Hotpoint Ventilation Hood HD 93 X User Manual

Instructions for use  
HOOD  
Contents  
GB  
GB  
Installation, 10-11  
Assembly  
English  
Technical information, 12  
Electrical connection  
Power cable  
Technical data  
Description, 13  
Filtering version  
Ducting version  
Operation, 14  
Controls  
HD 63 X  
HD 73 X  
HD 93 X  
Maintenance,15  
Cleaning the hood  
Cleaning the grease filters  
Replacing the charcoal filter  
Replacing the lamps  
Precautions and tips, 16  
General safety  
Air vent  
Disposal  
1
 
GB  
d) Make the electrical connection of the hood by  
means of the power cable (refer to the paragraph  
“Electrical connection”).  
3) Ducting version:  
e) Lower the lower flue resting it on the hood.  
f) Check if the charcoal filter (P) has been  
installed. If not yet installed, proceed by sliding  
the 2 filter clips into their seats and turn the  
filter upwards.  
a) Connect the air vent of the hood to the air vent  
hole using a flexible hose of 15 cm diameter.  
Lock the flexible hose with hose clamps (hose  
and clamps not provided).  
b) Make the electrical connection of the hood by  
means of the power cable (refer to the paragraph  
“Electrical connection”).  
c) Fit the decorative flue resting it on the hood. Lift  
the upper flue up to the ceiling and secure it by  
means of the 2 screws (L).  
4) Filtering version:  
a) Fit the baffle (M) to the upper flue using 4 flat-  
headed screws (N). Connect a flexible hose of  
12.5 cm diameter to the baffle locking it with a  
hose clamp (hose and clamp not provided).  
b) Take the decorative flue and rest it on the hood.  
Lift the upper flue up to the ceilingand secure it  
using the 2 screws (L).  
c) Lift the lower flue holding it firm with some  
adhesive tape and connect the flexible hose to  
the reducer (E) with a hose clamp (not provided).  
3
 
Technical information  
which is marked with the letter N or coloured black;  
– the wire which is coloured brown must be  
connected to the terminal which is marked with the  
letter L or coloured red.  
– the wire which is coloured green and yellow  
must be connected to the terminal in the plug  
which is marked with the letter E or by the earth  
Electrical connection  
GB  
!
!
Arrange the electrical power supply within the  
decorative flue dimensions.  
When making the electrical connections, check that  
the voltage values correspond to those indicated on  
the data plate inside the appliance itself.  
symbol [  
and yellow.  
], or coloured green or green  
!
In case your appliance is not furnished with a non  
separating flexible cable and has no plug, or has not  
got any other device ensuring omnipolar  
disconnection from the electricity main, with a  
contact opening distance of at least 3 mm, such  
separating device ensuring disconnection from the  
main must be included in the fixed installation.  
If your unit features a power lead and plug, position  
this so the plug is accessible.  
The following warning is valid in the United Kingdom  
only (in case your cable is not furnished with a  
plug). As the colours of the wires in the mains lead  
of this appliance may not correspond with the  
coloured markings identifying the terminals in your  
plug, proceed as follows: – the wire which is  
coloured blue must be connected to the terminal  
Power cable  
!
Warning: The hood is fitted with a specially  
prepared cable; if the cable is damaged, it must  
be replaced with a cable or special cable  
assembly, available at the manufacturer or its  
technical service.  
!
!
Technical data  
Model  
HD63X  
HD73X  
width 69.8 cm  
HD93X  
Dimensions  
width 59.8 cm  
width 89.8 cm  
height 67.7 / 99.5 cm  
depth 50 cm  
height 67.7 / 99.5 cm  
depth 50 cm  
height 67.7 / 99.5 cm  
depth 50 cm  
Outlet pipe diameter 15 cm  
Outlet pipe diameter 15 cm  
Outlet pipe diameter 15 cm  
Gross weight  
Absorption  
20 Kg  
21 Kg  
24 Kg  
Total 220 W  
Total 220 W  
Total 220 W  
Motor 1x180 W  
Lamps 2x20 W  
Motor 1x180 W  
Lamps 2x20 W  
Motor 1x180 W  
Lamps 2x20 W  
Flow rate  
560 m3/h  
560 m3/h  
944 cm2  
560 m3/h  
944 cm2  
Grease filters  
Suction  
surface area  
944 cm2  
4
 
Description  
The hood may be in the filtering or ducting version.  
Decide from the outset which type is to be installed.  
For better efficiency, we recommend installing the  
hood in the ducting version (if possible).  
Ducting version  
GB  
The hood aspirates air from the kitchen impregnated  
with fumes and smells, passes it through the grease  
filters and then expels it to the outside through an  
exhaust duct.  
Filtering version  
For this version the charcoal filter does not need to be  
used.  
The hood aspirates air from the kitchen impregnated  
with fumes and smells, purifies it through the grease  
filters and the charcoal filter, and then circulates clean  
air back into the room.  
This version requires an air baffle (M) and a charcoal  
filter (P).  
In order to maintain constant efficiency, the charcoal  
filter must periodically be replaced.  
If the hood is not fitted with the charcoal filter,  
request one from the dealer.  
M
P
5
 
Operation  
Controls  
GB  
MOTOR  
LIGHTING  
DECREASE  
INCREASE  
BOOST SPEED  
Light button  
Speed increase button  
Turns the lights on/off.  
Repeatedly pressing the button will increase the motor  
speed until reaching the maximum speed.  
Motor button  
Activates/deactivates the motor.  
Boost speed button  
The motor is activated at the last speed set.  
Activates the motor at boost speed for 10 minutes,  
after which the motor goes back to running at the  
speed set previously.  
Speed decrease button  
Repeatedly pressing the button will reduce the motor  
speed until reaching the minimum speed.  
6
 
Maintenance  
!
!
Always switch off the electricity supply before  
carrying out any cleaning or servicing operations on  
the appliance.  
To avoid possible risks of fire always comply with  
the indicated instructions when cleaning grease  
filters and when removing grease deposits from the  
appliance.  
Replacing the charcoal filter  
GB  
If using the hood in the filtering version, the charcoal  
filter (P) will periodically have to be replaced.  
First of all, remove the metal grease filters. Push the  
catch towards the inside and remove the charcoal filter  
from its seat.  
Careful maintenance will assure good functioning and  
good efficiency over time.  
Cleaning the hood  
Any fat deposits should be removed from the appliance  
periodically depending on amount of use (at least every  
2 months). Avoid using abrasive or corrosive products.  
To clean painted appliances on the outside, use a cloth  
dipped in lukewarm water and neutral detergent. To  
clean steel, copper or brass appliances on the outside,  
it is always best to use specific products, following the  
instructions on the products themselves. To clean the  
inside of the appliance, use a cloth (or brush) dipped in  
denatured ethyl alcohol.  
Replace the charcoal filter with one of the same type  
by carrying out the operations in reverse order.  
Replace the charcoal filter on average every 6 months  
depending on how heavily the hood is used.  
Cleaning the grease filters  
To remove the grease filters, push the catch near the  
handle towards the inside and pull the filter  
downwards.  
Replacing the lamps  
Pay particular ATTENTION when carrying out  
this operation and remember to remove the voltage.  
To replace the halogen lamps, open the cover  
by prising in the slots. Replace with lamps  
of the same type.  
WARNING: Do not touch the new lamp with bare  
hands.  
Wash the filters by hand or in the dishwasher using  
a neutral detergent. If they are washed  
in the dishwasher, any loss of colour will  
not jeopardise functioning of the filters in any way.  
Clean the grease filters every 2 months on average  
depending on how heavily the hood is used.  
7
 
Precautions and tips  
04307812  
General safety  
Disposal  
GB  
!
The distance between the supporting surface for  
the cooking vessels on the hob and the lower part  
of the hood must be at least 65 cm.  
If the instructions for installation for the hob specify  
a greater distance, this has to be taken into account.  
ATTENTION: This appliance must be grounded.  
When making the electrical connection, ensure  
that the power outlet is earthed.  
When making the electrical connections, check  
that the current socket has a ground connection.  
Avoid using materials which could cause spurts  
of flame (flambées) near the appliance.  
When frying, take particular care to prevent oil  
and grease from catching fire. Already used oil  
is especially dangerous in this respect.  
The European Directive 2002/96/EC on Waste  
Electrical and Electronic Equipment (WEEE), requires  
that old household electrical appliances must  
not be disposed of in the normal unsorted municipal  
waste stream.  
Old appliances must be collected separately in order  
to optimise the recovery and recycling of the materials  
they contain and reduce the impact on human health  
and the environment.  
The crossed out “wheeled bin” symbol on the product  
reminds you of your obligation, that when you dispose  
of the appliance it must be separately collected.  
Consumers should contact their local authority or  
retailer for information concerning the correct disposal  
of their old appliance.  
!
!
!
!
!
Do not use uncovered electric grates.  
Do not place weights above the hood.  
Air vent  
Should you install the ducting version, prepare the air  
vent hole and duct.  
In the Ducting version, to get optimal conditions the air  
venting pipe should: be as short as possible, have the  
lowest number of bends (max bende angle: 90°, be  
made of material approved by local authorities  
(according to the State), have its inner side as regular  
and smooth as possible. It is moreover recommended  
to avoid drastic changes of pipe cross section  
(recommended diameter: 150 mm).  
!
The air collected must not be conveyed into a duct  
used to blow off smokes from appliances fed with  
an energy other than electricity (central heating  
systems, thermosiphons, water-heaters, etc.).  
Comply with the official instructions provided by  
the competent authorities in merit when installing  
the disposal duct. In addition, exhaust air should  
not be discharged into a wall cavity, unless  
the cavity is designed for that purpose.  
!
!
The room must be well aerated in case a hood  
and some other heat equipment fed with an energy  
other than electricity (gas, oil, coal heaters, etc)  
operate at the same time. In fact the ducting hood,  
disposing of air, could create a vacuum in the room.  
The vacuum should not exceed 0,04mbar.  
This prevents the gas exhausted by the heat source  
from being intaken again. It is therefore advisable  
to ensure the room contains air taps able to ensure  
a steady flow of fresh air.  
8
 

Graco Inc Power Roller 287713 User Manual
Guardian Technologies Telephone SCR 11 User Manual
Hasbro Robotics 83612 User Manual
Heath Zenith Work Light UT 5592 BZ User Manual
Honeywell Network Router 800 08340V1 User Manual
Hoshizaki Ice Maker KM 501MAH User Manual
HP Hewlett Packard TV Converter Box 8560A User Manual
ICP DAS USA Switch MSM 508FT User Manual
iHome Portable Speaker IH170 User Manual
i Tech Dynamic Headphones IIe User Manual