HP Hewlett Packard Network Router SR2122 2 User Manual

Release Notes  
hp StorageWorks  
SR2122-2 IP Storage Router  
Product Version: 3.4.5b  
Fourth Edition (March 2005)  
Part Number: AA-RV20C-TE  
These release notes are for the HP StorageWorks SR2122-2 IP Storage Router running firmware version 3.4.5b  
and provides important information not covered in other documentation.  
For the latest version of these Release Notes and other IP storage router documentation, access the HP storage  
.
 
About this document  
About this document  
This section describes the content reflected in this document, including:  
Release notes information  
These Release Notes cover the following major topics:  
Intended audience  
This document is intended for customers who purchased the SR2122-2 IP Storage Router.  
Other SR2122-2 IP Storage Router documentation  
The SR2122-2 IP Storage Router kit also includes:  
HP StorageWorks SR2122-2 IP Storage Router User Guide  
HP StorageWorks SR2122-2 IP Storage Router Command Line Interface Reference Guide  
HP StorageWorks SR2122-2 IP Storage Router Rack Mount Template  
HP StorageWorks SR2122-2 IP Storage Router Getting Started Guide (web only)  
HP StorageWorks SR2122-2 IP Storage Router Product Support Tables (web only)  
Additional documentation, including white papers and best practices documents, are available  
via the HP web site at: http://www.hp.com  
.
SR2122-2 IP Storage Router Release Notes  
3
 
     
Overview  
Overview  
These release notes are for the HP Storageworks SR2122-2 IP Storage Router running  
firmware version 3.4.5b. This document provides important information that is not covered in  
other documentation.  
Important: Read this entire document before installing and configuring the HP  
Storageworks SR2122-2 IP Storage Router.  
4
SR2122-2 IP Storage Router Release Notes  
 
 
Identifying the SR2122-2 Version Level  
Identifying the SR2122-2 Version Level  
You can determine the SR2122-2 software version level by typing the following command at the  
SR2122-2 CLI prompt:  
[SR2122-2]# sho version  
The resulting display lists the software version level:  
Hewlett-Packard SR2122 Storage Router  
CLI Version: 2.1  
iSCSI Version: 0/2 (Min/Max)  
System Bootstrap: 3.4.5b-K9  
Operating System: 3.4.5b-K9  
Application: 3.4.5b-K9  
Web Server: R6_1_0  
OpenSSH: 3.4p1  
OpenSSL: 0.9.6e  
Zlib: 1.1.4  
Copyright (c) 1994-2003 Hewlett-Packard Company  
[SR2122-2]#  
SR2122-2 IP Storage Router Release Notes  
5
 
 
Identifying the HP-UX iSCSI Software Initiator version  
Identifying the HP-UX iSCSI Software Initiator version  
To identify the HP-UX iSCSI Software Initiator driver version, enter the following command  
while logged in as root or superuser.  
root-> /usr/sbin/swlist iSCSI-00  
Identifying the HP Windows iSCSI driver version level  
Open the “hp iSCSI Config” application found in the Windows Control Panel.  
Figure 1: iSCSI Driver Version  
The Windows iSCSI driver version (3.1.4) will appear in the lower left-hand corner.  
6
SR2122-2 IP Storage Router Release Notes  
 
   
Identifying the Linux Red Hat iSCSI driver version level  
Identifying the Linux Red Hat iSCSI driver version level  
To verify the iSCSI driver on a Linux Red Hat host, type the following command:  
cat /proc/scsi/iscsi/0 | grep "iSCSI driver Version"  
The resulting display lists the software version level:  
iSCSI driver version: 3.4.1 (20-Oct-2002)  
SR2122-2 software and iSCSI driver updates  
To view the latest version of SR2122-2 software or Windows iSCSI drivers please see the  
SR2122-2 web site:  
For the HP-UX iSCSI Software Initiator, supporting patches and other driver related  
information are maintained in Release Notes. To access the Release Notes:  
1. Go to the URL: www.docs.hp.com  
2. Click on "Networking and Communications"  
3. Click on "iSCSI (SCSI over TCP/IP)"  
4. Click on the Release Note link for the appropriate version of HP-UX  
To download the HP-UX iSCSI Software Initiator:  
1. Go to the URL: www.software.hp.com  
2. Click on HP-UX 11i operating environment  
3. Click on "iSCSI Software Initiator"  
To view the latest Linux drivers for the HP SR2122-2 iSCSI router please refer to the  
following web site:  
For Microsoft’s iSCSI initiator driver, refer to the Microsoft website.  
SR2122-2 IP Storage Router Release Notes  
7
 
   
Hardware and software support  
Hardware and software support  
Refer to the SR2122-2 IP Storage Router Product Support Tables for the latest hardware and  
software support information. The Tables are available at:  
Network interface controller (NIC) hardware support  
The following Network Interface Controllers are supported:  
HP-UX - All NICs supported by HP-UX  
Microsoft Windows - All GbE NICS supported by HP for Windows  
Red Hat Linux - All GbE NICS supported by HP for Red Hat Linux  
Operating system software support  
The following operating system software versions are supported with the SR2122-2 with  
iSCSI:  
HP-UX 11i v1, HP-UX 11i v2  
Microsoft Windows 2000 SP2 with either Microsoft hotfix Q302895 or Q248720 and  
Microsoft hotfix Q318271, SP3  
Red Hat Advanced Server 2.1  
Windows 2003  
Refer to the HP StorageWorks SR2122-2 IP Storage Router Product Support Tables for  
supported operating system software versions with the SR2122-2 and FCIP. This document is  
available at:  
Compaq Network Teaming software support  
Compaq Network Teaming is supported on the Windows operating system.  
SR2122-2 management software support  
The following HP management software is supported:  
Compaq Insite Manager 7  
HP Openview Storage Manager  
The SR2122-2 management software is supported on Windows and Linux operating systems  
only.  
8
SR2122-2 IP Storage Router Release Notes  
 
 
SR2122-2 configuration rules  
SR2122-2 configuration rules  
SR2122-2 router rules  
Table 1: SR2122-2 Router Rules  
Router Rule  
Maximum  
Maximum scsirouter instances per SR2122-2 Router  
(and per SR2122-2 Router Cluster)  
12  
Maximum iSCSI host connections per  
SR2122-2 SCSI Router instance  
32  
Maximum active logical units (LUNs) per SR2122-2 Router  
Maximum active targets per SR2212-2 Router  
120  
120  
nd  
The SR2122’s 2 fibre Channel port (FC2) is not supported as a redundant SAN port for  
FC1.  
Direct connect of the SR2122-2 Fibre Channel ports to any HP storage array is not  
supported.  
The MSR2122 Management port must be in a different subnet than the SCSI Router  
Instances.  
iSCSI host rules  
Table 2: ISCSI Host Rules  
iSCSI Host Rule  
Operating System  
Maximum  
Maximum targets accessed per iSCSI host  
Windows 2000,  
120  
Windows 2003, HP-UX, Linux  
Maximum active LUNs per target  
Windows 2000,  
120  
Windows 2003, Linux, HP-UX  
Operation system rules  
Linux Clustering is not supported.  
HP Secure Path for Linux with the MSA1000, RA/MA8000, EMA/ESA12000 and  
Enterprise Virtual Arrays is not supported.  
HP Auto Path for VA/XP for HP-UX, Windows 2000, Windows 2003 and Linux are not  
supported.  
HP Secure Manager on XP and VA is not supported.  
The MSA1000 is not supported with Secure Path for Windows  
SR2122-2 IP Storage Router Release Notes  
9
 
 
SR2122-2 configuration rules  
Storage array rules  
Without HP Secure Path the Enterprise Virtual Array is supported with the SR2122-2  
accessing only one EVA controller port. This will disable controller failover protection.  
The SR2122-2 fibre channel ports appear as host bus adapters to the Fibre Channel  
switches and to all storage arrays.  
Fibre Channel switch/fabric rules  
The SR2122-2 should only be zoned with the storage devices that it will access. Zoning  
the SR2122-2 with other servers is not supported.  
Disable useBportwhen connecting the SR2122-2 to C-series switches using MDS  
switch firmware v2.01b or later.  
Disable useBportwhen connecting the SR2122-2 to B-series switches running switch  
firmware 3.2.x or 4.4.x or later. Enable useBportfor switches running other firmware  
versions.  
Management software rules  
OVSAM support is limited to property support only. It will identify the device, and by  
clicking on it, one can launch the device embedded web server interface or telnet. A device  
specific plug-in for the SR2122-2 is available on the OVSAM Website.  
CIM 7 Supports the SR2122’s SNMP management capabilities.  
Management of the storage arrays through the SR2122-2 is not supported. Please use the  
recommended application/element manager to configure the storage array.  
Updates/Fixes for this release of firmware  
Fixes include:  
Memory (mbuf) leak during handling of Async event (RX_LR) during handling of FCIP  
link failure.  
A memory leak and potential router crash would occur because of a mishandling of a link  
failure during an unstable FCIP connection. This problem would never appear during  
normal FCIP operations and is fixed in this release.  
An SR2122-2 would “panic” when a standard MIB II polling engine, such as the HP  
OpenView Network Node Manager, attempted to SNMP poll the SR2122-2.  
10  
SR2122-2 IP Storage Router Release Notes  
 
Known problems  
Known problems  
C-series MDS v2.01b switch firmware requirements  
For iSCSI with C-Series switches, the Fibre Channel port on the C-series switch that  
connects to the SR2122-2 must be set to FL-Port mode if using MDS v2.01b or later  
switch firmware.  
For FCIP with C-Series switches, the SR2122-2 must be configured for useBport  
disabled if using MDS v2.01b or later switch FW. Refer to page 62 of the  
HP StorageWorks SR2122-2 IP Storage Router Getting Started Guide for more  
information.  
ISL loss can result when the SR2122-2 is configured as FCIP and used to extend  
B-series switches upgraded to firmware 3.2.x or 4.4.x  
When the SR2122-2 is used to extend a fabric between two B-series switches, the ISL may  
segment due to a switch firmware upgrade. The new firmware is now aware of SAN extension  
gateways such as the SR2122-2 and can now enable ISL R_RDY mode on a port.  
ISL R_RDY mode sends ELP with Flow Control Mode 02 and enables connectivity with  
WAN gateway products. If a port is ISL R_RDY mode-enabled, it can only receive ELP with  
Flow Control Mode 02; ELP with Flow Control Mode 01 segments the fabric.  
This mode cannot detect the PID format of connected ports. If the PID formats for two ISL  
R_RDY mode ports are not the same, zoning drops frames.  
This feature is persistent across reboots and does not require a license key.  
Use the portCfgShowcommand to view whether ISL R_RDY mode is enabled on a port.  
The switch ports now connected to the Fibre Channel ports of the SR2122-2 must have ISL  
R_RDY mode enabled. This is accomplished with the following switch CLI command:  
portcfgislmode[slotnumber/]portnumber, [mode]  
slotnumber - Specify the slot number for a B-Series director. For all other switches, this  
operand is not required. The slot number must be followed by a slash ( / ) and the port  
number, so that each port is represented by both slot number (1 through 4 or 7 through 10)  
and port number (0 through 15).  
The B-series Director has a total of 10 slots. Slot numbers 5 and 6 are control processor  
cards; slots 1 through 4 and 7 through 10 are port cards. On each port card, there are 16  
ports, counted from the bottom, numbered 0 to 15.  
portnumber - Specify a port number. Valid values for port number vary, depending on  
the switch type. This operand is required.  
mode - Specify 1 to enable ISL R_RDY mode. Specify 0 to disable ISL R_RDY mode.  
This operand is required.  
RA/MA8000, ESA/EMA12000 LUNs are initially passed to the SR2122-2 with the  
offset included in the LUN numbering.  
When LUNs are first presented to the SR2122-2 from an RA/MA8000, ESA/EMA12000 a  
“Show Devices” issued on the SR2122-2 may show the LUNs with the offset number  
included.  
SR2122-2 IP Storage Router Release Notes  
11  
 
 
Known problems  
For example, if the offset for the SR2122-2 connection is 80 and LUNs 81 and 82 are  
presented to the SR2122-2 then they may appear on the SR2122-2 as LUN 81 and 82 for the  
controller.  
A reboot of the SR2122-2 will set them correctly to LUN 1 and LUN 2.  
Ports FC1 and FC2 are set to Loop Preferred by default  
During the initial setup of the SR2122-2, the user is asked to specify whether the Fibre  
Channel ports are connected to an Fibre Channel hub or Fibre Channel switch. Although  
switch is the only supported option, the Fibre Channel ports are set to Loop Preferred.  
To reset the Fibre Channel ports to the correct setting, Point-to-Point, the user may use the  
Configuration Tab in the SR2122-2 GUI or the SR2122-2 CLI command:  
SR2122> Interface FC1 Topology ptp  
iSCSI CRC support  
The iSCSI CRC feature is not supported with Windows 2000, Windows 2003, and Red Hat  
Linux.  
The iSCSI CRC feature is supported for HP-UX.  
12  
SR2122-2 IP Storage Router Release Notes  
 

Grizzly Automobile Parts H8097 User Manual
Grizzly Outdoor Fireplace GMFP20 User Manual
GTO Safety Gate 10 User Manual
Harbor Freight Tools Router 93787 User Manual
Heartland Stove The Artisan User Manual
HP Hewlett Packard PDAs Smartphones h1910 User Manual
HP Hewlett Packard Work Light 10430A User Manual
Husky Flooring 16628 User Manual
Husqvarna Chainsaw 115 13 82 49 User Manual
Hypertec Mouse KYB500 K82AHY User Manual