GS-705N Shear Lock Installation Instruction
Unbalanced air conditioning (stack pressure) can hinder door alignment and must be corrected to help insure positive locking. It
is important to note that the Shear Locks need a regulated 12V DC (or 24VDC) at the lock, and use the highest quality door closer
only. Positive centering door closers are required for all double acting door applicators to help attain consistent dead center
alignment. Also the door latching problems must be corrected prior to installation.
Specifications
Up to 2700 lbs (1226 Kg) in shear.
Holding Force
Power Input
Magnet Assembly
12/24 VDC selectable via jumpers +10%
over voltage is acceptable , under voltage
will reduce holding force.
0.35 A@12 VDC; 0.17 A@24 VDC The unit
does not require initial voltage increase to
operate.
Current Draw
Locking Bolt
Keep Hole
Push-off button
Keep Hole
Finish
Magnet and Armature: Zinc plated
Housing: Black powder coated
Magnet bond sensor output, SPDT rating
1 AMP@30 VDC
Monitoring Output
Armature vertical
adjustment screws
Door Gap
2mm
Armature Assembly
Operating Temper.
-30C to +50C
Connecting Diagram
Magnet bond sensor output
SPDT relay : 1A@30 VDC
Caution:
N.C.
Make sure that the "+" and "-"
wire are connected correctly.
Failure to observe polarity will
result in a short circuit and is
not covered by products
warrant.
COM.
12Vdc
24Vdc
N.O.
Voltage Selection jumpers
Check jumper settings before
connecting the lock to 24 VDC
input power. Damage to the
lock may result from incorrect
jumper settings.
-
+
-
Power
+
supply
Control Device
N.C. contact or Access Relay
Dimensions
6
Install the magnet assembly into the door
frame before installation the armature assembly
into the door leaf. The magnet assembly requires
space to run wires, as wall as space for the
recesses portion of the unit. However, make sure
that the position selected for the magnet
assembly leaves enough room on the door to
install the armature assembly.
GS-705N-30
32
30
251
267
Locking Bolt
5.9
30
3.5
Unit: mm
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-GS705N-30 Ver. C Publish:2007.07.17
2-1
|