Oxygen COnCentratOr
User ManUal
Model numbers JB0160-010B, JB0160-010,
JB0160-010B-220, JB0160-010-220
and
JB0160-015B, JB0160-015, JB0160-015B-220,
JB0160-015-220 with O2 sensor
Important: Do not operate this concentrator without
first reading and understanding this manual!
save this manual for future use.
Federal Law (USA) restricts this device to sale by or
on the order of a physician. This product should not
be used unless the operator has been instructed by a
qualified health care professional.
WARNING: Users who require continuous oxygenation
must plan for alternate reserve sources of power and
oxygen in the event of a failure or loss of power and
oxygen. This device is to be used ONLY as an oxygen
supplement device and is NOT intended to be a life-
supporting or life-sustaining device.
1 safety
The John Bunn O2 Premier oxygen concentrator is intend-
ed for use as an oxygen supplement device in a home or
care facility. Use the concentrator only as prescribed by a
physician. This user manual serves as a reference for your
oxygen concentrator.
Important Information
Please note the following special statements, used
throughout this manual, and their significance:
Note: Explanatory information.
Damage: Action could result in damage to equipment.
ATTENTION: Action could result in personal injury.
CAUTION: Action could result in electric shock.
WARNING: Action could result in fire and explosion.
s
Before Installation
Damage: During transport, always keep the concentrator
upright to prevent damage.
s
Damage: Only use stable and safe electrical power
sources.
s
John Bunn Oꢀ Premier Oxygen Concentrator
3
Damage: If the electrical power source becomes
unstable, discontinue use and find an alternate source.
s
s
Damage: The oxygen concentrator cabinet contains no
serviceable parts! The oxygen concentrator cabinet
should ONLY be opened by an authorized equipment
provider.
Placement
ATTENTION: The oxygen concentrator is intended to
be rolled from room to room. Do not place the oxygen
concentrator in surroundings where its airflow is
obstructed.
ATTENTION: Be certain to place the unit so that all sides
are at least 12 inches (30 cm) away from walls, draperies,
furniture, or other obstructions. Do not place the unit in a
confined area.
ATTENTION: The oxygen concentrator MUST be kept
away from heat, fire and excessive water sources and
conditions.
ATTENTION: Do not place items on top of the
concentrator.
ATTENTION: NEVER block the concentrator’s air openings.
ATTENTION: Always place the concentrator on a hard
surface. Never place the concentrator on a surface such
as bed or couch, where the concentrator may tip or fall.
ATTENTION: Keep the concentrator openings free from
lint, hair, etc.
fire Warning & explosion
WARNING: Keep the concentrator away from flammable
and explosive areas.
4
John Bunn Oꢀ Premier Oxygen Concentrator
WARNING: To reduce the risk of fire, special care must
be taken when using oxygen concentrators. DO NOT
SMOKE while using this device. Keep all matches, lighted
cigarettes or other sources of ignition out of the room in
which this concentrator is located. In public settings or
when used in hospital or long-term care environments,
prominently display NO SMOKING signs.
WARNING: Textiles and other materials that normally
would not easily burn, can ignite and burn with great
intensity in oxygen enriched air.
WARNING: A spontaneous and violent ignition may occur
if oil, grease or greasy substances come in contact with
oxygen under pressure. ALWAYS keep these substances
away from the oxygen concentrator and all other
oxygen equipment. DO NOT use any lubricants unless
recommended by manufacturer.
WARNING: Failure to observe these warnings can result in
severe fire, property damage and cause physical injury or
DEATH.
Maintenance
CAUTION: The oxygen concentrator was specifically
designed to minimize routine preventive maintenance.
Only an authorized equipment provider or factory-trained
personnel should perform preventive maintenance or
adjustments to the oxygen concentrator.
Radio frequency Interference
Most electronic equipment is influenced by Radio Fre-
quency Interference (RFI). ALWAYS exercise CAUTION with
regard to the use of portable communications equipment
in the area around such equipment.
John Bunn Oꢀ Premier Oxygen Concentrator
5
additional safety Warnings
WARNING: TO REDUCE THE RISK OF BURNS,
ELECTROCUTION, FIRE OR INJURY TO PERSONS, avoid
using while bathing. If continuous usage is required by
the direction of a physician, the concentrator must be
located in another room at least 9 feet (2.8m) from the
bath.
WARNING: DO NOT reach for a concentrator that has
fallen into water. UNPLUG IT IMMEDIATELY.
WARNING: In certain circumstances, oxygen therapy can
be hazardous. Graham-Field recommends that you seek
medical advice before using this product.
WARNING: Avoid creation of any spark near medical
oxygen equipment. This includes sparks from static
electricity created by any type of friction.
ATTENTION: DO NOT come in contact with the concentrator
when you are wet.
ATTENTION: DO NOT place or store the concentrator where
it can drop into water or other liquid.
ATTENTION: NEVER leave the concentrator unattended
when plugged in.
ATTENTION: This device is to be used only in accordance
with the prescription of a physician and this user manual.
If at any time the patient or attendant concludes that
the patient is receiving an insufficient amount of oxygen,
contact the provider and/or physician immediately.
NEVER make adjustments to the flow rate unless
prescribed by a physician.
6
John Bunn Oꢀ Premier Oxygen Concentrator
ATTENTION: ALWAYS supervise closely when this
product is used near children or those who require close
supervision.
ATTENTION: Only use this device as intended and
described in this manual.
ATTENTION: DO NOT use parts, accessories or adapters
other than those authorized by manufacturer.
ATTENTION: DO NOT connect the concentrator in parallel
or series with other oxygen concentrators or oxygen
therapy devices.
ATTENTION: JB0160-015B, JB0160-015, JB0160-015B-220
and JB0160-015-220 only: Discontinue concentrator use
immediately if O2 sensor red warning light illuminates;
oxygen concentration is too low for safe use. Contact
your Graham-Field equipment provider immediately.
John Bunn Oꢀ Premier Oxygen Concentrator
7
ꢀ featuRes
summary
The John Bunn O2 Premier oxygen concentrator is intend-
ed for use as an oxygen supplement device in a home or
care facility. Use the concentrator only as prescribed by a
physician.
The concentrator separates oxygen from ambient air,
providing the user a high concentration of oxygen. Oxygen
concentrator usage is therapeutically equivalent to other
types of oxygen delivery systems.
Characteristics
• Reliable, safe, complete plastic outer shell.
• Display screen shows total elapsed working hours.
• Pressure safety valve helps ensure operating pressure.
• Power loss alarm function.
• High and low pressure alarm function.
• Heat protection to ensure the safety of the compressor
and concentrator.
• JB0160-015B, JB0160-015, JB0160-015B-220, and
JB0160-015-220 only: O2 sensor (electro-chemical de-
vice): Yellow fault light illuminates when O2 concen-
tration is greater than 71% and less than 82%; system
works. Red warning light illuminates when O2 concen-
tration is less than 71%; system shuts off.
8
John Bunn Oꢀ Premier Oxygen Concentrator
3 HandlIng
gf Health Products, Inc. freight Policy
for your Protection, Read Carefully
The carrier accepted this merchandise “in good condition”
and is responsible for safe delivery.
Before signing the freight bill, inspect the shipment care-
fully for damage or missing pieces.
Apparent Loss or Damage
Should visual inspection show loss or damage, this MUST
be noted on the freight bill and signed by the carrier’s
agent. Failure to do so may result in the carrier failing to
honor the claim. Please contact the carrier to obtain the
paperwork necessary to file a claim.
Concealed Loss or Damage
If damage is discovered after delivery is made, a concealed
damage claim must be entered with the freight carrier.
When this occurs, make a written request to the carrier
for inspection. This request for inspection must be made
within 15 days of delivery. The carrier will provide all
paperwork necessary to file a concealed damage or loss
claim, since such damage or loss is the carrier’s responsi-
bility.
unpacking
Note: Unless the oxygen concentrator is to be used
immediately, retain containers and packing materials
for storage until concentrator use is required.
1. Check for obvious damage to the carton or its contents.
If damage is evident, please notify the carrier and your
Graham-Field equipment provider.
2. Remove all loose packing from the carton.
3. Carefully remove all the components from the carton.
John Bunn Oꢀ Premier Oxygen Concentrator
9
4 OPeRatIOn and InstallatIOn
Preparing the Concentrator
(refer to above picture)
1. Unscrew the humidifier bottle cover, if so equipped (hu-
midifier bottle is optional).
2. Fill the humidifier bottle with purified water (or dis-
tilled water) between the maximum and minimum water
level lines. If needed, add medication to the water, as
prescribed by physician.
3. Screw the cover back on the humidifier bottle.
4. Screw the humidifier bottle adapter into the humidifier
bottle cover.
5. Insert the humidifier bottle into the elastic belt on the
left side of the unit.
6. Connect the other end of the oxygen hose to the oxygen
outlet.
7. Ensure that the power switch is off; plug the concen-
John Bunn Oꢀ Premier Oxygen Concentrator
11
trator’s AC connector into a properly grounded power
outlet.
turning the Concentrator On
1. Press the power switch to start the concentrator. There
will be a brief delay before the concentrator starts. The
alarm system emits a tone of one second duration, the
word HELLO appears on the hour meter LED panel, and
the green power indicator light illuminates.
ATTENTION: Every time the concentrator starts, the alarm
system performs a self test, and emits a brief tone. If
the alarm does anything other than emit a brief tone,
see Section 6, Troubleshooting Guide, and follow the
appropriate steps.
2. Turn the flowmeter knob to the setting prescribed by
your physician or therapist.
Note: To properly read the flowmeter, locate the prescribed
flowrate line on the flowmeter.
3. Turn the flowmeter knob until the flowmeter ball rises
to the appropriate line.
4. Center the flowmeter ball on the L/min line prescribed.
Damage: If the flowrate on the flowmeter ever falls below
0.5L/min, check tubing or accessories for blocked or
kinked tubing or for a defective humidifier bottle.
s
If using a humidifier bottle, the oxygen comes from the
humidifier bottle outlet.
5. Connect the oxygen tubing barb connector securely to
the humidifier outlet; the other end of the oxygen tub-
ing is used by the patient.
Note: Oxygenation times and the flowrate ranges are
established and prescribed by your physician.
turning the Concentrator Off
Turn off the power switch and unplug the concentrator’s
AC connector from the power outlet.
1ꢀ
John Bunn Oꢀ Premier Oxygen Concentrator
5 MaIntenanCe
Cleaning the Cabinet
Clean the cabinet at least once a month.
1. Turn off the power switch.
2. Clean the cabinet with a mild household cleaner and a
non-abrasive cloth or sponge. Do not spill liquid inside
the cabinet.
Cleaning or Replacing the filters (3 types)
Clean or replace the filters as often as specified in the
following paragraphs in order to protect the compressor
and extend the concentrator’s life. Replacement filters are
available from your Graham-Field equipment provider.
Bottom filter
The bottom filter does not typically require cleaning, but
it may if operated in extremely dirty conditions. Perform a
visual inspection of the bottom filter every 2 weeks; if the
filter is dirty, clean it. The bottom filter is located at the
bottom rear of the cabinet (see Figure 1). To clean:
1. Remove the bottom filter
from the squares carefully
with your fingers.
2. Inspect the filter; if any part
of it is cracked or broken,
replace it instead of clean-
ing it.
3. If cleaning, rinse filter well
with clear water until all dirt is removed.
4. Dry filter by squeezing between two absorbent towels.
Wait for filter to dry. When dry, install filter carefully as
shown in Figure 1.
Damage: Do not operate the concentrator without the
filters installed, or while filters are wet. These actions
could permanently damage the concentrator.
s
John Bunn Oꢀ Premier Oxygen Concentrator
13
Side filters
Note: For earlier models only, you will need a small blade
screwdriver to open the side filter access door. For later
models, the filter grill simply pulls out. If this operation
is too difficult for you to perform, please contact your
equipment provider to perform this for you.
Clean the side filters weekly. There are two side filters, one
located on each side of the concentrator cabinet. Perform
the following steps on both side filters.
1. Turn off the power switch and unplug the concentra-
tor’s AC connector from the power outlet.
2. For earlier models, use a
small blade screwdriver
to open the air intake ac-
cess door; for later mod-
els, open the filter grill
(see Figure 2).
3. Remove the side filter
carefully with your fin-
gers.
4. Inspect the filter; if any
part of it is cracked or broken, replace it instead of
cleaning it.
5. If cleaning, rinse filter well with clear water until all dirt
is removed.
6. To dry filter, squeeze it carefully between two absor-
bent towels . Wait for filter to dry before installing
it in concentrator. When dry, install filter carefully as
shown in Figure 2.
Damage: Do not operate the concentrator without the
filters installed, or while filters are wet. These actions
could permanently damage the concentrator.
s
Damage: Please note that the side filters may require
cleaning more often, especially if the concentrator is
operated where the following conditions exist:
s
14
John Bunn Oꢀ Premier Oxygen Concentrator
• A wood stove is used
• Kerosene or oil is used
• Pets are present
• Tobacco is used
Intake filter
Note: Please have your Graham-Field equipment provider
replace the intake filter. This operation requires
opening the intake filter access door.
Replace, do not clean, the intake filter annually (or more
often, if the intake filter turns black). The frequency of re-
placement depends on usage and condition of the environ-
ment where the concentrator is used.
Cleaning the Optional Humidifier Bottle
Change the water in the humidifier bottle every day. Wash
the humidifier bottle weekly with warm soapy water, rinse
with a solution of 1 part vinegar to 10 parts water, and
rinse thoroughly with hot water before refilling.
Replacing the Battery
Note: Please have your Graham-Field equipment provider
replace the battery. This operation requires opening
the battery access door.
Note This device uses a 9V battery. If the concentrator will
not be used for an extended period, please have your
Graham-Field equipment provider remove the battery.
When the battery becomes weak, the alarm will sound.
Have your Graham-Field equipment provider change the
battery immediately.
ATTENTION: Without the battery, the alarm will not work.
ALWAYS change the battery when necessary.
John Bunn Oꢀ Premier Oxygen Concentrator
15
6 tROuBlesHOOtIng guIde
syMPtOM
CHeCK / aCtIOn
Concentrator power is Check if concentrator is unplugged; plug in.
on and alarm is on, but
concentrator doesn’t
Check if circuit breaker is tripped; fix circuit
work
breaker.
If concentrator still doesn’t work, contact
graham-field equipment provider.
syMPtOM
CHeCK / aCtIOn
Concentrator works,
but little or no oxygen
from outlet
Inspect tubes and cannula to ensure that they are
not kinked or blocked. smooth tubes to unblock.
Check humidifier bottle, if so equipped, for leaks
or jamming. Give humidifier bottle a slight shake
to open safety valve. Clean humidifier bottle,
reinstall and tighten.
If condition persists, contact graham-field
equipment provider.
syMPtOM
CHeCK / aCtIOn
Flowmeter ball located Adjust flowmeter knob. If condition persists,
on “0” position or float contact Graham-Field equipment provider.
is unstable
syMPtOM
CHeCK / aCtIOn
Concentrator works,
but makes abnormal
sound
If yellow light blinks, and alarm sounds at low
intervals, or yellow light illuminates continuously
and alarm sounds, contact graham-field
equipment provider.
syMPtOM
CHeCK / aCtIOn
Concentrator works,
but yellow fault light
lluminates
(JB0160-015B,
JB0160-015,
OK to continue use, but contact graham-field
equipment provider immediately. Concentrator’s
oxygen concentration is safe, but decreasing.
When oxygen concentration is too low for safe
use, concentrator will shut off and optional Oꢀ
sensor red warning light will illuminate.
JB0160-015B-ꢀꢀ0,
JB0160-015-ꢀꢀ0 only)
16
John Bunn Oꢀ Premier Oxygen Concentrator
syMPtOM
CHeCK / aCtIOn
Concentrator doesn’t
work; alarm sounds;
optional Oꢀ sensor red
warning light
discontinue use; contact graham-field equipment
provider immediately. Oxygen concentration is too
low for safe use.
illuminates
(JB0160-015B,
JB0160-015,
JB0160-015B-ꢀꢀ0,
JB0160-015-ꢀꢀ0 only)
Note: If you experience a problem with your concentrator
and are unable to service it yourself, contact the
equipment provider from whom you purchased the
concentrator. If the equipment provider is unable to
help you, contact Graham-Field’s Customer Service
Department at 800-347-5678.
John Bunn Oꢀ Premier Oxygen Concentrator
17
7 BIll Of MateRIals
Your concentrator includes the following components:
• Oxygen concentrator (one each)
• User manual (one each)
• Humidifier bottle hose (one each)
• Humidifier bottle adapter (one each)
The concentrator comes with one bottom filter, two
side filters, and one intake filter already installed; Model
Nos. JB0160-015B, JB0160-015, JB0160-015B-220 and
JB0160-015-220 come with one O2 sensor already installed.
Replacement Parts and Optional accessories
Replacement parts and optional accessories are available
for your concentrator. Please contact your Graham-Field
equipment provider to order replacement parts and/or ac-
cessories.
For a list of available replacement parts and optional ac-
cessories, please visit www.grahamfield.com
18
John Bunn Oꢀ Premier Oxygen Concentrator
8 sPeCIfICatIOns
• Flow Range: 1 to 5L/min
• Oxygen Concentration: 1-4 LPM 94% 2%
5 LPM 92% 2%
• Maximum Outlet Pressure: 6.52 psi .065 psi
(45kPa 4.5kPa)
• Pressure Relief Mechanism Operational at:
36.26 psi 3.63 psi (250kPa 25kPa)
• Altitude: Up to 5,997 feet (1,828 meters) above sea level
without degradation of concentration levels. Efficiency
of 90% from 5,997 to 13,123 feet (1,828 to 4,000 meters)
above sea level.
• Sound Level: ≤ 55dB
• Power Supply: JB0160-010B, JB0160-010, JB0160-015B,
JB0160-015: AC120V 10% (60Hz) (4.6amps).
JB0160-010B-220, JB0160-010-220, JB0160-015B-220,
JB0160-015-220: AC220V 10% (50Hz) (2.2amps)
• Input Power: 400 Watts Average
• Weight: 57lbs (26kg)
• Dimensions: H 27” x W 18” x D 15”
• Minimum Warm-Up Time Before Use: 30 minutes
• Electrical Classification: II Class B Type
• System: Continuous
• JB0160-015B, JB0160-015, JB0160-015B-220,
JB0160-015-220 only: O2 sensor (electro-chemical de-
vice): Yellow fault light illuminates when O2 concen-
tration is greater than 71% and less than 82%; system
works. Red warning light illuminates when O2 concentra-
tion is less than 71%; system shuts off.
Normal Operation Conditions
• Temperature range: 41°F to 104°F (5°C to 40°C)
• Relative humidity: 20% to 60%
• Atmospheric pressure: 12.47 psi to 15.37 psi
(86kPa to 106kPa)
John Bunn Oꢀ Premier Oxygen Concentrator
19
9 lIMIted WaRRanty
This warranty is extended only to the original purchaser of
our products. This warranty gives you specific legal rights
and you may also have other legal rights which may vary
from state to state. GF Health Products, Inc. warrants its
John Bunn O2 Premier Oxygen Concentrator to be free from
defects in materials and workmanship from the date of pur-
chase for the following time period:
Compressor:
six (6) years
Balance of concentrator: five (5) years
Removal of the concentrator cover, unauthorized attempts to
service the unit or unauthorized replacement of parts, other
than routine maintenance, as described in this user manual,
will void all warranties applicable to this concentrator device.
If within such warranty period any such product shall be
proven to GF Health Products, Inc.’s satisfaction to be defec-
tive, such product shall be repaired or replaced, at GF Health
Products, Inc.’s option. This warranty only applies to the
labor for repairs performed by the authorized Equipment Pro-
viders. It does not apply to the labor performed by the pur-
chaser or user. This warranty does not include normal wear
and tear or shipping charges. GF Health Products, Inc.’s sole
obligation and your exclusive remedy under this warranty
shall be limited to such repair or replacement.
Routine maintenance items, such as filters, are excluded from
this warranty. For warranty service, please contact GF Health
Products, Inc.’s Customer Service. Upon receiving notice of
an alleged defect in a product, GF Health Products, Inc. will
issue a serialized return authorization. It shall then be the
responsibility of the purchaser to return the entire unit or
remove, at purchaser’s cost, the defective component part(s)
identified, pack the component part(s) in a manner to avoid
shipping damage and to ship the component part(s) to either
GF Health Products, Inc. or an Authorized Equipment Provid-
er, as specified by GF Health Products, Inc. in advance.
Defective component part(s) must be returned for warranty
inspection, using the serialized return authorization number
ꢀ0
John Bunn Oꢀ Premier Oxygen Concentrator
as identification, within thirty (30) days of the return autho-
rization date. Do not return products to GF Health Products,
Inc. or its Authorized Equipment Providers, without prior
consent. C.O.D. shipments will be refused. All return ship-
ments must prepay shipping charges, unless otherwise au-
thorized by GF Health Products, Inc.
Concentrator warranty for the John Bunn O2 Premier Oxy-
gen Concentrator (part numbers JB0160-010B, JB0160-010,
JB0160-010B-220, JB0160-010-220, JB0160-015B, JB0160-015,
JB0160-015B-220, JB0160-015-220) limitations and exclusions:
The foregoing warranty shall not apply to products subjected
to negligence; accident; improper operation, maintenance
or storage; soot or smoke-filled environments; other than
normal application, use or service; modification without GF
Health Products, Inc.’s express written consent (including,
but not limited to, modification through the use of unauthor-
ized parts or attachments); damage by reason of repairs
made to any component without the specific consent of GF
Health Products, Inc.; or to products damaged by circum-
stances beyond GF Health Products, Inc.’s control.
The foregoing express warranty is exclusive and in lieu of any
other warranties whatsoever, whether express or implied, in-
cluding the implied warranties of merchantability and fitness
for a particular purpose; and the sole remedy for violations of
any warranty whatsoever shall be limited to repair or replace-
ment of the defective product pursuant to the terms con-
tained herein. The application of any implied warranty what-
soever shall not extend beyond the duration of the express
warranty provided herein. GF Health Products, Inc. shall not
be liable for any consequential or incidental damages whatso-
ever. Some states do not allow the exclusion or limitation of
incidental or consequential damage, or limitation of how long
an implied warranty lasts, so the above exclusion and limita-
tion may not apply to you. This warranty shall be extended to
comply with state/provincial laws and requirements.
Note: The above warranty has been written to comply with
Federal Law applicable to products manufactured after
July 4, 1975.
John Bunn Oꢀ Premier Oxygen Concentrator
ꢀ1
10 Index
a
R
Radio Frequency Interference
(RFI) 5
B
Replacement parts and op-
C
s
Safety 3
Specifications 19
Storage 10
d
t
f
Turning the concentrator off
Features 8
Filters, cleaning or replacing
Turning the concentrator on
Fire warning & explosion,
safety 4
Freight policy, Graham-Field’s
u
Unpacking 9
H
W
Handling 9
I
Inspection 10
M
Maintenance 13
n
O
P
ꢀꢀ
John Bunn Oꢀ Premier Oxygen Concentrator
nOtes
John Bunn Oꢀ Premier Oxygen Concentrator
ꢀ3
regIster
®
yOUr
PRODUCT!
The benefits of registering:
• Safeguard your investment.
• Ensure long-term maintenance and servicing of your
purchase.
• Receive updates with product information, mainte-
nance tips, and industry news.
• GF Health Products, Inc. can contact your or your pro-
vider, if servicing is needed on your product.
• It will enable GF Health Products, Inc. to improve prod-
uct designs based on your input and needs.
To register your product:
• Complete the form and questionnaire on the next page.
• Cut out the page on the dotted line.
• Fold the page along the middle with the questionnaire
on the inside, and the address on the outside.
• Fill out your return address.
• Affix first-class postage.
• Mail to Graham-Field Health Products. Thank you!
ꢀ4
John Bunn Oꢀ Premier Oxygen Concentrator
QuestIOnnaIRe
1. Method of purchase: (check all that apply)
�Medicare �Insurance �Medicaid �Other
2. This product was purchased for use by: (check one)
�Self �Parent �Spouse �Other
3. This product was purchased for use at:
�Home �Facility �Other
4. I purchased a Graham-Field product because:
�Price �Features (list features) �Other
5. Who referred you to Graham-Field products? (check all that apply)
�Doctor �Therapist �Friend
�Relative �Dealer/Provider �Other
�Advertisement (circle one): TV, Radio, Magazine, Newspaper
�No Referral
6. What additional features, if any, would you like to see on this
product?
7. Would you like to receive information about Graham-Field products
that may be available for a particular medical condition?
�Yes �No
If yes, please list any condition(s) here and we will send you
information by email and/or regular mail about any available
Graham-Field products that may help treat, care for or manage such
condition(s):
8. Would you like to receive updated information via email or regular
mail about Graham-Field home medical products? �Yes �No
9. What would you like to see on the Graham-Field website?
10.Would you like to be part of future surveys for Graham-Field
products? �Yes �No
11.User’s year of birth:_______________
If at any time you wish not to receive future mailings from us, please
contact us at GF Health Products, Inc., 2935 Northeast Parkway,
Atlanta, GA 30360, 800-347-5678
Affix
first-class
postage
here
GF Health Products, Inc.
2935 Northeast Parkway
Atlanta, GA 30360
USA, Corporate Headquarters:
Graham-Field Health Products
2935 Northeast Parkway
Atlanta, Georgia 30360
telephone: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
GF0600004RevH07
©GF Health Products, Inc.
printed in China
John Bunn, O2 Premier, GF, and Graham-Field