Aiphone LAF C CONSOLE MASTER LAF 20C User Manual

92101 0705  
LAF-C Console Master Loudspeaker Intercom System  
Type F  
- INSTRUCTIONS -  
The LAF-C Console Master system is a loudspeaker type, single talkpath open voice system. Multiple masters  
can be used, along with a large variety of sub station models to create a communication system tailored to the  
user's needs. Master stations are available in 20-and 40-station sizes, with or without a handset. For greater  
capacity, include a 20- or 40-station add-on selector. Any "LE-" or "LS-" series sub station can be used.  
All Call and/or Background Music are optional features requiring additional equipment (BG-10C, PS-1225UL).  
NAMES & FEATURES  
LAF-20CA (pictured)  
NAMES & FUNCTIONS:  
1. Handset  
2. Power indicator  
3. Microphone  
4. Speaker  
5. Terminal Block  
6. OFF button  
7. Selector button  
8. Power switch  
9. Voice volume control  
10. Call tone volume control  
11. All Call button  
12. TALK button  
13. Occupied LED  
14. OFF LED  
15. Directory card  
16. Station selector LED  
FEATURES:  
· Single or multi-master capability  
· Commercial grade, durable master station for heavier usage  
· Master stations available with or without a handset  
· Single talkpath, with push-to-talk operation or handset at master, and hands free communication  
at sub station  
· Large variety of sub stations available  
- Surface or flush mount, with or without privacy (LE-A, LE-AN, LE-B, LE-BN)  
- Weather resistant door stations (LE-D, LE-DA, LE-DL)  
- Vandal proof sub station (LS-NVP/B, SBX-NVP surface mount box)  
· Selective calling to sub stations, and master-to-master communication  
· Subs call in with momentary tone and LED, remaining lit for approximately 20 seconds  
· Optional All Call (additional equipment required) to call all stations simultaneously  
· Equipment used for All Call also allows for background music to be heard through master and subs  
· Master is desk or wall mountable. LAF-20CA can be rack mounted in RMK-01 rack mount kit.  
LAF-20C can be rack mounted in RMK-03 rack mount kit.  
· 20- and 40-call add-on selectors available, with LA-40AS rack mountable with RMK-02.  
Pg. 1  
WIRING DIAGRAMS  
3a. SINGLE MASTER SYSTEM, NO ALL CALL  
LAF-20C  
LE-A  
1
LE-A  
1
1
2
3
4
5
LE-D  
1
SA-  
1
E
-
E
-
E
-
SA-1 for optional  
surge protection  
(See note #3.)  
~
LE-D  
1
20  
E
E
E
E
E
-
SA-  
1
All "E" terminals are  
common internally.  
NOTES:  
Two wiring method can be used:  
-
C
R
Y
P1  
P2  
P3  
+
1. 2 conductor homerun to each sub station from the master.  
(Single master system only.)  
SA-  
1
2. Run multi-conductor wire in a daisy-chained fashion with 2  
common wires (E & -) plus one individual wire per station on the run.  
PS-1225UL  
Remove jumpers between E & - when daisy-chained method is used.  
+
-
-
3. To protect system from power surge, install SA-1 arrestors at master  
station. One SA-1 is required for every two wires connected to master.  
3b. DUAL MASTER SYSTEM WITH MASTER-TO-MASTER COMMUNICATION  
LAF-20CA  
LAF-20CA  
LE-DA  
1
LE-DA  
1
1
2
3
1
2
3
LE-DA  
1
LE-DA  
1
~
~
19  
19  
Remove  
E/- jumpers  
E
-
E
-
E
-
E
-
E
-
E
-
20  
C
R
C
20  
R
Master-to-master  
communication is shown  
on channel 20 of each  
master.  
Y
Y
P1  
P2  
P3  
P1  
P2  
P3  
Y, P1, P2, P3  
WIRING NOTE:  
terminals used only if  
All Call Adaptors are  
included.  
The following sub stations  
are wired as shown above:  
· LE-A, LE-AN  
· LE-B, LE-BN  
· LE-D, LE-DA  
PS-1225UL  
+
+
-
+
-
-
RY-AC for external signalling  
when sub calls  
Blk  
Red  
Wht  
To external signalling device and power  
(E.g. Station #19 will actvate ext. device  
when it calls in to master.)  
RY-AC  
Yellow  
Pg. 3  
WIRING DIAGRAMS  
3c. THREE MASTER STATIONS WITH SUBS WIRED TO DIFFERENT MASTERS  
LAF-40CA  
LAF-40CA  
LAF-40CA  
LS-NVP  
Red  
LS-NVP  
Red  
1
2
3
1
2
3
1
2
3
LS-NVP  
Red  
~
~
~
LS-NVP  
Red  
37  
37  
37  
Blk  
Grn  
Blk  
Grn  
E
-
E
-
E
-
Blk  
Grn  
Blk  
Grn  
C
39  
40  
R
38  
C
40  
R
38  
39  
C
R
Y
Master-to-master  
communication  
Remove  
E/- jumpers  
NOTE:  
Y
Y
When wiring LS-NVP  
subs with two wires,  
black and green wires  
are tied together at sub,  
and "E" and "-" terminals  
are jumpered at master.  
P1  
P2  
P3  
P1  
P2  
P3  
P1  
P2  
P3  
+
-
+
-
+
-
+
-
PS-1225UL  
3d. MASTER STATION WITH ADD-ON SELECTOR  
LAF-20CA  
LE-D  
1
LA-40AS  
LE-DA  
1
LE-D  
1
2
3
1
2
3
LE-D  
1
1
~
~
LE-DA  
1
40  
20  
E
-
E
-
E
-
E
-
E
-
E
-
R
Blk  
Yel  
WIRING NOTE:  
X1  
X2  
X3  
X4  
X5  
X6  
X7  
X8  
The following sub stations  
are wired as shown above:  
· LE-A, LE-AN  
· LE-B, LE-BN  
· LE-D, LE-DA  
Wiring from  
Add-on Selector  
Org  
Gry  
Brn  
Red  
Wht  
Grn  
NOTE:  
LA-20AS wires  
the same as  
shown here.  
PS-1225UL  
+
-
+
-
Pg. 4  
WIRING DIAGRAMS  
Pg. 5  
OPERATIONS & SPECIFICATIONS  
OPERATIONS:  
* POWER SWITCH MUST BE ON FOR THE SYSTEM TO BE OPERATIONAL.  
Receiving a call from a sub station:  
1. Sub station calls in with mono-electronic tone, heard as long as call button at sub is depressed.  
2. LED light corresponding to calling station will light at master, staying on approximately 20 seconds.  
3. Depress station button with lit LED.  
4. Press TALK button to speak, and release to listen. With handset model (LAF-CA), speak to sub station  
privately with voice actuated (VOX) handset. TALK button is also functional on LAF-CA models.  
5. Press OFF button to the left of the station selector button when the call is concluded.  
Calling a sub or master station:  
1. Depress station number of the location you wish to call.  
2. Press TALK to speak, and release to hear reply, or use handset.  
3. If you wish to send a pre-announce tone to the called station, press the TALK and ALL CALL buttons  
simultaneously. A mono-electronic tone will be heard at the called station.  
4. Press OFF button to the left of the station selector button when the call is concluded.  
Receiving a call from another master station:  
1. When one master calls another master, no station LEDs light up, and the responding master answers back  
hands free. The calling master uses the TALK button to speak.  
2. The calling master can use the handset, but the responding master must speak hands free.  
3. The "occupied lamp" will be on while the initiating master has a station selected.  
4. The responding master should not press any buttons to respond to another master's call.  
Initiating an ALL CALL from the master station, and features of the BG-10C:  
1. Press and hold the black ALL CALL button, then make an announcement.  
2. To conclude, simply release the button.  
3. All Call is a one way outgoing announcement only. If a station wishes to respond, they must press their call  
button, and the master station can then answer the call as described above.  
4. If background music is included, the music will be heard on the system while it is not occupied. When any  
master station selects a station to place or answer a call, the music will be muted throughout the entire  
system.  
5. If a door station is wired to the BG-10C to produce a chime, a 4-stroke chime will be heard through the  
stations selected to receive the chime (switches under plate on BG-10C). A call from a door station can  
only be answered by a master station.  
SPECIFICATIONS:  
Power Source:  
12V DC at master. Use one PS-1225UL per system,  
or one PS-1225UL per BG-10C when All Call is included.  
Communication Output: 800mW at 20 ohms (receive); 500mW at 20 ohms (transmit)  
Communication:  
Push-to-talk, release-to-listen (TALK button), or VOX handset at master.  
Hands free at sub station.  
Calling:  
Master to sub or other master: By voice (TALK) or tone (TALK & ALL CALL simult.)  
Sub to master: Call button on sub activates tone and LED at master,  
remaining lit for approximately 20 seconds.  
Wiring:  
2 conductors homerun to sub station (1-Master system only), 3-conductor, or loop multi-  
conductor with 2 common + 1 individual wire per sub station on wire run.  
Shielded cable is recommended.  
Single Master Systems without BG-10C:  
Aiphone #822202, 2 cond. 22AWG; #821802, 2 cond. 18AWG  
Multi-Master System (Can also be used in a single master system or systems with BG-10C):  
#822203, 3 cond. 22AWG; #822206, 6 cond. 22AWG.  
LAF-C to ea. BG-10C: Aiphone #822220, 20 cond. 22AWG.  
650' with 22AWG; 1,600' with 18AWG.  
Wiring Distance:  
Dimensions:  
(H x W x D)  
LAF-20C: 10-1/4" x 13-1/2" x 5-1/2".  
LAF-40C: 10-1/4" x 19-1/2" x 5-1/2".  
LA-20AS: 10-1/4" x 7" x 5-1/2".  
LAF-20CA: 10-1/4" x 17-3/4" x 5-1/2"  
LAF-40CA: 10-1/4" x 23-1/2" x 5-1/2"  
LA-40AS: 10-1/4" x 12-7/8" x 5-1/2".  
Pg. 6  
TROUBLESHOOTING GUIDE  
SOLUTION  
PROBLEM  
1. Make sure jumper is installed between E & -  
terminals at the master and all sub stations (in 2-wire  
configuration).  
1. No call tone or LED when sub calls master.  
2. Same as #1 in 2-wire system. In 3 wire system, 1 &  
E are for communication, and 1 & - are for call-in. Check  
continuity and connection of wires.  
2. Call tone works, but no communication, or  
communication works, but no call tone.  
3. Call tone volume control is located on main PC board  
under select switch panel (white 3-pos. switch). Level is  
set to maximum. Move to mid or low position.  
3. Call tone is too loud or too quiet.  
4. The "C" terminal on the master station means  
"CALL", and provides master-to-master communication.  
Make sure the "C" of one master is connected to a  
designated station # on another master.  
4. Master stations cannot call each other.  
5. Station LEDs only light when a sub station calls.  
Responding master answers hands free, therefore not  
having to select a station.  
5. LED lights don't light up when calling master-to-  
master.  
6. Make sure all black OFF buttons on master(s) are off  
(pressed down). Check "R" wire for short to ground. If  
occupied light remains lit with "R" wire disconnected  
from master, internal damage has occured, and the unit  
must be sent in for repair.  
6. Occupied light is always on.  
7. Make sure station number wires aren't shorted  
together. Remove all jumpers between E & - in multi-  
master or 3-wire system. Test master by taking wires off  
# terminals, then momentarily shorting # terminal to -  
(neg). If more than one light comes on, internal damage  
has occured, and the master must be repaired.  
7. When subs call in, multiple LEDs light up.  
8. All Call is an optional feature requiring a BG-10C and  
PS-1225UL for every 10-11 stations in the system.  
Make sure adaptors are wired properly. See diagram  
#3e.  
8. All Call doesn't work.  
9. All call doesn't work, but adaptors are included.  
9. Check connection of P1, P2, P3 terminals between  
master and BG-10C's. P1 should read at least 10V DC  
when All Call button is pressed. Voice is carried on P2,  
P3 wires.  
10. When All Call is made, all station LEDs light up.  
10. If single-call sub stations are used, NP-25V  
capacitors must be installed as shown on diagram #3e.  
11. Feedback is heard between intercom stations in  
adjacent rooms.  
11. Intercom stations should not be mounted back-to-  
back on a common wall. Separate them by at least two  
feet, or on separate walls if possible. Adjust voice  
volume control to eliminate feedback.  
12. System has AC hum when listening to another  
station from a master station.  
12. Intercom wiring must be at least 20" away from any  
AC wiring, fluorescent lights dimmer switches, or other  
AC devices. Cross at 90 degrees when necessary. If  
shielded wire was used, tie all shields together and  
ground at one end to an earth ground. If noise persists,  
isolate source of noise and separate the intercom station  
and wiring from the source.  
Pg. 7  
PRECAUTIONS & WARRANTY  
CAUTION  
* Do not connect any AC wires to any terminal on any unit, as fire or unit damage may occur. Connect only  
specified power source on +, - terminals.  
* Do not install more or different power sources than specified for the system.  
* Do not attempt to install or connect wires on LAF-C system while the system's power supply is plugged in.  
* LAF-C masters and related equipment, unless specified as "weather resistant", are designed for indoor use only.  
Door stations (LE-D, LE-DA, LE-DL) may be installed outdoors.  
IMPORTANT  
* There is no need to disassemble the equipment for installation. Call tone volume and handset vox sensitivity  
adjustments are inside the master station, and are the only controls to be accessed inside the unit. Do not access  
the PC boards inside the units unless properly qualified.  
* Any other manufacturer's products installed with the system (power supply, external signalling device, etc.) are not  
covered under Aiphone's warranty.  
* Do not mount LAF-C equipment in the following places, as it may cause the system to malfunction:  
- High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature,  
front of air conditioner, inside a refrigerated area, etc.  
in  
- Places subject to moisture or humidity extremes.  
- Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.  
* LAF-C units are electronic devices, which must not be subjected to water or any other liquid.  
* Severe weather conditions, such as lightning storms, may cause damage to LAF-C equipment. We recommend  
that power surge protection be installed to minimize potential component level damage.  
- Install the SA-1 surge arrestor as shown to protect the power supply from a surge.  
- Additional SA-1 surge arrestors should be installed on all communication lines (one SA-1 for every two wires  
connected to master.) See diagram #3a.  
LAF-C Master  
PS-1225UL  
+
-
+
-
SA-  
1
Earth Ground  
WARRANTY  
Aiphone warrants its products to be free from defects of material and workmanship under normal use  
and service for a period of one year after delivery to the ultimate user and will repair free of charge or  
replace at no charge, should it become defective upon which examination shall disclose to be defective and  
under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a  
defect in materials and/or workmanship; and whether or not the product is within the warranty.  
This warranty shall not apply to any Aiphone product that has been subjected to misuse, neglect,  
accident, or to use in violation of instructions furnished, nor extended to units which have been repaired or  
altered outside of the factory. This warranty covers bench repairs only, and any repairs must be made at the  
shop or place designated in writing by Aiphone.  
Aiphone will not be responsible for any costs incurred involving on-site service calls.  
Toll Free Technical Support  
1-800-692-0200  
TOLL FREE FAX LINE:  
1-800-832-3765  
Aiphone Communication Systems  
1700 130th Ave. N.E.  
Bellevue, WA 98005  
(425) 455-0510  
Pg. 8  
LAF-C Instr.  
Lit #92101  
0705JS  
FAX (425) 455-0071  

Briggs Stratton 6R 6 User Manual
Brother Printer MFC 8640D User Manual
Cannon Answering Machine MX360 User Manual
Canon PIXMA MP830 User Manual
Emerson ACM1000M XXX User Manual
Friedrich 49 User Manual
Friedrich YS12M33 User Manual
GE ASV12 User Manual
GE Zoneline AZ28E09DAC User Manual
HP Hewlett Packard CH350 90038 User Manual