STANDBY GENERATORS
8 kW - 10 kW - 14 kW
Air-Cooled Gas Engine Generator Sets
Continuous Standby Power Rating
Model 005518-1 (Steel - Bisque) - 8 kW 60Hz
Model 005520-1 (Steel - Bisque) - 10 kW 60Hz
Model 005522-1 (Steel - Bisque) - 14 kW 60Hz
Includes:
®
• True Power Electrical Technology
• Two Line LCD Digital Controller
(10 kW & 14 kW)
• Electronic Governor
(10 kW & 14 kW)
• External Main Circuit Breaker
& System Status LED
(10 kW & 14 kW)
• Flexible Fuel Line Connector
• Composite Mounting Pad
• Natural Gas or LP Gas Operation
• UL 2200 Listed
FEATURES
¡
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC’S success in “IMPROVING POWER BY DESIGN.”
But it doesn’t stop there. Total commitment to component testing,
reliability testing, environmental testing, destruction and life testing,
plus testing to applicable CSA, NEMA, EGSA, and other standards,
allows you to choose GENERAC POWER SYSTEMS with the
confidence that these systems will provide superior performance.
¡
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.
¡
¡
SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component.
¡
¡
TRUE POWER® ELECTRICAL TECHNOLOGY: Superior harmonics
and sine wave form produce less than 5% Total Harmonic Distortion for
utility quality power. This allows confident operation of sensitive electronic
equipment and micro-chip based appliances, such as variable speed HVAC.
GENERAC TRANSFER SWITCHES. Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
TEST CRITERIA:
PROTOTYPE TESTED
NEMA MG1-22 EVALUATION
MOTOR STARTING ABILITY
SYSTEM TORSIONAL TESTED
®
®
SPECIFICATIONS
GENERATOR
Model 05518 (8 kW)
Model 05520 (10 kW)
Model 05522 (14 kW)
Rated Maximum Continuous Power Capacity (LP)
8,000 Watts*
7,000 Watts*
120/240
10,000 Watts*
9,000 Watts*
120/240
14,000 Watts*
13,000 Watts*
120/240
Rated Maximum Continuous Power Capacity (NG)
Rated Voltage
Rated Maximum Continuous Load Current
240 Volts
Total Harmonic Distortion
Main Line Circuit Breaker
Phase
33.3 LP/29.2 NG
Less than 5%
35 Amp
41.6 LP/37.5 NG
Less than 5%
45 Amp
58.3 LP/54.2 NG
Less than 5%
60 Amp
1
1
1
Number of Rotor Poles
Rated AC Frequency
2
2
2
60Hz
60Hz
60Hz
Power Factor
1
1
1
Battery Requirement (not included)
Group 26R
12 Volts and
350 Cold-cranking
Amperes Minimum
340 Pounds
48 x 25 x 29
62
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
387 Pounds
48 x 25 x 29
63
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
439 Pounds
48 x 25 x 29
66
Unit Weight
Dimensions (L” x W” x H”)
Sound output in dB(A) at 23 ft. with generator operating at normal load
ENGINE
Model 05518 (8 kW)
Model 05520 (10 kW)
Model 05522 (14 kW)
Type of Engine
Number of Cylinders
Rated Horsepower
Displacement
GENERAC OHVI
GENERAC OHVI V-TWIN
GENERAC OHVI V-TWIN
1
14.8 @ 3,600 rpm
410cc
2
18 @ 3,600 rpm
530cc
2
32 @ 3,600 rpm
992cc
Cylinder Block
Aluminum w/Cast
Iron Sleeve
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
Aluminum w/Cast
Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
Valve Arrangement
Ignition System
Overhead Valve
Solid-state w/Magneto
Mechanical
Governor System
Compression Ratio
Starter
9.4:1
12 Vdc
9.5:1
12 Vdc
9.5:1
12 Vdc
Oil Capacity Including Filter
Operating RPM
Approx. 1.5 Qts.
3,600
Approx. 1.7 Qts.
3,600
Approx. 1.9 Qts.
3,600
Fuel Consumption
Natural Gas
cu.ft./hr.
1/2 Load
Full Load
77
139
102
156
156
220
3
Liquid Propane
ft /hr (gal/hr)
1/2 Load
Full Load
34 (0.94)
62 (1.68)
46 (1.25)
70 (1.93)
58 (1.56)
84 (2.30)
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
CONTROLS
2-Line Plain Text LCD Display (10 & 14 kW)
Simple user interface for ease of operation
Mode Switch
-Auto
Automatic Start on Utility failure. 7 day exerciser
-Off
Stops unit. Power is removed. Control and charger still operate.
-Manual/Test (start)
Engine Start Sequence
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration)
Engine Warm-up
10 seconds
Engine Cool-Down
1 minute
Starter cannot re-engage until 5 sec. after engine has stopped.
Starter Lock-out
2.5 Amp Timed Trickle Battery Charger
Automatic Voltage Regulator w/Overvoltage Protection
Automatic Low Oil Pressure Shutdown
Overspeed Shutdown
Standard
Standard
Standard
Standard, 72Hz
Standard
High Temperature Shutdown
Overcrank Protection
Standard
Safety Fuse
Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Standby Generator - 8 kW - 10 kW - 14 kW
Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
637.6
[25.1]
1218
[47.9]
731.9
[28.8]
642
[25.3]
76.2 [3.0]
PEA GRAVEL
MINIMUM
1226
[48.3]
FRONT VIEW
LEFT SIDE VIEW
®
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
©2009 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0181640SBY-A Printed in U.S.A. 08/27/09
|