Friedrich P12A User Manual

Installation & Operation Manual  
Portable Air Conditioner  
Models P09A and P12A  
PAC-IO (10-07)  
Unit Identification and Function  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
10.  
Control panel  
Air outlet  
Signal receptor  
Handle  
Caster  
Air outlet hose  
Air lter  
Air intake hose  
1/2" water outlet drain  
Power supply cord  
3
Control Panel Operation  
Dehumidifying and cooling operation  
Mode control  
The operating range for cooling operation is 60°F - 90°F,  
and the operating range for dehumidifying is 68°F-88°F.  
The mode control has three settings– Cool, Dehumidify and  
Fan. The settings are adjusted with the Mode Control button.  
A light will indicate which setting is currently being used.  
Power source  
• The AC socket must be rm and reliable.  
Cooling operation  
1. Press MODE button to choose the cooling mode, LCD  
window will show “cool”.  
• Don’t connect the portable air conditioner to a multiple socket  
outlet which is also being used for other electrical appliances.  
During the cooling operation, always place the air exhaust  
hose through an open window.  
• Insert the AC power plug securely into the AC socket before  
using the unit, when it beeps after two seconds, press ON/  
OFF button, the unit begins to run.  
2. Repeatedly press TEMP+ or TEMP- button to set a proper  
room TEMP. between 60°F - 90°F.  
LCDI power cord information  
3. Press FAN SPEED button to choose between low and high  
speeds.  
All Friedrich portable air conditioners are shipped from the  
factory with a Leakage Current Detection Interrupter (LCDI)  
equipped power cord. The LCDI device meets the UL and  
NEC requirements for cord connected air conditioners effec-  
tive August 2004.  
NOTE:  
In order to improve the cooling efciency:  
a) If your room is directly exposed to the sun, draw the curtains.  
b) Do not place near other heat source.  
To test your power supply cord:  
1. Plug power supply cord into a grounded 3 prong outlet.  
2. Press RESET (See drawing below).  
Dehumidifying Operation  
1. Keep the windows and the doors closed to aid in effectively  
dehumidifying the room.  
3. Press TEST (listen for click; Reset button trips and pops out).  
4. Press and release RESET (listen for click; Reset button  
latches and remains on). The power supply cord is ready  
for operation.  
2. Press MODE button to choose the dehumidifying mode, LCD  
window will show “DRY”, the fan speed cannot be adjusted.  
When used as dehumidier only it is not necessary to install  
the exhaust hose.  
NOTE: LCDI device is not intended to be used as a switch.  
Once plugged in the unit will operate normally without the  
need to reset the LCDI device.  
Time Set Function  
To set the time to start the machine, with the unit off (but power  
supplied), press TIMER button, the LCD window will show “  
”, continually press the TIMER button, set the preferred  
start time. The setting range is 1-24 hours.  
If the device fails to trip when tested or if the power supply  
cord is damaged it must be replaced with a new supply cord  
from the manufacturer. We recommend you contact our Tech-  
nical Assistance Line at (800) 541-6645. To expedite service,  
please have your model and serial number available.  
To set the time to stop the machine, with the unit running,  
press TIMER button, the LCD window will show “  
”, con-  
tinually press the TIMER button ,set the preferred time to stop  
the machine. The setting range is 1-24 hours  
WARNING: NEVER  
CUT OR REMOVE  
THE GROUNDING  
PRONG FROM  
NOTE: During timer mode if the TIMER button is pressed  
again it will cancel the timer operation.  
PLUG. NEVER USE  
EXTENSION CORDS  
TO OPERATE AN  
Warning Light  
Condensed water may accumulate in the unit. If the internal  
tank becomes full, the Warning Light will come on and the unit  
will not operate until the unit has been drained.  
AIR CONDITIONER.  
Test Button  
Reset Button  
4
Remote Control Identification and Function  
Time/Temperature Set Control  
Used for adjusting the timer and temperature  
The default display on control panel is room  
temperature.  
When the "  
" or the "  
" button is pressed  
in cool mode, the set temperature is displayed  
and may be adjusted. After 15 seconds the  
display will revert back to room temperature.  
Power Control  
Timer setting is available from 1-24 hours by  
On/Off  
pressing the button "  
" on "  
".  
Fan Speed Control  
Mode Control  
: HIGH  
: MED  
:LOW  
Press this button to change the operation  
mode in the order of:  
Cool Dry Fan  
Farenheit/Celscius Control  
Press this button to change back  
and fourth from Farenheit to  
Celcius temperature readings  
Timer control  
In running mode:  
Auto switch off  
In standby mode:  
Auto switch on  
Press the "  
" or the "  
" button to  
adjust the time setting for 1 hour interval.  
5
Window installation  
Window adapter kit  
An installation parts kit is packed with your unit in a separate  
carton. Before you discard the packaging that your unit came  
in, please locate the carton that contains these parts and  
ensure that all parts are present.  
Window panel extensions  
Window panel  
Window panel Attaches to window opening to  
allow air exchange for system air  
transfer.  
Window panel extensions Extends window panel to fit  
Screws  
windows of various dimensions.  
Tube Adapters  
Tube adapters Connect Air exchange tubes to  
window panel.  
Screws 12 screws are included for  
assembling the window adapter  
kit. Some screws may be partially  
assembled onto window panel.  
Air exchange tubes Exchanges air between the unit  
and outdoors.  
Minimum window extension  
Maximum window extension  
Minimum hose extension  
Maximum hose extension  
26"  
46"  
20"  
60"  
Air Exchange Tubes  
Instructions for assembling the window adapter kit  
Back of  
window panel  
1. Insert tube adapters through the back of the window panel.  
2. Secure each tube adapter with four screws through the  
front of the window panel.  
3. Insert window panel extensions into window panel. Lightly  
tighten the screws in the window panel to hold the  
extensions in place.  
Tube Adapters  
Window Panel  
Extension screws  
Window Panel  
Extension  
Window Panel  
6
Installing the window adapter kit  
Note: The window adapter kit must be installed and con-  
nected for the air conditioner to work properly in Cool mode.  
The window adapter kit is not required when using the unit  
in Dehumidify or Fan modes.  
Your window adapter kit has been designed to t most stan-  
dard vertical and horizontal window applications. However,  
it may be necessary for you to modify some aspects of the  
installation procedures for certain types of windows.  
1. Open window.  
2. Place window panel with extensions into windowframe  
and adjust to width of window.  
Window adapter kit may be installed vertically aswell as  
horizontally. This installaton may also be used for crank  
style windows.  
3. Tighten the four screws on the window panel to secure  
the window panel extensions.  
4. Close window.  
5. The window adapter kit should now t securely within  
the window frame and you can now attach the air ex-  
change tubes. If you are having trouble attaching the air  
exchange tubes, you may attachthe tubes prior to install-  
ing the window adapter kit.  
Attaching the air exchange tubes to the air  
conditioner  
1. Attach the tubes to the window adapter kit.  
2. Attach the other end to the air conditioner.  
To attach air exchange tubes: push tube onto tube adapter  
and twist until the tab is in place in the hole on the tube.  
To remove air exchange tubes: twist the end until the tab is  
clear of the hole in the tube and pull off.  
Do not attach the tubes if using the unit in dehumidify  
mode.  
Maintain a clear distance (from walls, furniture, etc.)  
of at least 10 inches around the unit to allow proper  
air circulation and prevent damage to the unit.  
Important: Do not over-stretch the exhaust tube or-  
make any unnecessary bends in it.  
7
Condensation Handling  
Draining Water  
The water can be drained from the unit by removing the base  
stopper and letting the water drain by gravity.  
Your ZoneAire® Portable Air Conditioner is designed to evapo-  
rate the condensation removed from the interior space through  
the exhaust hose. Under certain conditions it is possible that  
the unit will not evaporate 100% of the removed moisture.  
1. When the WATER FULL lamp is on unplug the unit and move  
the unit to a suitable location for draining the condensation.  
The unit is designed with a built-in reservoir to accumulate  
excess condensate and help dispose of it.  
2. Using the gravity drain method, ensure that the base stop-  
per is located above a suitable area for draining the conden-  
sate and remove the stopper. Re-install the stopper once all  
water has drained.  
Internal Water Level  
1. Under any mode if the water level is in the “low” area the  
3. Return the unit to the original location and restore power  
and duct connections.  
unit will function normally.  
2. If the water level is in the “normal” area the unit will con-  
tinue to function normally while internally evaporating the  
condensate.  
4. The WATER FULL indicator should be off and the unit will  
return to normal operating mode.  
3. If the unit cannot evaporate all of the condensate internally,  
the tank may become full. If the tank becomes full, the unit  
will turn off, and the Water Full light will illuminate.  
Permanent Drainage  
For permanent and continuous drainage, a 1/2" hose may be  
attached to the unit and led down a drain.  
Drain Valve  
8
Maintenance /Service  
WARNING  
Disconnect the power before cleaning.  
!
Make sure there is no power to the unit before  
beginning to maintain or repair the unit in order  
to prevent accidents caused by electrical shock.  
Cleaning the air filter  
If the air lter is blocked with a lot of dust, the air ow volume  
will be reduced. Clean the lter once every two weeks.  
Open and clean the air lter:  
1. Pull the lter out as shown in the drawing.  
2. Take out the air lter from the lter cover.  
3. Wash the air lter by immersing it gently into warm (about  
40°C or 104°F) water with a neutral detergent or vacuum  
the lter clean.  
4. Rinse the lter and dry it thoroughly in a shaded place.  
5. Install the air lter back to its original place.  
Cleaning the air conditioner  
Clean the surface of the unit with a damp cloth, then dry using  
a duster or similar.  
Preparation for storage  
1. Turn off the air conditioner, disconnect the power.  
2. Perform proper maintenance to the air lter and other parts.  
CAUTION  
!
3. Open the base stopper to drain out all of the water from the  
base. Operating the unit in fan only mode for 12 hours will  
help ensure there is no moisture within the unit.  
Do not use chemical solvent (like benzene or alcohol) to clean the  
surface of the unit. If you do so, the surface may be scratched,  
damaged or even cause the case to become deformed.  
4. Cover the unit to prevent dust or lth from entering the unit.  
Prior to operating seasons  
1. Check to ensure that the air inlets and outlets of the unit  
Drain valve  
are not blocked.  
2. Make sure that air lter is properly in place before operat-  
ing the machine. If the machine is operated with air lter  
removed, dust and foreign objects will result in faulty per-  
formance of the air conditioner.  
CAUTION  
WARNING  
Power Sources  
!
!
Safety Precautions  
• Do not use a damaged or improper AC socket.  
• Make sure the unit is installed in an accessible location.  
• When unplugging the unit, hold the power plug securely  
and pull it out carefully.  
• Do not locate the unit in direct sunlight so as to avoid discol-  
oration of the plastic.  
• Never use an extension cord with this air conditioner.  
• Do not use the unit in water or near water to avoid electrical  
shock.  
Other Warnings  
• Keep the unit one meter away from TV sets or radios to  
avoid the risk of electromagnetic interference.  
• Do not use near gas appliances, res or in the vicinity of  
ammable liquids.  
• Only operate the unit in the appropriate upright position.  
• Ensure that the discharge air outlet is free from obstruc-  
tions and not impeded by walls or other structures.  
9
Troubleshooting  
Before seeking repair or service, please check the following rst:  
Trouble  
Check  
Action  
Is there power?  
Is it plugged in?  
Is the fuse or circuit breaker switch off?  
Is timer on?  
Push the plug into the wall socket  
Change the fuse or reset breaker  
Pres TIMER button  
Air conditioner does  
not operate  
Is air inlet or outlet blocked?  
Is there any other heat source in the room?  
Are air lters dirty?  
Clear the air path  
Move the unit away from heat source  
Clean the air lter  
Set to a suitable temperature  
Set to a suitable fan speed  
The sound may be normal  
Move unit to a level location  
Cooling efciency  
is not good  
Is SET TEMP suitable?  
Is indoor fan speed set at low?  
Is the sound part of the refrigeration cycle?  
Is unit leveled?  
Too much noise and  
vibration  
Is the voltage of the power source correct and continuous? Repair the power source  
Is the air exhaust bent? Try to keep the air exhaust horizontal  
The machine starts  
and stops frequently  
WARNING  
In case of major malfunction, disconnect power immediately and call for service.  
!
10  
Friedrich Air Conditioning Company  
P.O. Box 1540  
San Antonio, TX 78295  
210.357.4400  
PORTABLE AIR CONDITIONERS  
LIMITED WARRANTY  
FIRST YEAR  
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from  
date of original purchase, FRIEDRICH will repair the product at no charge, provided the product is transported to a Friedrich  
Authorized Service Center for repair. ALL transportation charges are the sole responsibility of the owner. This remedy is expressly  
agreed to be the exclusive remedy within twelve months from the date of the original purchase.  
SECOND THROUGH FIFTH YEAR  
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser  
coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in  
your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase,  
FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will  
not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the  
Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the  
sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the  
original purchase.  
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District  
of Columbia, and Canada. This warranty is not applicable to:  
1. Air filters or fuses.  
2. Products on which the model and serial numbers have been removed.  
3. Products which have defects or damage which results from improper installation, wiring, electrical current  
characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication  
of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war,  
government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.  
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service  
Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write  
to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.  
LIMITATIONS:  
THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty  
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY  
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND  
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR  
IMPLIED WARRANTY.  
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of  
consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.  
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.  
All service calls for explaining the operation of this product will be the sole responsibility of the consumer.  
All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to  
repairs being made.  
11  
Friedrich Air Conditioning Co.  
Post Office Box 1540 • San Antonio, Texas 78295-1540  
4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212  
(210) 357-4400 • FAX (210) 357-4480  
PAC-IO (10-07)  

Boston Acoustics DSI285 User Manual
Briggs Stratton 6FBP User Manual
Briggs Stratton 170799 User Manual
Bryant Air Conditioner 550A User Manual
Epson Stylus Deluxe Photo Printer PICTUREMATED User Manual
Friedrich Air Conditioner CP12A10 User Manual
Friedrich Air Conditioner E S12 User Manual
Friedrich PE15R__B User Manual
Fujitsu RO 36FA User Manual
GE General Electric Air Conditioner AG_12 12 User Manual