Instructions
Parts
28:1/33:1 RATIO, WALL MOUNT
Bulldogr Pumps
307932R
For ambient temperature spray applications.
Part No. 245187, 33:1, Series B
3300 psi (22.8 MPa, 228 bar) Maximum Fluid Working Pressure
100 psi (700 kPa, 7 bar) Maximum Air Input Pressure
Part No. 253697, 28:1, Series A
2800 psi (19.3 MPa, 193 bar) Maximum Fluid Working Pressure
100 psi (700 kPa, 7 bar) Maximum Air Input Pressure
Part No. 245185, Series B (240 Volt Heater)
Part No. 245186, Series B (480 Volt Heater)
For heated spray applications.
3000 psi (20.7 MPa, 207 bar) Maximum Fluid
Working Pressure
90 psi (600 kPa, 6 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for Table of Contents.
4414B
Model 245187 Shown
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
Copyright 1998, Graco Inc. is registered to I.S. EN ISO 9001
WARNING
SKIN INJECTION HAZARD
Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely
serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also
cause serious injury.
D
F
l
u
i
d
i
n
j
e
c
t
e
d
i
n
t
o
t
h
e
s
k
i
n
m
i
g
h
t
l
o
o
k
l
i
k
e
j
u
s
t
a
c
u
t
,
b
u
t
i
t
i
s
a
s
e
r
i
o
u
s
i
n
j
u
r
y
.
G
e
t
i
m
m
e
d
i
a
t
e
s
u
r
g
i
-
cal treatment.
D Do not point the gun at anyone or at any part of the body.
D Do not put your hand or fingers over the spray tip.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Do not “blow back” fluid; this is not an air spray system.
D Always have the tip guard and the trigger guard on the gun when spraying.
D Check the gun diffuser operation weekly. Refer to the gun manual.
D Be sure the gun trigger safety operates before spraying.
D Lock the gun trigger safety when you stop spraying.
D
F
o
l
l
o
w
t
h
e
P
r
e
s
s
u
r
e
R
e
l
i
e
f
P
r
o
c
e
d
u
r
e
o
n
p
a
g
e
1
4
i
f
t
h
e
s
p
r
a
y
t
i
p
c
l
o
g
s
a
n
d
b
e
f
o
r
e
c
l
e
a
n
i
n
g
,
checking or servicing the equipment.
D
T
i
g
h
t
e
n
a
l
l
f
l
u
i
d
c
o
n
n
e
c
t
i
o
n
s
b
e
f
o
r
e
o
p
e
r
a
t
i
n
g
t
h
e
e
q
u
i
p
m
e
n
t
.
D
C
h
e
c
k
t
h
e
h
o
s
e
s
,
t
u
b
e
s
,
a
n
d
c
o
u
p
l
i
n
g
s
d
a
i
l
y
.
R
e
p
l
a
c
e
w
o
r
n
o
r
d
a
m
a
g
e
d
p
a
r
t
s
i
m
m
e
d
i
a
t
e
l
y
.
Do not repair high pressure couplings; you must replace the entire hose.
D
U
s
e
o
n
l
y
G
r
a
c
o
a
p
p
r
o
v
e
d
h
o
s
e
s
.
D
o
n
o
t
r
e
m
o
v
e
t
h
e
s
p
r
i
n
g
g
u
a
r
d
t
h
a
t
i
s
u
s
e
d
t
o
h
e
l
p
p
r
o
t
e
c
t
t
h
e
hose from rupture caused by kinks or bends near the couplings.
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
D
K
e
e
p
c
l
e
a
r
o
f
a
l
l
m
o
v
i
n
g
p
a
r
t
s
w
h
e
n
s
t
a
r
t
i
n
g
o
r
o
p
e
r
a
t
i
n
g
t
h
e
p
u
m
p
.
D
B
e
f
o
r
e
s
e
r
v
i
c
i
n
g
t
h
e
e
q
u
i
p
m
e
n
t
,
f
o
l
l
o
w
t
h
e
P
r
e
s
s
u
r
e
R
e
l
i
e
f
P
r
o
c
e
d
u
r
e
o
n
p
a
g
e
1
4
t
o
p
r
e
v
e
n
t
t
h
e
equipment from starting unexpectedly.
307932
3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
D
G
r
o
u
n
d
t
h
e
e
q
u
i
p
m
e
n
t
a
n
d
t
h
e
o
b
j
e
c
t
b
e
i
n
g
s
p
r
a
y
e
d
.
R
e
f
e
r
t
o
G
r
o
u
n
d
i
n
g
o
n
p
a
g
e
5
.
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing immediately. Do not use the equipment until you identify and correct the problem.
D
P
r
o
v
i
d
e
f
r
e
s
h
a
i
r
v
e
n
t
i
l
a
t
i
o
n
t
o
a
v
o
i
d
t
h
e
b
u
i
l
d
u
p
o
f
f
l
a
m
m
a
b
l
e
f
u
m
e
s
f
r
o
m
s
o
l
v
e
n
t
s
o
r
t
h
e
f
l
u
i
d
being sprayed.
D Keep the spray area free of debris, including solvent, rags, and gasoline.
D Electrically disconnect all equipment in the spray area.
D Extinguish all open flames or pilot lights in the spray area.
D Do not smoke in the spray area.
D Do not turn on or off any light switch in the spray area while operating or if fumes are present.
D Do not operate a gasoline engine in the spray area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
D
K
n
o
w
t
h
e
s
p
e
c
i
f
i
c
h
a
z
a
r
d
s
o
f
t
h
e
f
l
u
i
d
y
o
u
a
r
e
u
s
i
n
g
.
D
S
t
o
r
e
h
a
z
a
r
d
o
u
s
f
l
u
i
d
i
n
a
n
a
p
p
r
o
v
e
d
c
o
n
t
a
i
n
e
r
.
D
i
s
p
o
s
e
o
f
h
a
z
a
r
d
o
u
s
f
l
u
i
d
a
c
c
o
r
d
i
n
g
t
o
a
l
l
l
o
c
a
l
,
state and national guidelines.
D
A
l
w
a
y
s
w
e
a
r
p
r
o
t
e
c
t
i
v
e
e
y
e
w
e
a
r
,
g
l
o
v
e
s
,
c
l
o
t
h
i
n
g
a
n
d
r
e
s
p
i
r
a
t
o
r
a
s
r
e
c
o
m
m
e
n
d
e
d
b
y
t
h
e
f
l
u
i
d
a
n
d
solvent manufacturer.
4
307932
Installation
General Information
W
X
Z
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
45
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. Refer to
the Product Data Sheet for your pump, Form No.
305791. If you supply your own accessories, be sure
they are adequately sized and pressure rated for your
system.
0864
Fig. 1
2. Air and fluid hoses: use only electrically conductive
hoses.
NOTE: Fig. 2 is only a guide for selecting and installing
system components and accessories. Contact your
Graco distributor for assistance in designing a system
to suit your particular needs.
3. Heaters, if used: refer to Viscon HP Heater manu-
al, 309524.
4. Air compressor: follow manufacturer’s recommen-
dations.
Grounding
5. Spray gun: ground through connection to a prop-
erly grounded fluid hose and pump.
WARNING
6. Fluid supply container: follow your local code.
7. Object being sprayed: follow your local code.
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION HAZ-
ARD on page 4.
8. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
1. Pump: use a ground wire and clamp (supplied).
See Fig. 1. Loosen the grounding lug locknut (W)
and washer (X). Insert one end of a 1.5 mm@ (12
ga) minimum ground wire (45) into the slot in lug
(Z) and tighten the locknut securely. Connect the
other end of the wire to a true earth ground.
9. To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.
307932
5
Installation
Supplied Components
System Accessories
Refer to Fig. 2 for a typical installation of an airless
system.
Air and Fluid Hoses
Be sure all air hoses (A) and fluid hoses (G) are prop-
erly sized and pressure-rated for your system. Use
only electrically conductive hoses.
WARNING
A red-handled bleed-type master air valve (14) and
a fluid drain valve (7) are supplied in your system.
These accessories help reduce the risk of serious
injury, including fluid injection and splashing of fluid
in the eyes or on the skin, and injury from moving
parts if you are adjusting or repairing the pump.
1. Connect one end of the fluid line (G) to the filter
outlet swivel. Connect a fluid hose to each gun (H).
Install a fluid shutoff valve (J) at each gun drop.
Do not install the spray tip in the gun yet.
The red-handled bleed-type master air valve re-
lieves air trapped between this valve and the pump
after the air is shut off. Trapped air can cause the
pump to cycle unexpectedly. Locate the valve close
to the pump.
2. Close the red-handled bleed valve (14) and air
regulator (8). Connect the air hose (A) to the
swivel inlet of the air manifold (15).
The fluid drain valve assists in relieving fluid pres-
sure in the displacement pump, hose, and gun.
Triggering the gun to relieve pressure may not be
sufficient.
Air Line Accessories
D The red-handled bleed-type master air valve
(14) is required in your system to relieve air trapped
between it and the air motor when the valve is
closed (see the WARNING above). Be sure the
bleed valve is easily accessible from the pump, and
is located downstream from the air regulator.
1. Install an air line filter (B) in the main air line, to
remove harmful dirt and moisture from the com-
pressed air supply.
D The air regulator (8) controls pump speed and
outlet pressure by adjusting the air pressure to the
pump. Locate the regulator close to the pump, but
upstream from the red-handled bleed-type master
air valve (14).
2. Install a second bleed valve (C) in the main air
line, to isolate the accessories for servicing.
3. Install a drain valve (D) at the bottom of each air
D The air manifold (15) has a swivel air inlet. It
mounts to the cart, and provides ports for connect-
ing lines to air-powered accessories.
line drop, to drain off moisture.
D The fluid filter (4) includes a 60 mesh (250 mi-
cron) stainless steel element to filter particles from
the fluid as it leaves the pump.
4. To provide automatic lubrication of the air motor,
install an air line lubricator (E) downstream from
the red-handled bleed-type master air valve (14).
D The fluid drain valve (7) is required in your sys-
tem to relieve fluid pressure in the hose and gun
(see the WARNING above).
5. Install a pump runaway valve (F). The runaway
valve will automatically shut off the air to the pump
if the pump starts running too fast. A pump that
runs too fast can be seriously damaged.
D The suction hose (24) and tube (25) allow the
pump to draw fluid from a 200 liter (55 gallon)
drum.
6
307932
Installation
KEY
SUPPLIED COMPONENTS
ACCESSORIES YOU MUST SUPPLY
1
2
4
7
8
Pump
Pump Wall Bracket
Fluid Filter
Fluid Drain Valve (required)
Pump Air Regulator
A
B
C
D
E
F
Electrically Conductive Air Hose
Air Line Filter
Bleed-Type Master Air Valve (for accessories)
Air Line Drain Valve
Air Line Lubricator
Pump Runaway Valve
14 Red Handled Bleed-Type Master Air Valve (required, for pump)
15 Air Manifold
G
H
J
Electrically Conductive Fluid Line
Airless Spray Gun
Fluid Shutoff Valve
24 Suction Hose
25 Suction Tube
45 Ground Wire (required; see page 5 for installation instructions)
C
B
Model 245187 Shown
45
E
G
J
1
14
A
D
H
H
8
J
2
F
15
4
7
G
G
24
25
01763A
Fig. 2
307932
7
Installation
Models 245187 and 253697 (for Ambient
Temperature Spray Applications)
NOTE: Refer to page 10 to convert Pump Model
245187 or 253697 to a heated system.
1. Mount the pump wall bracket (2) 5 ft (1.5 m) above
the floor. Be sure the wall is strong enough to
support the weight of the pump and accessories,
fluid, hoses, and stress caused during pump
operation. Refer to Mounting Hole Layout on
page 20.
2
2. Connect the air and fluid hoses and the spray gun
as explained on page 6.
4414B
Model 245187 Shown
Fig. 3
8
307932
Installation
4. Use M8 or 5/16 in. bolts of the appropriate length
Models 245185 and 245186 (for Heated
Temperature Spray Applications)
and lockwashers (not supplied) to fasten the
heater brackets to the wall.
1. Be sure the wall is strong enough to support the
weight of the pump and accessories, heaters,
hoses, fluid, and stress caused during operation.
5. Bring the hose (31a) from the inlet elbow (32a) of
the lower heater (44a) and connect it securely to
the swivel (50) coming from the pump outlet. See
Fig. 4.
2. Mount the pump wall bracket (2) 5 ft (1.5 m) above
the floor. Refer to the Mounting Hole Layout on
page 20.
6. Route the hose (31b) from the inlet elbow (32b) of
the upper heater (44b), behind the lower heater
(44a), and connect it securely to the swivel (34a)
at the outlet of the lower heater.
3. Locate the holes for the heater wall brackets (26*)
exactly as indicated on page 20. Use the heater
wall brackets as templates to mark the wall.
7. Bring the fluid supply hose (31) from the swivel
(34b) at the fluid filter (4) outlet and connect it to
the main fluid supply line to the guns.
8. Bring the fluid return hose (37) from the three-way
ball valve (40) and connect it to the main fluid
return line.
NOTE: Refer to the Mounting Hole Layout on page
20. Note that one set of mounting holes is above and
slightly to the left of the other. Install the heater (44)
with the fluid filter (4) attached in that set of holes.
Install the heater without the fluid filter (4) in the lower
set of holes.
9. Connect the air and fluid hoses and the spray gun
as explained on page 6.
1
2
Connect supply hose (31) to the main fluid supply line to the guns.
Connect return hose (37) to the main fluid return line.
31
1
44b
34b
4
32b
34a
32a
31b
2 37
44a
50
40
31a
04419D
Fig. 4
307932
9
Installation
Converting to a Heated System
Installing Dual Heater Mounting Kit 222311
To convert Model 245187 or 253697 to a heated
circulating system, order the following parts. The
heaters are available in three voltages. Specify which
voltage you desire.
WARNING
Before installing the heaters, dual heater mounting
kit and circulating kit, follow the Pressure Relief
Procedure on page 14. Disconnect all hoses from
the pump.
D
T
w
o
V
i
s
c
o
n
H
P
F
l
u
i
d
H
e
a
t
e
r
s
– Model 245848 (120 V, single-phase, 19.2 amp)
– Model 245863 (240 V, single-phase, 16.7 amp)
– Model 245864 (480 V, single-phase, 8.30 amp)
D Dual Heater Mounting Kit 222311
D Circulating Kit 222312
NOTE: Reference numbers marked with an asterisk
(for example, 26*) are included in kit 222311.
D
W
a
r
n
i
n
g
L
a
b
e
l
2
9
0
0
7
4
Apply pipe sealant (36*) to all male threads except at
swivel connections.
WARNING
The Viscon HP Heaters must be installed by a
qualified electrician in compliance with all state and
local codes and regulations, to reduce the risk of
electric shock or other serious injury during installa-
tion or operation.
1. Be sure the wall is strong enough to support the
weight of the heaters, hoses, fluid, and stress
caused during operation. Locate the holes for the
heater wall brackets (26*) exactly as indicated on
page 20. Note that one heater will be mounted
above and slightly to the left of the other. Use the
heater wall brackets as templates to mark the wall.
The power supply must match the heaters’ require-
ments (see above). Refer to the Viscon HP Heater
Manual, 309524, for further information.
Accessories for a Heated System
2. Attach a heater wall bracket to each heater’s
mounting posts with the M8 x 1.25 screws and
lockwashers supplied with the heater (44).
Viscon HP Heater Cord 110160
12 gauge, rated at 105_ C.
WARNING
Do not use in hazardous areas containing flam-
3. Use M8 or 5/16 in. bolts of the appropriate length
and lockwashers (not supplied) to fasten the
heater brackets to the wall.
mable materials or fumes.
Airless Insulated Hose Kit 222263
4. Remove the fluid filter (4) and attaching hardware
(3, 9) from the pump fluid outlet. Keep the filter,
but discard the attaching hardware. See Fig. 5.
25 ft. (7.6 m) nylon fluid hose for use with airless
heated systems. Includes an in-line fluid filter, circulat-
ing manifold, and 3 ft. (0.9 m) whip hose.
10 307932
Installation
5. Screw the 3/4 npt street elbow (28*) into the
9. Screw the bushing (62) and a 3/8 npt nipple (33*)
into the upper heater’s outlet. Screw the fluid filter
(4) inlet onto this nipple. Unscrew the adapter (10)
from the filter outlet. Screw the 1/4 x 3/8 npt nipple
(35*) into the filter outlet, and screw the union (34*)
onto the nipple. See Fig. 6.
pump’s fluid outlet. Assemble the nipple (27*),
check valve (29*), coupling (30*), and swivel (50*)
as shown in Fig. 6. The arrow on the check valve
must point down, toward the coupling.
6. Screw an elbow (32*) onto the lower heater’s inlet.
Screw the coupler (63) onto the elbow. Attach the
heater hose (31*) to the coupler. Connect the other
end of the hose to the swivel (50*) coming from
the pump outlet.
WARNING
7. Screw an elbow (32*) onto the upper heater’s inlet.
Screw the coupler (63) onto the elbow. Attach the
second heater hose (31*) to the coupler. Run this
hose to the left of and behind the lower heater.
See Fig. 4.
COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause compo-
nent rupture and serious injury, never
exceed 90 psi (6 bar, 600 kPa) incoming air pres-
sure to the pump.
8. Install the bushing (62) and a 3/8 npt nipple (33*)
in the lower heater’s outlet. Screw the rigid end of
the union (34*) onto this nipple, and screw the
swivel end of the union onto the free end of the
second heater hose (31*).
10. Install the warning label (51) as shown in Fig. 6.
1
2
24
3
9
10
4
25
11
12
4417B
Fig. 5
307932
11
Installation
4. Install the CIRC end of the three-way ball valve
Installing Circulating Kit 222312
(40{) in the bushing (49{). Screw a bushing (39{)
onto the IN branch of the three-way valve. Con-
nect the rigid end of the 45_ union (38{) to this
bushing. Screw the swivel end of the union (38{)
onto the braided hose (37{). Connect this hose to
the main fluid return line. See Fig. 6.
WARNING
Before installing the heaters, dual heater mounting
kit and circulating kit, follow the Pressure Relief
Procedure on page 14. Disconnect all hoses from
the pump.
5. Screw another bushing (39{) onto the DRAIN end
of the three-way valve (40{). Connect the nylon
fluid hose (41{) to this bushing, and connect the
return tube (42{) to the other end of the hose.
Place the return tube in the fluid supply container.
NOTE: Reference numbers marked with a symbol (for
example, 37{) are included in kit 222312.
Apply pipe sealant (36{) to all male threads except at
swivel connections.
WARNING
1. Remove the suction tube (25), fittings (52 and 53),
hose (24), and adapter (12). See Fig. 5. Keep
these parts for use later.
COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause compo-
nent rupture and serious injury, never
exceed 90 psi (6 bar, 600 kPa) incoming air pres-
sure to the pump.
2. Screw nipple (54) and then the tee (48{) into the
elbow (11) at the pump fluid inlet. Screw the 1 x
3/4 npt bushing (55) and then the 3/4 npt x 1/4 npt
bushing (49{) into the branch of the tee. See Fig.
6.
6. Install the warning label (51) as shown in Fig. 6.
3. Reconnect the bushing (12), hose (24), fittings (52
and 53), and suction tube (25).
7. Connect the air and fluid hoses and the spray gun
as explained on page 6.
12 307932
Installation
1
2
3
4
Specify desired heater voltage (see page 10).
Part of the heater (44).
Connect to the main fluid supply line to the guns.
4
5
31
34*
5
Connect to the main fluid return line.
44
64*
1
Arrow must point down.
1
35*
4
6
44
1
26*
51
33*
33*
62
62
7
2
20
45
34*
64*
A
A
32*
*31
31*
(Ref)
C
C
21
22
2
32*
28*
27*
31*
(Ref)
B
47
22
11
54
37{
3
5
29*
38{
39{
30*
64*
48{
12
31*
24
B
55
40{
41{ 39
{
49{
42{
52
53
25
5365D
Fig. 6
307932
13
Operation/Maintenance
Pressure Relief Procedure
Packing Nut/Wet-Cup
Before starting, fill the packing nut (U) 1/3 full with
Graco Throat Seal Liquid (TSL) or compatible solvent.
See Fig. 7.
WARNING
SKIN INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure at left.
starting or spraying accidentally. Fluid
under high pressure can be injected through the
skin and cause serious injury. To reduce the risk of
an injury from injection, splashing fluid, or moving
parts, follow the Pressure Relief Procedure
whenever you:
The packing nut is torqued at the factory and is ready
for operation. If it becomes loose and there is leaking
from the throat packings, relieve pressure, then tighten
the nut as specified in your separate pump manual. Do
this whenever necessary. Do not overtighten the
packing nut.
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray tips.
1. Lock the gun trigger safety.
Flush the Pump Before First Use
2. Shut off the air supply to the pump.
Pumps are tested with lightweight oil which is left in to
protect the pump parts. To prevent contamination of
the fluid, flush the pump with a compatible solvent
before using it.
3. Close the bleed-type master air valve (required in
your system).
4. Unlock the gun trigger safety.
5. Hold a metal part of the gun firmly to the side of a
grounded metal pail, and trigger the gun to relieve
pressure.
6. Lock the gun trigger safety.
7. Open the drain valve (required in your system),
having a container ready to catch the drainage.
8. Leave the drain valve open until you are ready to
spray again.
If you suspect that the spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following the steps above, very slowly loosen the
tip guard retaining nut or hose end coupling and relieve
pressure gradually, then loosen completely. Now clear
the tip or hose.
Model 254187 Shown
U
4414B
Fig. 7
14 307932
Operation/Maintenance
9. Use the air regulator to control the pump speed
Starting and Adjusting the Pump
and fluid pressure. Always use the lowest pressure
necessary to achieve the desired results. Higher
pressures waste fluid and cause premature wear
of the pump packings and spray tip.
1. Be sure the air regulator and bleed-type master air
valve are closed.
NOTE: Do not install the spray tip yet!
2. Open the bleed-type master air valve.
CAUTION
3. Hold a metal part of the spray gun firmly to the
side of a grounded metal pail and trigger the gun.
Do not allow the pump to run dry. It will quickly
accelerate to a high speed, causing damage. If your
pump is running too fast, stop it immediately and
check the fluid supply. If the container is empty and
air has been pumped into the lines, refill the con-
tainer and prime the pump and the lines, or flush and
leave it filled with a compatible solvent. Eliminate all
air from the fluid system.
4. Slowly open the air regulator until the pump starts.
5. Allow the pump to cycle slowly until all the air is
pushed out of the fluid lines.
6. Release the gun trigger and lock the trigger safety;
the pump will stall against the pressure.
Heated Circulating Systems
7. With the pump and lines primed, and with ade-
quate air pressure and volume supplied, the pump
will start and stop as the spray gun is triggered and
released.
Operating instructions for a heated circulating system
are provided in the Viscon HP Heater manual,
309524. Read and understand all warnings and in-
structions in the heater manual before operating a
heated system.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 14.
1. The three-way ball valve (40) selects either fluid
circulation or draining. To circulate fluid back to the
pump, turn the handle toward the CIRC end of the
valve.
8. Relieve the pressure, then install the spray tip in
the gun.
2. To drain the fluid, turn the handle toward the
DRAIN end.
307932
15
Operation/Maintenance
Shutdown and Care of the Pump
CAUTION
Never leave water or water-base fluid in the pump
overnight. If you are pumping water-base fluid, flush
with water first, then with a rust inhibitor such as
mineral spirits. Relieve the pressure, but leave the
rust inhibitor in the pump to protect the parts from
corrosion.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 14.
For overnight shutdown, stop the pump at the bottom
of its stroke to prevent fluid from drying on the ex-
posed displacement rod and damaging the throat
packings. Relieve the pressure.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 14.
Always flush the pump before the fluid dries on the
displacement rod. See Flushing below.
Flushing
1. Relieve the pressure.
WARNING
2. Remove the spray tip from the gun.
FIRE AND EXPLOSION HAZARD
Before flushing, read the section FIRE
OR EXPLOSION HAZARD on page 4.
Be sure the entire system and flushing
pails are properly grounded. Refer to
Grounding on page 5.
3. Hold a metal part of the gun firmly to the side of a
grounded metal pail.
4. Start the pump. Always use the lowest possible
fluid pressure when flushing.
5. Trigger the gun.
Flush with a fluid that is compatible with the fluid you
are pumping and with the wetted parts in your system.
Check with your fluid manufacturer or supplier for
recommended flushing fluids and flushing frequency.
Always flush the pump before fluid dries on the dis-
placement rod.
6. Flush the system until clear solvent flows from the
gun.
7. Relieve the pressure.
16 307932
Parts
Model 245187, 33:1, Series B
Model 253697, 28:1, Series A
Ref
Ref
No.
Part No.
Description
Qty
No.
Part No.
Description
Qty
1
245117
33:1 BULLDOG PUMP (245187 only)
See 309340 for parts
28:1 BULLDOG PUMP (253697 only)
See 309340 for parts
BRACKET, wall, pump
NIPPLE, reducing; 3/4 npt x 3/8 npsm 1
FLUID FILTER
20
100101
SCREW, cap, hex hd;
3/8–16 x 1 in. (25 mm) long
WASHER, spring lock; 3/8 in.
NUT, hex; 3/8–16
HOSE, siphon; nylon; 1 in. npt;
6 ft (1.8 m) long
SUCTION TUBE; 3/4 npt(f)
THROAT SEAL LIQUID
8 oz (0.5 liters); not shown
GROUND WIRE
WASHER, lock; 3/8 in.
COUPLING, pipe
1
4
4
5
245167
21
22
24
100133
100131
244516
1
1
2
3
4
206294
161800
218029
1
1
25
43
206266
206994
See 307273 for parts
1
4
1
5
6
7
100509
150286
210658
PLUG, pipe, sq hd; 1/4 npt
ADAPTER; 3/8 npt (m x f)
DRAIN VALVE; 3/8 npt(mbe)
See 306861 for parts
AIR REGULATOR
See 308168 for parts
UNION, adapter, straight; 3/8 npt(m) x
3/8 npsm(f) swivel
ADAPTER, 1/4 npt(m) x
3/8 npsm(f) swivel
1
1
2
1
1
1
45
47
52
53
54
237569
100322
100474
158555
158586
1
1
1
1
8
206197
155665
157705
116401
116402
113269
NIPPLE, reducing; 1 npt x 3/4 npt
BUSHING, 1 x 3/4
9
45
10
11
12
14
ELBOW, street, 90_; (f) 1 11–1/2 x 1–1/4
11–1/2(f); zinc-plated malleable iron
ADAPTER; (f) 1 11–1/2 x 1–1/4
11–1/2(f); zinc–plated malleable iron
BLEED VALVE, red-handled;
1/2 npt (m x f)
MANIFOLD, air; 3/4 npsm(f)
GAUGE, air
ELBOW, street; 90_; 1/4 npt (m x f)
PLUG, pipe; 1/8 npt
1
1
1
1
1
1
1
1
A
20
15
16
17
18
19
206205
100960
100840
100403
214952
A
4
HOSE, air; 3/4 in. (19 mm) ID;
3/4 npt(m) x 1/2 npt(m);
16 in. (406 mm) long
1
21
22
AIR REGULATOR DETAIL
2
19
4
See Detail at left.
54
3
9
5
10
5
47
22
14
16
17
8
52
53
5
15
4
6
25
11
18
12
7
05364
24
307932
17
Parts
Model 245185, Series A (240 Volt Heater)
Model 245186, Series A (480 Volt Heater)
Ref
No.
Ref
No.
Part No.
Description
Qty
Part No.
159801
165198
Description
Qty
1
245117
33:1 BULLDOG PUMP
See 309340 for parts
BRACKET, wall, pump
FLUID FILTER
34*
35*
UNION, adapter, 90_;
3/8 npt(f) x 1/2 npsm(f) swivel
NIPPLE, reducing; 1/4 npt(m) x
3/8 npt(m)
1
1
2
1
2
4
206294
218029
See 307273 for parts
PLUG, pipe, sq hd; 1/4 npt
ADAPTER; 3/8 npt (m x f)
DRAIN VALVE; 3/8 npt(mbe)
See 306861 for parts
AIR REGULATOR
1
4
1
36*
{
110110
207296
SEALANT, pipe; sst; 6 ml (not shown) 1
HOSE, fluid; PTFE tube
w/braid cover; 13/32 in. ID;
5
6
7
100509
150286
210658
37
{
cpld 3/8 npt (mbe); 31 in. (0.8 m) long
UNION, adapter, 45_;
3/8 npt(f) x 3/8 npsm(f) swivel
1
1
1
1
38
{
207411
8
206197
116401
116402
113269
See 308168 for parts
ELBOW, street, 90_; (f) 1 11–1/2 x 1–1/4
39
40
{
{
100176
214711
BUSHING, hex; 1/4 npt(f) x 3/8 npt(m) 2
BALL VALVE, three-way; 1/4 npt(m);
11
12
14
11–1/2(f); zinc-plated malleable iron
ADAPTER; (f) 1 11–1/2 x 1–1/4
11–1/2(f); zinc–plated malleable iron
BLEED VALVE, red-handled;
1/2 npt (m x f)
1
See 306861 for parts
1
41
{
{
205169
HOSE, fluid; nylon; 3/8 in. ID;
3/8 npsm (fbe); 3 ft (0.9 m) long
TUBE, return; 3/8 npt(m)
THROAT SEAL LIQUID
8 oz (0.5 liters); not shown
VISCON HP HEATER, 240 Volt;
used on Model 245185
see manual 309524
1
1
1
42
43
167905
206994
1
1
1
1
1
15
16
17
18
19
206205
100960
100840
100403
214952
MANIFOLD, air; 3/4 npsm(f)
GAUGE, air
1
44
245863
ELBOW, street; 90_; 1/4 npt (m x f)
PLUG, pipe; 1/8 npt
HOSE, air; 3/4 in. (19 mm) ID;
3/4 npt(m) x 1/2 npt(m);
16 in. (406 mm) long
SCREW, cap, hex hd;
3/8–16 x 1 in. (25 mm) long
WASHER, spring lock; 3/8 in.
NUT, hex; 3/8–16
HOSE, siphon; nylon; 1 in. npt;
6 ft (1.8 m) long
SUCTION TUBE; 3/4 npt(f)
BRACKET, wall, heater
NIPPLE; 3/4 npt
ELBOW, street, 3/4 npt(m x f)
CHECK VALVE; 3/4 npt(m) x 3/4 npt(f);
includes items 29a–29e
. SEAT, valve
. O-RING; fluoroelastomer
. BALL
. GUIDE, ball
2
245864
VISCON HP HEATER, 480 Volt;
used on Model 245186
see manual 309524
GROUNDING WIRE AND CLAMP
WASHER, lock; 3/8 in.
TEE; 1 in. female
BUSHING; 3/4 npt(m) x 1/4 npt(f)
LABEL, warning
COUPLING, pipe
NIPPLE, reducing; 1 npt x 3/4 npt
FITTING, nipple
BUSHING; 1 npt(m) x 3/4 npt(f)
BUSHING, reducer, pipe
NIPPLE, 1/2 npt
1
2
1
2
1
1
1
1
1
1
1
2
3
20
100101
45
47
48
49
51
52
53
54
55
62
237569
100322
500566
100615
290074
100474
158555
158585
158586
502265
158491
4
4
5
21
22
24
100133
100131
244516
{
{
Y
1
1
2
1
1
25
206266
183982
175013
166590
235132
26*
27*
28*
29*
{
{
64*
1
1
1
1
3
1
29a
29b
29c
29d
29e
30*
235133
111691
101190
181492
187861
158556
*
Included in Dual Heater Mounting Kit 222311. Required to
convert Model 245187 or 253697 Sprayers to a heated
unit. The heaters are not included in this kit and must be
ordered separately, by desired voltage (see page 10).
. HOUSING, valve
COUPLING, hex pipe;
1/2 npt(f) x 3/4 npt(f)
HOSE, fluid; nylon; 1/2 in. (12.7 mm) ID;
{
Included in Circulating Kit 222312. Required to convert
Model 245187 or 253697 Sprayers to a circulating unit.
1
31*
H55003
1/2 npt (fbe); 3 ft (0.9 m) long
ELBOW, 90_; 1/2 npt (m x f)
NIPPLE; 3/8 npt
3
2
2
32*
33*
158683
156849
Y
R
e
p
l
a
c
e
m
e
n
t
D
a
n
g
e
r
a
n
d
W
a
r
n
i
n
g
l
a
b
e
l
s
,
t
a
g
s
a
n
d
c
a
r
d
s
are available at no cost.
18 307932
Parts
Model 245185, Series A (240 Volt Heater)
Model 245186, Series A (480 Volt Heater)
4
5
31
34*
1
2
3
4
5
6
Specify desired heater voltage (see page 10).
Part of the heater (44).
Connect to the main fluid supply line to the guns.
Connect to the main fluid return line.
44
64*
1
See Check Valve Detail.
1
See Air Regulator Detail.
35*
4
6
44
1
26*
51
33*
33*
62
62
7
2
45
20
34*
64*
A
A
32*
*31
31*
(Ref)
C
C
21
22
2
32*
28*
27*
31*
(Ref)
B
47
22
11
54
37{
3
5
29*
38{
39{
30*
64*
48{
12
31*
24
B
AIR REGULATOR DETAIL
55
40{
41{ 39
{
49{
19
14
CHECK VALVE DETAIL
29a
42{
52
53
16
29b
29c
17
8
29d
29e
25
5
15
18
5365D
Fig. 8
307932
19
Mounting Hole Layout
M8 or 5/16 in. diameter holes for
heater wall brackets (or use brackets
as templates to mark wall).
6 in.
(152 mm)
12.375 in.
(314 mm)
15 in.
(381 mm)
5 in.
(127 mm)
7.375 in.
(187 mm)
8.5 in.
(216 mm)
6 in.
(152 mm)
7/16 in. diameter holes for pump wall
bracket (mount 5 ft [1.5 m] above floor;
refer to 306783 for instructions).
20 307932
Technical Data
Category
Data
Maximum fluid working pressure
Model 245187: 3300 psi (228 bar, 22.8 MPa)
Models 245185, 245186: 3000 psi (207 bar, 20.7 MPa)
Model 253697: 2800 psi (193 bar, 19.3 MPa)
Maximum air input pressure
Ratio
Models 245187, 253697: 100 psi (7 bar, 700 kPa)
Model 245185, 245186: 90 psi (6 bar, 600 kPa)
Models 245185, 245186, 245187: 33:1
Model 253697: 28:1
Pump performance data
Air consumption data
See pump manual 309340
See pump manual 309340
Maximum operating temperature
Models 245187, 253697 (ambient temperature applications): 180_ F (82_ C)
Models 245185, 245186 (heated applications): 205_ F (93_ C)
Air inlet size
3/4 npsm(f)
3/8 npsm(f)
1–1/2 in. npt(f)
Fluid outlet size (at fluid filter)
Fluid inlet size
Weight
Models 245187, 253697: 135 lb (61 kg)
Models 245185, 245186: 210 lb (95 kg)
Wetted parts
Pump: See pump manual 309340
Fluid Filter: See manual 307273
Heater: See manual 309524
Suction Hose and Tube: LDPE, Carbon Steel
Fluid Fittings: Carbon Steel, Wrought Steel/Plated, Malleable Iron/Plated
Sound Pressure Levels
(tested at 1 meter from motor)
Input Air Pressures at 15 cycles per minute
40 psi
70 psi
90 psi
100 psi
(7 bar, 700 kPa)
Air Motor
(2.8 bar, 280 kPa) (4.8 bar, 480 kPa) (6 bar, 600 kPa)
Standard Bulldog
82.4 dB(A)
87.3 dB(A)
88.5 dB(A)
90.0 dB(A)
Sound Power Levels
(tested in accordance with ISO 9614)
Input Air Pressures at 15 cycles per minute
40 psi
70 psi
90 psi
100 psi
(7 bar, 700 kPa)
Air Motor
(2.8 bar, 280 kPa) (4.8 bar, 480 kPa) (6 bar, 600 kPa)
Standard Bulldog
91.6 dB(A) 95.9 dB(A) 97.4 dB(A)
98.1 dB(A)
307932
21
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–328–0211 Toll Free
612–623–6921
612–378–3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
MM 307932
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
307932 12/1988, Revised 06/2006
22 307932
|