perfectly to the wall. It is necessary that the built-in case is precisely  
levelled both horizontally and vertically, and that the air outlet flange is  
correctly placed inside the ductrun.  
BEFORE INSTALLING THE HOOD IT WILL BE NECESSARY TO WAIT  
UNTILL THE BUILT-IN HOOD BODY CASE WALLING PROCESS IS  
COMPLETELY TERMINATED.  
FIXING INTO THE WOODEN WALL  
• Insert the built-in hood body case inside the wall paying attention that  
the built-in case is precisely levelled both horizontally and vertically.  
• Fix the built-in case to the wall using the 10 screws A (3,5x16) provided.  
10  
EN  
 
Hood body installation  
• In case of the bottom air outlet configuration the hood body has to be turned  
180°.  
• Remove the top cover of the terminal box by unfastening the two screws  
fixing it to the hood casing.  
• With the aid of pliers brake through a hole inside the terminal box  
providing thus for a passage of the electrical connection for the lighting  
unit.  
• Place the hood body inside the built-in case paying attention  
that the screws of the built-in case fall to the gaps of the  
hood body.  
• Once the screws have reached the gaps it is necessary to  
fasten them in order to definitively fix the hood body inside  
the built-in case.  
• It is necessary to make sure that the hood body air outlet is  
correctly in its’ position inside the air outlet of the built-  
in case.  
EN  
11  
 
Lighting unit installation  
• Provide for passage of the electrical connection wires with the hood  
body.  
• Slide the top cover downwards, unfastening the two side screws and taking  
care not to scratch the tubular support members.  
• Insert the 4 plugs D into the earlier drilled holes.  
• Decide the height of the light; loosen the grub screws on the outer  
columns to allow the light to slide up and down. Take care not to scratch  
the columns when sliding.  
• Fasten the light to the ceiling using 4 screws C.  
• Fix the two support arm connection bushes to the wall..  
green  
ground  
screw  
hood wiring  
• Make electrical connection:  
• Connect the red wire in the Light-unit with the red lead in the hood using  
a twist-on connector; connect the purple wire in the Light-unit with the  
purple lead in the hood using a twist-on connector.  
• Connect the green ground wire to the unused, green ground screw.  
light wiring  
• Replace the top cover, fixing it in place with the two side screws.  
purple wiring  
red wiring  
twist-on  
connectors  
• Screw the support arms into their housings.  
• Hook them to the connection bushes and lock them in position with the  
grub screws provided.  
• Close the bush using the masking plug provided  
12  
EN  
 
Electrical connection  
! WARNING  
ELECTRICAL SHOCK HAZARD  
Disconnect power before making electrical connctions.  
Connect ground wire to green ground screw in terminal box.  
green  
ground  
screw  
• Connect the red wire of the Light cable with the red lead in the hood  
hood wiring  
hood wiring  
using a twist-on connector; connect the purple wire of the Light cable  
with the purple lead in the hood using a twist-on connector.  
• Connect the blue blower wire with the blue lead in the hood using a twist-  
on connector; connect the brown blower wire with the brown lead in the  
hood using a twist-on connector.  
twist-on  
connectors  
blue wiring  
black wiring  
white wiring  
brown wiring  
• Connect the ligth unit to the ground using one of the following two alter-  
native ways:  
a- Connect the domestic green ground wire under the unused green ground  
screw belonging to the light unit wiring box using a listed conduit  
connector.  
b- Connect one end of the green ground wire (max lenght 10 yards using  
14 awg wire) under the unused green ground screw belonging to the  
light unit wiring box and the other end under the unused green ground  
screw belonging to the range hood wiring box.  
exterior  
blower  
wiring  
power  
supply  
conduit  
light wiring  
red wiring  
purple wiring  
• Connect the green ground wire (from exterior blower and from power  
supply cable) under the unused green ground screw.  
• Tighten strain relief screws.  
• Connect the white wire of the power supply conduit with the white lead  
in the hood using a twist-on connector; connect the black wire of the  
power supply conduit with the black lead in the hood using a twist-on  
connector.  
• Place the suction panel so that the connection flat wiring for the hood  
controls passes through the specific opening in the hood body.  
• Fix the suction panel to the hood body fastening the screws removed  
earlier.  
• Open the suction cover using the lever provided.  
• Connect the flat connection wiring coming from the hood controls with  
the connector piece placed close to the terminal box. Only in case of the  
bottom air outlet configuration remove the protection cover from the  
connector piece on the opposite side of the terminal box.  
• Fix the terminal box cover again and fasten the 2 screws removed earlier.  
• Replace the metal grease filters in their housings.  
• Close the suction panel.  
EN  
13  
 
USE  
Control Panel  
S1  
L
T1  
T2  
T3  
T4  
The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.  
LED  
FUNCTIONS  
L
0/1 Light  
Turns lighting on and off.  
T1  
0/1 Motor  
Fixed  
First speed.  
When pressed for about 2 seconds the motor is switched off.  
T2  
T3  
T4  
Speed  
Speed  
Speed  
Fixed  
on  
Second speed.  
Third speed.  
Max. speed  
Fixed  
Flashing  
Intensive speed.  
Suitable for the strongest cooking vapours and odours. The function becomes active when the  
button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically.  
This function can be interrupted by means of pressing any of the buttons.  
S1  
Led  
Fixed  
Indicates that the Metal grease filters saturation alarm has been triggered, and the filters need to  
be washed. The alarm is triggered after 100 working hours. (Reset; check the Maintenance-  
paragraph)  
Flashing  
indicates that the activated charcoal odour filter saturation alarm has been triggered, and the  
filter has to be replaced; the metal grease filters must also be washed. The activated charcoal  
odour filter is triggered after 200 working hours. (Activation and Reset; check the Maintenance-  
paragraph)  
MAINTENANCE  
Greasefilters  
CLEANING METAL GREASE FILTERS  
Alarm signal reset  
• Switch off the lights and extractor motor.  
• Press button T3 for at least 3 seconds, until the leds start to flash.  
Cleaning the filters  
• Open the suction cover using the lever provided.  
• The filters are washable and must be cleaned when the Led S1 lights up  
or at least every 2 months of operation, or more frequently for particularly  
heavy usage.  
• Remove the filters one at a time by pushing them towards the back of the  
group and pulling down at the same time.  
Wash the filters, taking care not to bend them. Allow them to dry before  
refitting.  
• When refitting the filters, make sure that the handle is visible on the  
outside.  
• Close the suction panel.  
14  
EN  
 
Lighting  
LIGHT REPLACEMENT  
20 W halogen light.  
• Extract the lamp from the Support.  
• Replace with another of the same type, making sure that the two pins are  
properly inserted in the lamp holder socket holes.  
ElectricDiagram  
EN  
15  
 
436002499_02 - 041103  
 

Edimax Technology Network Router Wireless VPN Broadband Router User Manual
Edirol Computer Keyboard PC 50 User Manual
Electro Voice Portable Speaker DMS 1152 Series User Manual
Electro Voice Portable Speaker S1522ER User Manual
Fender Guitar G 5 User Manual
Gateway Car Stereo System 8450R User Manual
GE Microwave Oven JE1660 User Manual
GE Monogram Oven 30 Wall Oven User Manual
Goodman Mfg Air Conditioner goodman High Efficiency 2 to 5 Ton Split System Air Conditioner User Manual
G Technology Computer Hardware 0G00273 User Manual