Fluke Thermometer 80K 6 User Manual

LIMITED WARRANTY & LIMITATION OF LIABILITY  
®
Each Fluke product is warranted to be free from defects in material and  
workmanship under normal use and service. The warranty period is one  
year and begins on the date of shipment. Parts, product repairs and  
services are warranted for 90 days. This warranty extends only to the  
original buyer or end-user customer of a Fluke authorized reseller, and  
does not apply to fuses, disposable batteries or to any product which, in  
Fluke’s opinion, has been misused, altered, neglected or damaged by  
accident or abnormal conditions of operation or handling. Fluke warrants  
that software will operate substantially in accordance with its functional  
specifications for 90 days and that it has been properly recorded on non-  
defective media. Fluke does not warrant that software will be error free or  
operate without interruption.  
80K-6  
High Voltage Probe  
Instruction Sheet  
Description  
The 80K-6 is a high voltage probe designed to extend the voltage  
measuring capability of an ac/dc voltmeter to 6000 volts peak AC  
or DC Overvoltage Category I. This means the probe can only be  
used to make measurements on energy limited circuits within  
equipment. Examples include high voltage within televisions or  
photo copy machines. DO NOT use this probe to measure high  
voltages on power distribution systems. A 1000:1 voltage divider  
provides the probe with a high input impedance. The divider also  
provides high accuracy when used with a voltmeter having a 10  
megohm input impedance. A molded plastic body houses the  
divider and protects the user from the voltage being measured.  
Fluke authorized resellers shall extend this warranty on new and unused  
products to end-user customers only but have no authority to extend a  
greater or different warranty on behalf of Fluke. Warranty support is  
available if product is purchased through a Fluke authorized sales outlet  
or Buyer has paid the applicable international price. Fluke reserves the  
right to invoice Buyer for importation costs of repair/replacement parts  
when product purchased in one country is submitted for repair in another  
country.  
Fluke’s warranty obligation is limited, at Fluke’s option, to refund of the  
purchase price, free of charge repair, or replacement of a defective  
product which is returned to a Fluke authorized service center within the  
warranty period.  
Specifications  
The 80K-6 will achieve rated accuracy when it is used with an  
ac/dc voltmeter having 0.25% accuracy, or better, and an input  
impedance of 10 megohms ±10%. Specifications for the probe  
are as follows:  
To obtain warranty service, contact your nearest Fluke authorized service  
center or send the product, with a description of the difficulty, postage and  
insurance prepaid (FOB Destination), to the nearest Fluke authorized  
service center. Fluke assumes no risk for damage in transit. Following  
warranty repair, the product will be returned to Buyer, transportation  
prepaid (FOB Destination). If Fluke determines that the failure was  
caused by misuse, alteration, accident or abnormal condition of operation  
or handling, Fluke will provide an estimate of repair costs and obtain  
authorization before commencing the work. Following repair, the product  
will be returned to the Buyer transportation prepaid and the Buyer will be  
billed for the repair and return transportation charges (FOB Shipping  
Point).  
Voltage Range:  
Input Impedance:  
Division Ratio:  
Accuracy:  
0 to 6 kV, dc or peak ac  
75 megohms nominal  
1000:1  
DC to 500 Hz:  
500 Hz to 1 kHz:  
Above 1 kHz:  
±1%  
±2%  
Output reading falIs.  
Typically, -30% at 10 kHz.  
Temperature:  
Storage:  
-20 to 60°C  
0 to 50°C  
Operating:  
Temperature Coefficient: 100 ppm/C  
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND  
IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,  
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,  
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES,  
INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF  
WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY  
OTHER THEORY.  
Relative Humidity:  
Altitude:  
20 - 80%  
2000 m  
Shock and Vibration:  
Shock:  
1 m Drop  
Vibration:  
Dimensions:  
5-55 Hz swept sine 3 g max.  
24.89 cm (9.8 in) (probe body), 5.10  
cm (2.0 in) max. width  
12.7 g (45 oz)  
Weight:  
Safety:  
CAN/CSA C22.2 No. 1010.2.031-94 & IEC 1010-2-031:1993,  
Type B, 6 kVDC or peak AC, 4.24 kV rms AC, Overvoltage  
Cat. I (Voltage derived from limited energy transformers).  
Since some countries or states do not allow limitation of the term of an  
implied warranty, or exclusion or limitation of incidental or consequential  
damages, the limitations and exclusions of this warranty may not apply to  
every buyer. If any provision of this Warranty is held invalid or  
unenforceable by a court of competent jurisdiction, such holding will not  
affect the validity or enforceability of any other provision.  
Measurement Considerations  
Before attempting to use the 80K-6, the following paragraphs  
should be read and understood. Particular attention should be  
given to Operator Safety.  
Fluke Corporation  
P.O. Box 9090  
Everett, WA 98206-9090  
U.S.A.  
Fluke Europe B.V.  
P.O. Box 1186  
5602 BD Eindhoven  
The Netherlands  
Operator Safety  
Indicates the operator must refer to an explanation in  
this manual.  
Indicates terminals at which lethal voltages may exist.  
P/N 613224  
April 1981 Rev.6, 11/01  
© 1981-2001 Fluke Corporation, All rights reserved. Printed in U.S.A.  
All product names are trademarks of their respective companies.  
5/94  
 

Exido Hot Beverage Maker 245 046 User Manual
Exmark Lawn Mower 4500 466 User Manual
Fisher Paykel Stove CG602 User Manual
Fisher Price Baby Toy V7505 User Manual
Fujitsu Printer FTP 628MCL113 User Manual
Fusion Marine Instruments MS RA50 User Manual
GE Freezer FCM7DM User Manual
GE Network Router A8950CC User Manual
Global Machinery Company Power Hammer MRHD1500CF User Manual
Goodman Mfg Air Conditioner IO 354B User Manual