Safety Information
Owner’s Manual and
Adapter Plugs . . . . . . . . . . . . . . . . . . 4
Connecting Electricity . . . . . . . . . . .3
Extension Cords . . . . . . . . . . . . . . . . 4
Safety Precautions . . . . . . . . . . . . . . 2
Installation Instructions
Chassis Only
Cool Only: AJCH 08, 10
AJCH 10, 12
ACA
DCA
LCA
ACA
Operating Instructions
Air Direction . . . . . . . . . . . . . . . . . . . 6
Controls . . . . . . . . . . . . . . . . . . . . . 5, 6
Fan Switch . . . . . . . . . . . . . . . . . . . . . 6
Temperature Limiting . . . . . . . . . .6
Vent Control . . . . . . . . . . . . . . . . . . .6
AJCS 06
AJCS 08, 10
AJCS 09, 10, 12 DCA
Heat/Cool: AJES 09, 10, 12 DCA
Care and Cleaning
AJEH 12
DCA
DCA
Air Filter . . . . . . . . . . . . . . . . . . . . . . . 8
Front Grille . . . . . . . . . . . . . . . . . . . . .7
Grille and Case . . . . . . . . . . . . . . . . . 7
Outdoor Coils . . . . . . . . . . . . . . . . . . 7
Heat Pump: AJHS 08, 10
Installation
Installing a J-Model in an
Existing Wall Case . . . . . . . . . . 10–12
Preparing to Install . . . . . . . . . . . . . 9
Troubleshooting Tips
Before You Call For Service . . . . 14
Normal Operating Sounds . . . . . 14
Consumer Support
Consumer Support . . . . Back Cover
Warranty . . . . . . . . . . . . . . . . . . . . . 15
Write the model and serial numbers here:
# ________________________________
# ________________________________
Find these numbers on a label on the
front of the base pan behind the front grille.
49-7397 10-00 JR
SafeyIructions
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safety, this appliance must be properly grounded.
OpeagIructions
The power cord of this appliance is equipped The air conditioner should always be
with a 3-prong (grounding) plug which mates plugged into its own individual electrical
with a standard 3-prong (grounding) wall
outlet to minimize the possibility of electric
shock hazard from this appliance.
outlet which has a voltage rating that matches
the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is which could cause a fire hazard from
properly grounded.
overheated wires.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and
See the Installation Instructions, Electrical
Requirements section for specific electrical
rdCleaing
obligation to have it replaced with a properly connection requirements.
grounded 3-prong wall outlet.
laIructions
T
rubleshotingT
ips
CnsmeSuport
3
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
USE OF EXTENSION CORDS–115-Volt models only
SafeyIructions
Because of potential safety hazards under
CAUTION:
DO NOT use an extension cord with any of
the 230/208 volt models.
certain conditions, we strongly recommend
against the use of an extension cord.
However, if you must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14 gauge, 3-wire grounding type appliance
extension cord having a grounding type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 volts.
OpeagIructions
USE OF ADAPTER PLUGS –115-Volt models only
Because of potential safety hazards under
certain conditions, we strongly recommend
against the use of an adapter plug.
When disconnecting the power cord from
the adapter, always hold the adapter in place
with one hand while pulling the power cord
plug with the other hand. If this is not done,
the adapter ground terminal is very likely to
break with repeated use.
However, if you must use an adapter, where
local codes permit, a temporary connection
may be made to a properly grounded 2-prong
wall outlet by use of a UL-listed adapter
available at most local hardware stores.
rdCleaing
If the adapter ground terminal breaks, DO
NOT USE the air conditioner until a proper
ground has been established.
The larger slot in the adapter must be aligned
with the larger slot in the wall outlet to
provide proper polarity in the connection
of the power cord.
Attaching the adapter ground terminal to a wall
outlet cover screw does not ground the appliance
unless the cover screw is metal, and not insulated,
and the wall outlet is grounded through the house
wiring. You should have the circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
laIructions
ips
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
rubleshotingT
T
CnsmeSuport
4
SafeyIructions
About the controls on the air conditioner.
LOW
FAN
HIGH
OFF
FAN
LOW
LOW
HEAT
COOL
HIGH
HEAT
HIGH
COOL
OpeagIructions
OFF
LOW
FAN
LOW
COOL
HIGH
FAN
HIGH
COOL
rdCleaing
MODE CONTROL
TEMP CONTROL
laIructions
Controls
Mode Control
Temp Control
HIGH COOL and LOW COOL provide cooling
with different fan speeds.
The temp control is used to maintain the
room temperature. The compressor will
cycle on and off to keep the room at the
same level of comfort. When you turn
the knob to COOLER (blue) the indoor air
will become cooler. Turn the knob to
WARMER (red) and the indoor air will
become warmer.
HIGH HEAT and LOW HEAT provide heating
with different fan speeds.
LOW FAN or HIGH FAN provides air
circulation and filtering without cooling
or heating.
T
rubleshotingT
NOTE: If you move the switch from a cool or heat
setting to OFF or to a fan setting, wait at least 3
minutes before switching back to a cool or heat
setting. A 3-minute delay is automatically provided
on the Heat/Cool and Heat Pump models.
Heat Pump Models
When the outdoor temperature is lower
than 25°F., heat is provided by the electric
heater in the air conditioner instead of by
the heat pump.
ips
Cooling/Heating Descriptions
NOTE: The electric resistance heater in the 115-volt
heat pump model operates during defrost when the
outdoor coil temperature is below 36°F. It is not
intended to provide full heat capability.
For Normal Cooling or Heating—Select
HIGH COOL or HIGH HEAT with the
thermostat at mid point.
CnsmeSuport
For Maximum Cooling—Select HIGH COOL
with the thermostat at maximum cool.
For Maximum Heating—Select HIGH HEAT
with the thermostat at maximum heat.
For Quieter & Nighttime Cooling—Select
LOW COOL with the thermostat at mid
point.
5
About the controls on the air conditioner.
Fan Switch
On Heat/Cool models, the fan switch lever is
located in a hole through the control panel. To
reach it, you need to remove the front grille. Use
a small screwdriver to change the setting. Cool
only models have a rocker switch on the front of
the control box.
SafeyIructions
When set at CYCLE (down) the fan cycles on and
off when cooling or heating. When set at CONT
(continuous, up) the fan runs all the time. The
unit is shipped in the CONT setting.
OpeagIructions
Temperature Limiting
Limiting the maximum and minimum settings
prevents users from turning the control to the
extreme heat or cool positions.
The normal range of the temp control is
approximately 60°F to 85°F. The control range
may be narrowed by the use of the temperature
limiting screws located behind the control panel.
Limits
heat
temp
Limits
cool
temp
rdCleaing
Each position equals approximately 3°F.
Vent Control
The vent control is located behind the front grille
on the right side of the air discharge area. When
set at CLOSE, only the air inside the room will be
circulated and conditioned. When set at OPEN,
some inside air is exhausted outside.
laIructions
To open or close the vent:
1. Remove the front grille.
Open
ips
Close
2. Remove and replace the vent card to the OPEN
(mesh end toward the back) or to the CLOSE
(mesh end toward the front) position.
rubleshotingT
Air Direction
T
Horizontal louvers
on the front grille
let you control the
air direction up
and down.
Remove the front
grille to adjust the
vertical louvers
side-to-side to
direct the air left
or right.
CnsmeSuport
6
SafeyIructions
Care and cleaning of the air conditioner.
Grille and Case
Turn the air conditioner off and remove the
plug from the wall outlet before cleaning.
To clean, use water and a mild detergent.
Do not use bleach or abrasives.
OpeagIructions
Outdoor Coils
The coils on the outdoor side of the air
conditioner should be checked regularly.
If they are clogged with dirt or soot they may be
professionally steam cleaned, a service available
through your GE service outlet.
rdCleaing
Front Grille
The front grille can be removed for more
thorough cleaning or to make the model and
serial numbers accessible.
3. Pull the grille out from the bottom and lift up
from the tabs on the top of the case.
Grille
To remove:
laIructions
1. Pull the filter out.
2. Remove the two grille screws.
Tab
On some models
T
rubleshotingT
To replace:
Hook the tabs on the front grille even with the
tabs on the case and snap into place.
Replace the screws and filter.
On some models
ips
Grille
CnsmeSuport
Tab
7
Care and cleaning of the air conditioner.
To maintain optimum performance, clean the filter at least every 30 days.
Air Filter
To remove the air filter, on other models:
FRONT
FRONT
SafeyIructions
Pull it down.
Dirty filter—Needs cleaning
Clogged filter—Greatly
reduces cooling, heating
and airflow.
Turn the air conditioner off before cleaning.
The most important thing you can do to maintain
the air conditioner is to clean the filter at least
every 30 days. A clogged filter reduces cooling,
heating and air flow.
OpeagIructions
To replace the air filter:
Replace the clean filter by pushing it back
into place.
Keeping the air filter clean will:
■Decrease cost of operation.
■Save energy.
■Prevent clogged heat exchanger coils.
rdCleaing
■Reduce the risk of premature component
failure.
To clean the air filters:
■Vacuum off the heavy soil.
■Run water through the filters.
■Dry thoroughly before replacing.
To remove the air filter, on some models:
Carefully pull the tab forward, up and out.
CAUTION: Do not operate the air conditioner
without the filter in place. If a filter becomes torn or
damaged it should be replaced immediately.
Operating without the filter in place or with a
damaged filter will allow dirt and dust to reach
the indoor coil and reduce the cooling, heating,
airflow and efficiency of the unit.
laIructions
ips
Replacement filters are available from your
salesperson, GE dealer, GE Service and Parts
Center or authorized Customer Care® servicers.
rubleshotingT
T
CnsmeSuport
8
SafeyIructions
Preparing to install the air conditioner.
Read these instructions completely and carefully.
Before You Begin
NOTE TO INSTALLER: Leave these instructions
with the air conditioner after installation is
completed.
CAUTION:
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
OpeagIructions
NOTE TO CONSUMER: Keep this Owner’s
Manual and Installation Instructions for future
use.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
IMPORTANT NOTES:
For personal safety, this air conditioner must be
properly grounded.
It is important to have the wall outlet and circuit
checked by a qualified electrician if there is any
doubt as to whether a proper ground exists.
rdCleaing
Follow National Electric Codes (NEC) and/or
local codes and ordinances.
Electrical Requirements
Some models require 115/120-volt a.c.,
60 Hz grounded outlet protected with
a 15-amp time delay fuse or circuit
breaker.
Some models require 230/208-volt
a.c., protected with a time delay fuse
or circuit breaker. These models
should be installed on their own single
branch circuit for best performance
and to prevent overloading house
or apartment wiring circuits, which
could cause a possible fire hazard
from overheating wires.
laIructions
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall
outlet you plan to use is only a 2-prong outlet, it is
your responsibility to have it replaced with a
properly grounded 3-prong wall outlet.
T
rubleshotingT
ips
CnsmeSuport
9
Installing a J-Model in an existing wall case.
Read these instructions completely and carefully.
IMPORTANT!
SafeyIructions
GE strongly recommends the removal of the old
wall case and the installation of a new GE Wall
Case. If you decide to keep the existing wall
case, you may need a kit to ensure proper
performance. If you DO NOT use a kit, you
run the risk of poor performance or product
failure. This is not covered under the terms
of the GE warranty.
OpeagIructions
J-Model Qualifying Questions
J-model air conditioners may fit in existing wall
cases. However, they often need a kit to properly
adapt the case to the GE air conditioner. Answer
these questions and see the chart below for the
proper kit.
What brand air conditioner will you be
replacing?
A
rdCleaing
What are the dimensions of the wall case
currently in use?
B
What is the model number of the chassis
C
currently in use? What is the model (or Type)
number of the wall case currently in use?
Frequently, the J-model adapter kit will apply
to another brand model “series” or specific
vintage. In these cases, you need the chassis
model number and/or the wall case or “type”
number to confirm the use of the correct
adapter kit.
laIructions
What type of outdoor grille is used with the
current wall case?
ips
D
There may be an architectural grille attached
to a wall case to enhance the exterior
appearance of the building. Custom grilles
may be used with J-model wall cases provided
a J-model adapter kit is also used to ensure
proper airflow.
rubleshotingT
T
CnsmeSuport
10
SafeyIructions
Read these instructions completely and carefully.
GE Kit Numbers
Use GE
Kit Number:
For:
Description:
OpeagIructions
RAK56A100
GE RAB13, 14 & 15
(ACLB & RCL Chassis)
Fits all GE wall cases 26″W x 18″H x 24″D
RAK107
Hotpoint ACXB10 & 11
(ACTB Chassis)
Adapts an older Hotpoint wall case to a “J”
model chassis. Fits Hotpoint wall cases
253⁄4″W x 167⁄8″H x 185⁄8″D
RAK108
Whirlpool Type 23W
Wall Case
Adapts Whirlpool wall case to a “J”
model chassis. Fits Whirlpool wall
cases 257⁄8″W x 161⁄2″H x 231⁄8″D
RAK110
RAK123
RAK126
GE RAB30
(“F” models)
Adapts GE wall case to a “J” model chassis.
Fits the RAB 30 wall case 26″W x 18″H x 24″D
rdCleaing
Fedders Wall Case “A”
Adapts Fedders wall case to a “J” model chassis.
Fits Fedders wall cases 27″W x 163⁄4″H x 163⁄4″D
Westinghouse Wall Case
(Type 2626D73H01)
Adapts Westinghouse wall case to a “J”
model chassis. Fits Westinghouse wall
cases 257⁄8″W x 157⁄16″H x 16″D
RAB46, 47 & 48
Use these kits for all
other brands not listed.
Standard wall case for “J” model chassis.
RAG13 stamped aluminum exterior grille
included. Remove the existing case
and replace.
laIructions
RAK690
RAG14E
RAB36, 37, 38, 46, 47 or 48
(J-Chassis)
If you attach a custom architectural outdoor
grille, use this kit to ensure proper airflow.
RAB36, 37, 38, 46, 47 or 48
(J-Chassis)
Architectural louvered exterior grille
T
rubleshotingT
ips
CnsmeSuport
11
Installing a J-Model in an existing wall case.
Read these instructions completely and carefully.
Install the Air Conditioner in the Case.
Remove the locking plate on the front
left side.
Reinstall the locking plate with the tab
behind the wall case flange. Tighten
the screw.
A
D
E
SafeyIructions
Attach the power cord to the base pan
with the clamp.
Locking
plate
Remove
screw
Base pan
Power cord
Clamp
OpeagIructions
Remove the shipping pad inside the air
conditioner next to the compressor.
B
When the wall outlet is to the left, extend the
cord under the unit and hold it in place with
the clamp.
F
rdCleaing
Remove
shipping pad
Power cord
Clamp
Carefully slide the air conditioner back into
the case. Make sure that the tubing on the
unit does not touch the wall case and that the
case installation is secure.
C
Attach the front grille. An opening for
the power cord is on the bottom of the
front grille.
G
laIructions
ips
rubleshotingT
T
CnsmeSuport
12
SafeyIructions
Notes.
OpeagIructions
rdCleaing
laIructions
T
rubleshotingT
ips
CnsmeSuport
13
Before You Call For Service…
Troubleshooting Tips
Save time and money! Review the chart on this page
first and you may not need to call for service.
SafeyIructions
Problem
Possible Causes
What To Do
Air conditioner
does not start
The air conditioner
is unplugged.
• Make sure the air conditioner plug is pushed completely
into the outlet.
The fuse is blown/circuit
breaker is tripped.
• Check the house fuse/circuit breaker box and replace
the fuse or reset the breaker.
Power failure.
• If power failure occurs, turn the mode control to
OFF. When power is restored, wait 3 minutes to restart
the air conditioner to prevent tripping of the
compressor overload.
OpeagIructions
Air conditioner does
not cool as it should
Airflow is restricted.
• Make sure there are no curtains, blinds or furniture
blocking the front of the air conditioner.
The temp control may not
be set high or low enough.
• Turn the knob to a warmer or cooler setting. The coolest
setting provides maximum cooling. The warmest setting
provides maximum heating on models with heat.
The air filter is dirty.
• Clean the filter at least every 30 days. See the Care and
cleaning of the air conditioner section.
rdCleaing
The room may have been hot
or cold.
• When the air conditioner is first turned on you need to
allow time for the room to cool down or warm up.
Cold air is escaping.
• Check for open furnace floor registers and cold
air returns.
• Set the air conditioner’s vent to the closed position.
• See “Air conditioner freezing up” below.
Cooling coils have iced up.
Air conditioner
freezing up
Ice blocks the air flow
and stops the air conditioner
from cooling the room.
• Set the mode control at HIGH FAN or HIGH COOL
with the temp at a warmer setting.
laIructions
ips
Normal Operating Sounds
■ You may hear a pinging noise caused
by water being picked up and thrown
against the condenser on rainy days or
when the humidity is high. This design
feature helps remove moisture and
improve efficiency.
■ Water will collect in the base pan
during high humidity or on rainy days.
The water may overflow and drip from
the outdoor side of the unit.
■ The fan may run even when the
compressor is not.
rubleshotingT
T
■ You may hear the thermostat click
when the compressor cycles on and off.
CnsmeSuport
14
SafeyIructions
Air Conditioner Warranty.
All warranty service provided by our Factory Service
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
®
Centers, or an authorized Customer Care technician.
To schedule service, on-line, 24 hours a day, contact
OpeagIructions
For The Period Of:
GE Will Replace:
One Year
From the date of the
original purchase
Any part of the air conditioner which fails due to a defect in materials or workmanship.
During this full one-year warranty, GE will also provide, free of charge, all labor
and in-home service to replace the defective part.
Five Years
From the date of the
original purchase
Any part of the sealed refrigerating system (the compressor, condenser, evaporator
and all connecting tubing) which fails due to a defect in materials or workmanship.
During this additional four-year limited warranty, GE will also provide, free of charge, all
labor and in-home service to replace the defective part.
rdCleaing
What GE Will Not Cover:
■Service trips to your home to teach you how to use the
product.
■Replacement of house fuses or resetting of circuit
breakers.
■Improper installation. If you have an installation
problem, or if the air conditioner is of improper cooling
capacity for the intended use, contact your dealer or
installer. You are responsible for providing adequate
electrical connecting facilities.
■Failure due to corrosion on models not corrosion-
protected.
■Damage to the product caused by improper power
supply voltage, accident, fire, floods or acts of God.
laIructions
■Incidental or consequential damage caused by possible
defects with this air conditioner.
■Failure of the product resulting from modifications to
the product or due to unreasonable use including
failure to provide reasonable and necessary
maintenance.
■In commercial locations labor necessary to move the
unit to a location where it is accessible for service by an
individual technician.
T
This warranty is extended to the original purchaser and any succeeding owner for products purchased for
home use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
rubleshotingT
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty
gives you specific legal rights, and you may also have other rights which vary from state to state. To know
what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
ips
Warrantor: General Electric Company. Louisville, KY 40225
CnsmeSuport
15
Consumer Support.
GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day,
any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals,
order parts, catalogs, or even schedule service on-line. You can also “Ask Our Team of Experts™”
your questions, and so much more...
Schedule Service
Expert GE repair service is only one step away from your door. Get on-line and schedule your service at
your convenience 24 hours any day of the year! Or call 800-GE-CARES (800-432-2737) during normal
business hours.
Real Life Design Studio
GE supports the Universal Design concept—products, services and environments that can be used by
people of all ages, sizes and capabilities. We recognize the need to design for a wide range of physical and
mental abilities and impairments. For details of GE’s Universal Design applications, including kitchen
design ideas for people with disabilities, check out our Website today. For the hearing impaired, please call
800-TDD-GEAC (800-833-4322).
Extended Warranties
Purchase a GE extended warranty and learn about special discounts that are available while your warranty
is still in effect. You can purchase it on-line anytime, or call 800-626-2224 during normal business hours.
GE Consumer Home Services will still be there after your warranty expires.
Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes
(VISA, MasterCard and Discover cards are accepted). Order on-line today, 24 hours every day or by phone at
800-626-2002 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally
should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause
unsafe operation.
Contact Us
If you are not satisfied with the service you receive from GE, contact us on our Website with all the details
including your phone number, or write to: General Manager, Customer Relations
GE Appliances, Appliance Park
Louisville, KY 40225
Register Your Appliance
Register your new appliance on-line—at your convenience! Timely product registration will allow for
enhanced communication and prompt service under the terms of your warranty, should the need arise.
You may also mail in the pre-printed registration card included in the packing material, or detach and
use the form in this Owner’s Manual.
Printed in China
|