Graham Field Oxygen Equipment JB0160 010 User Manual

Oxygen COnCentratOr  
User ManUal  
Model numbers JB0160-010B, JB0160-010,  
JB0160-010B-220, JB0160-010-220  
and  
JB0160-015B, JB0160-015, JB0160-015B-220,  
JB0160-015-220 with O2 sensor  
Important: Do not operate this concentrator without  
first reading and understanding this manual!  
save this manual for future use.  
 
Federal Law (USA) restricts this device to sale by or  
on the order of a physician. This product should not  
be used unless the operator has been instructed by a  
qualified health care professional.  
WARNING: Users who require continuous oxygenation  
must plan for alternate reserve sources of power and  
oxygen in the event of a failure or loss of power and  
oxygen. This device is to be used ONLY as an oxygen  
supplement device and is NOT intended to be a life-  
supporting or life-sustaining device.  
1 safety  
The John Bunn O2 Premier oxygen concentrator is intend-  
ed for use as an oxygen supplement device in a home or  
care facility. Use the concentrator only as prescribed by a  
physician. This user manual serves as a reference for your  
oxygen concentrator.  
Important Information  
Please note the following special statements, used  
throughout this manual, and their significance:  
Note: Explanatory information.  
Damage: Action could result in damage to equipment.  
ATTENTION: Action could result in personal injury.  
CAUTION: Action could result in electric shock.  
WARNING: Action could result in fire and explosion.  
s
Before Installation  
Damage: During transport, always keep the concentrator  
upright to prevent damage.  
s
Damage: Only use stable and safe electrical power  
sources.  
s
John Bunn Oꢀ Premier Oxygen Concentrator  
3
 
 
Damage: If the electrical power source becomes  
unstable, discontinue use and find an alternate source.  
s
s
Damage: The oxygen concentrator cabinet contains no  
serviceable parts! The oxygen concentrator cabinet  
should ONLY be opened by an authorized equipment  
provider.  
Placement  
ATTENTION: The oxygen concentrator is intended to  
be rolled from room to room. Do not place the oxygen  
concentrator in surroundings where its airflow is  
obstructed.  
ATTENTION: Be certain to place the unit so that all sides  
are at least 12 inches (30 cm) away from walls, draperies,  
furniture, or other obstructions. Do not place the unit in a  
confined area.  
ATTENTION: The oxygen concentrator MUST be kept  
away from heat, fire and excessive water sources and  
conditions.  
ATTENTION: Do not place items on top of the  
concentrator.  
ATTENTION: NEVER block the concentrators air openings.  
ATTENTION: Always place the concentrator on a hard  
surface. Never place the concentrator on a surface such  
as bed or couch, where the concentrator may tip or fall.  
ATTENTION: Keep the concentrator openings free from  
lint, hair, etc.  
fire Warning & explosion  
WARNING: Keep the concentrator away from flammable  
and explosive areas.  
4
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
WARNING: To reduce the risk of fire, special care must  
be taken when using oxygen concentrators. DO NOT  
SMOKE while using this device. Keep all matches, lighted  
cigarettes or other sources of ignition out of the room in  
which this concentrator is located. In public settings or  
when used in hospital or long-term care environments,  
prominently display NO SMOKING signs.  
WARNING: Textiles and other materials that normally  
would not easily burn, can ignite and burn with great  
intensity in oxygen enriched air.  
WARNING: A spontaneous and violent ignition may occur  
if oil, grease or greasy substances come in contact with  
oxygen under pressure. ALWAYS keep these substances  
away from the oxygen concentrator and all other  
oxygen equipment. DO NOT use any lubricants unless  
recommended by manufacturer.  
WARNING: Failure to observe these warnings can result in  
severe fire, property damage and cause physical injury or  
DEATH.  
Maintenance  
CAUTION: The oxygen concentrator was specifically  
designed to minimize routine preventive maintenance.  
Only an authorized equipment provider or factory-trained  
personnel should perform preventive maintenance or  
adjustments to the oxygen concentrator.  
Radio frequency Interference  
Most electronic equipment is influenced by Radio Fre-  
quency Interference (RFI). ALWAYS exercise CAUTION with  
regard to the use of portable communications equipment  
in the area around such equipment.  
John Bunn Oꢀ Premier Oxygen Concentrator  
5
 
 
additional safety Warnings  
WARNING: TO REDUCE THE RISK OF BURNS,  
ELECTROCUTION, FIRE OR INJURY TO PERSONS, avoid  
using while bathing. If continuous usage is required by  
the direction of a physician, the concentrator must be  
located in another room at least 9 feet (2.8m) from the  
bath.  
WARNING: DO NOT reach for a concentrator that has  
fallen into water. UNPLUG IT IMMEDIATELY.  
WARNING: In certain circumstances, oxygen therapy can  
be hazardous. Graham-Field recommends that you seek  
medical advice before using this product.  
WARNING: Avoid creation of any spark near medical  
oxygen equipment. This includes sparks from static  
electricity created by any type of friction.  
ATTENTION: DO NOT come in contact with the concentrator  
when you are wet.  
ATTENTION: DO NOT place or store the concentrator where  
it can drop into water or other liquid.  
ATTENTION: NEVER leave the concentrator unattended  
when plugged in.  
ATTENTION: This device is to be used only in accordance  
with the prescription of a physician and this user manual.  
If at any time the patient or attendant concludes that  
the patient is receiving an insufficient amount of oxygen,  
contact the provider and/or physician immediately.  
NEVER make adjustments to the flow rate unless  
prescribed by a physician.  
6
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
ATTENTION: ALWAYS supervise closely when this  
product is used near children or those who require close  
supervision.  
ATTENTION: Only use this device as intended and  
described in this manual.  
ATTENTION: DO NOT use parts, accessories or adapters  
other than those authorized by manufacturer.  
ATTENTION: DO NOT connect the concentrator in parallel  
or series with other oxygen concentrators or oxygen  
therapy devices.  
ATTENTION: JB0160-015B, JB0160-015, JB0160-015B-220  
and JB0160-015-220 only: Discontinue concentrator use  
immediately if O2 sensor red warning light illuminates;  
oxygen concentration is too low for safe use. Contact  
your Graham-Field equipment provider immediately.  
John Bunn Oꢀ Premier Oxygen Concentrator  
7
 
ꢀ featuRes  
summary  
The John Bunn O2 Premier oxygen concentrator is intend-  
ed for use as an oxygen supplement device in a home or  
care facility. Use the concentrator only as prescribed by a  
physician.  
The concentrator separates oxygen from ambient air,  
providing the user a high concentration of oxygen. Oxygen  
concentrator usage is therapeutically equivalent to other  
types of oxygen delivery systems.  
Characteristics  
• Reliable, safe, complete plastic outer shell.  
• Display screen shows total elapsed working hours.  
• Pressure safety valve helps ensure operating pressure.  
• Power loss alarm function.  
• High and low pressure alarm function.  
• Heat protection to ensure the safety of the compressor  
and concentrator.  
• JB0160-015B, JB0160-015, JB0160-015B-220, and  
JB0160-015-220 only: O2 sensor (electro-chemical de-  
vice): Yellow fault light illuminates when O2 concen-  
tration is greater than 71% and less than 82%; system  
works. Red warning light illuminates when O2 concen-  
tration is less than 71%; system shuts off.  
8
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
3 HandlIng  
gf Health Products, Inc. freight Policy  
for your Protection, Read Carefully  
The carrier accepted this merchandise “in good condition”  
and is responsible for safe delivery.  
Before signing the freight bill, inspect the shipment care-  
fully for damage or missing pieces.  
Apparent Loss or Damage  
Should visual inspection show loss or damage, this MUST  
be noted on the freight bill and signed by the carrier’s  
agent. Failure to do so may result in the carrier failing to  
honor the claim. Please contact the carrier to obtain the  
paperwork necessary to file a claim.  
Concealed Loss or Damage  
If damage is discovered after delivery is made, a concealed  
damage claim must be entered with the freight carrier.  
When this occurs, make a written request to the carrier  
for inspection. This request for inspection must be made  
within 15 days of delivery. The carrier will provide all  
paperwork necessary to file a concealed damage or loss  
claim, since such damage or loss is the carrier’s responsi-  
bility.  
unpacking  
Note: Unless the oxygen concentrator is to be used  
immediately, retain containers and packing materials  
for storage until concentrator use is required.  
1. Check for obvious damage to the carton or its contents.  
If damage is evident, please notify the carrier and your  
Graham-Field equipment provider.  
2. Remove all loose packing from the carton.  
3. Carefully remove all the components from the carton.  
John Bunn Oꢀ Premier Oxygen Concentrator  
9
 
 
Inspection  
Examine exterior of the oxygen concentrator for nicks,  
dents, scratches or other damages. Inspect all compo-  
nents.  
storage  
Store the repackaged oxygen concentrator in a dry area.  
DO NOT place anything on top of the repackaged concen-  
trator.  
10  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
4 OPeRatIOn and InstallatIOn  
Preparing the Concentrator  
(refer to above picture)  
1. Unscrew the humidifier bottle cover, if so equipped (hu-  
midifier bottle is optional).  
2. Fill the humidifier bottle with purified water (or dis-  
tilled water) between the maximum and minimum water  
level lines. If needed, add medication to the water, as  
prescribed by physician.  
3. Screw the cover back on the humidifier bottle.  
4. Screw the humidifier bottle adapter into the humidifier  
bottle cover.  
5. Insert the humidifier bottle into the elastic belt on the  
left side of the unit.  
6. Connect the other end of the oxygen hose to the oxygen  
outlet.  
7. Ensure that the power switch is off; plug the concen-  
John Bunn Oꢀ Premier Oxygen Concentrator  
11  
 
 
trator’s AC connector into a properly grounded power  
outlet.  
turning the Concentrator On  
1. Press the power switch to start the concentrator. There  
will be a brief delay before the concentrator starts. The  
alarm system emits a tone of one second duration, the  
word HELLO appears on the hour meter LED panel, and  
the green power indicator light illuminates.  
ATTENTION: Every time the concentrator starts, the alarm  
system performs a self test, and emits a brief tone. If  
the alarm does anything other than emit a brief tone,  
see Section 6, Troubleshooting Guide, and follow the  
appropriate steps.  
2. Turn the flowmeter knob to the setting prescribed by  
your physician or therapist.  
Note: To properly read the flowmeter, locate the prescribed  
flowrate line on the flowmeter.  
3. Turn the flowmeter knob until the flowmeter ball rises  
to the appropriate line.  
4. Center the flowmeter ball on the L/min line prescribed.  
Damage: If the flowrate on the flowmeter ever falls below  
0.5L/min, check tubing or accessories for blocked or  
kinked tubing or for a defective humidifier bottle.  
s
If using a humidifier bottle, the oxygen comes from the  
humidifier bottle outlet.  
5. Connect the oxygen tubing barb connector securely to  
the humidifier outlet; the other end of the oxygen tub-  
ing is used by the patient.  
Note: Oxygenation times and the flowrate ranges are  
established and prescribed by your physician.  
turning the Concentrator Off  
Turn off the power switch and unplug the concentrator’s  
AC connector from the power outlet.  
1ꢀ  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
5 MaIntenanCe  
Cleaning the Cabinet  
Clean the cabinet at least once a month.  
1. Turn off the power switch.  
2. Clean the cabinet with a mild household cleaner and a  
non-abrasive cloth or sponge. Do not spill liquid inside  
the cabinet.  
Cleaning or Replacing the filters (3 types)  
Clean or replace the filters as often as specified in the  
following paragraphs in order to protect the compressor  
and extend the concentrator’s life. Replacement filters are  
available from your Graham-Field equipment provider.  
Bottom filter  
The bottom filter does not typically require cleaning, but  
it may if operated in extremely dirty conditions. Perform a  
visual inspection of the bottom filter every 2 weeks; if the  
filter is dirty, clean it. The bottom filter is located at the  
bottom rear of the cabinet (see Figure 1). To clean:  
1. Remove the bottom filter  
from the squares carefully  
with your fingers.  
2. Inspect the filter; if any part  
of it is cracked or broken,  
replace it instead of clean-  
ing it.  
3. If cleaning, rinse filter well  
with clear water until all dirt is removed.  
4. Dry filter by squeezing between two absorbent towels.  
Wait for filter to dry. When dry, install filter carefully as  
shown in Figure 1.  
Damage: Do not operate the concentrator without the  
filters installed, or while filters are wet. These actions  
could permanently damage the concentrator.  
s
John Bunn Oꢀ Premier Oxygen Concentrator  
13  
 
 
Side filters  
Note: For earlier models only, you will need a small blade  
screwdriver to open the side filter access door. For later  
models, the filter grill simply pulls out. If this operation  
is too difficult for you to perform, please contact your  
equipment provider to perform this for you.  
Clean the side filters weekly. There are two side filters, one  
located on each side of the concentrator cabinet. Perform  
the following steps on both side filters.  
1. Turn off the power switch and unplug the concentra-  
tor’s AC connector from the power outlet.  
2. For earlier models, use a  
small blade screwdriver  
to open the air intake ac-  
cess door; for later mod-  
els, open the filter grill  
(see Figure 2).  
3. Remove the side filter  
carefully with your fin-  
gers.  
4. Inspect the filter; if any  
part of it is cracked or broken, replace it instead of  
cleaning it.  
5. If cleaning, rinse filter well with clear water until all dirt  
is removed.  
6. To dry filter, squeeze it carefully between two absor-  
bent towels . Wait for filter to dry before installing  
it in concentrator. When dry, install filter carefully as  
shown in Figure 2.  
Damage: Do not operate the concentrator without the  
filters installed, or while filters are wet. These actions  
could permanently damage the concentrator.  
s
Damage: Please note that the side filters may require  
cleaning more often, especially if the concentrator is  
operated where the following conditions exist:  
s
14  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
• A wood stove is used  
• Kerosene or oil is used  
• Pets are present  
• Tobacco is used  
Intake filter  
Note: Please have your Graham-Field equipment provider  
replace the intake filter. This operation requires  
opening the intake filter access door.  
Replace, do not clean, the intake filter annually (or more  
often, if the intake filter turns black). The frequency of re-  
placement depends on usage and condition of the environ-  
ment where the concentrator is used.  
Cleaning the Optional Humidifier Bottle  
Change the water in the humidifier bottle every day. Wash  
the humidifier bottle weekly with warm soapy water, rinse  
with a solution of 1 part vinegar to 10 parts water, and  
rinse thoroughly with hot water before refilling.  
Replacing the Battery  
Note: Please have your Graham-Field equipment provider  
replace the battery. This operation requires opening  
the battery access door.  
Note This device uses a 9V battery. If the concentrator will  
not be used for an extended period, please have your  
Graham-Field equipment provider remove the battery.  
When the battery becomes weak, the alarm will sound.  
Have your Graham-Field equipment provider change the  
battery immediately.  
ATTENTION: Without the battery, the alarm will not work.  
ALWAYS change the battery when necessary.  
John Bunn Oꢀ Premier Oxygen Concentrator  
15  
 
 
6 tROuBlesHOOtIng guIde  
syMPtOM  
CHeCK / aCtIOn  
Concentrator power is Check if concentrator is unplugged; plug in.  
on and alarm is on, but  
concentrator doesn’t  
Check if circuit breaker is tripped; fix circuit  
work  
breaker.  
If concentrator still doesn’t work, contact  
graham-field equipment provider.  
syMPtOM  
CHeCK / aCtIOn  
Concentrator works,  
but little or no oxygen  
from outlet  
Inspect tubes and cannula to ensure that they are  
not kinked or blocked. smooth tubes to unblock.  
Check humidifier bottle, if so equipped, for leaks  
or jamming. Give humidifier bottle a slight shake  
to open safety valve. Clean humidifier bottle,  
reinstall and tighten.  
If condition persists, contact graham-field  
equipment provider.  
syMPtOM  
CHeCK / aCtIOn  
Flowmeter ball located Adjust flowmeter knob. If condition persists,  
on “0” position or float contact Graham-Field equipment provider.  
is unstable  
syMPtOM  
CHeCK / aCtIOn  
Concentrator works,  
but makes abnormal  
sound  
If yellow light blinks, and alarm sounds at low  
intervals, or yellow light illuminates continuously  
and alarm sounds, contact graham-field  
equipment provider.  
syMPtOM  
CHeCK / aCtIOn  
Concentrator works,  
but yellow fault light  
lluminates  
(JB0160-015B,  
JB0160-015,  
OK to continue use, but contact graham-field  
equipment provider immediately. Concentrator’s  
oxygen concentration is safe, but decreasing.  
When oxygen concentration is too low for safe  
use, concentrator will shut off and optional Oꢀ  
sensor red warning light will illuminate.  
JB0160-015B-ꢀꢀ0,  
JB0160-015-ꢀꢀ0 only)  
16  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
syMPtOM  
CHeCK / aCtIOn  
Concentrator doesn’t  
work; alarm sounds;  
optional Osensor red  
warning light  
discontinue use; contact graham-field equipment  
provider immediately. Oxygen concentration is too  
low for safe use.  
illuminates  
(JB0160-015B,  
JB0160-015,  
JB0160-015B-ꢀꢀ0,  
JB0160-015-ꢀꢀ0 only)  
Note: If you experience a problem with your concentrator  
and are unable to service it yourself, contact the  
equipment provider from whom you purchased the  
concentrator. If the equipment provider is unable to  
help you, contact Graham-Field’s Customer Service  
Department at 800-347-5678.  
John Bunn Oꢀ Premier Oxygen Concentrator  
17  
 
7 BIll Of MateRIals  
Your concentrator includes the following components:  
• Oxygen concentrator (one each)  
• User manual (one each)  
• Humidifier bottle hose (one each)  
• Humidifier bottle adapter (one each)  
The concentrator comes with one bottom filter, two  
side filters, and one intake filter already installed; Model  
Nos. JB0160-015B, JB0160-015, JB0160-015B-220 and  
JB0160-015-220 come with one O2 sensor already installed.  
Replacement Parts and Optional accessories  
Replacement parts and optional accessories are available  
for your concentrator. Please contact your Graham-Field  
equipment provider to order replacement parts and/or ac-  
cessories.  
For a list of available replacement parts and optional ac-  
cessories, please visit www.grahamfield.com  
18  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
8 sPeCIfICatIOns  
• Flow Range: 1 to 5L/min  
• Oxygen Concentration: 1-4 LPM 94% 2%  
5 LPM 92% 2%  
• Maximum Outlet Pressure: 6.52 psi .065 psi  
(45kPa 4.5kPa)  
• Pressure Relief Mechanism Operational at:  
36.26 psi 3.63 psi (250kPa 25kPa)  
• Altitude: Up to 5,997 feet (1,828 meters) above sea level  
without degradation of concentration levels. Efficiency  
of 90% from 5,997 to 13,123 feet (1,828 to 4,000 meters)  
above sea level.  
• Sound Level: ≤ 55dB  
• Power Supply: JB0160-010B, JB0160-010, JB0160-015B,  
JB0160-015: AC120V 10% (60Hz) (4.6amps).  
JB0160-010B-220, JB0160-010-220, JB0160-015B-220,  
JB0160-015-220: AC220V 10% (50Hz) (2.2amps)  
• Input Power: 400 Watts Average  
• Weight: 57lbs (26kg)  
• Dimensions: H 27” x W 18” x D 15”  
• Minimum Warm-Up Time Before Use: 30 minutes  
• Electrical Classification: II Class B Type  
• System: Continuous  
• JB0160-015B, JB0160-015, JB0160-015B-220,  
JB0160-015-220 only: O2 sensor (electro-chemical de-  
vice): Yellow fault light illuminates when O2 concen-  
tration is greater than 71% and less than 82%; system  
works. Red warning light illuminates when O2 concentra-  
tion is less than 71%; system shuts off.  
Normal Operation Conditions  
• Temperature range: 41°F to 104°F (5°C to 40°C)  
• Relative humidity: 20% to 60%  
• Atmospheric pressure: 12.47 psi to 15.37 psi  
(86kPa to 106kPa)  
John Bunn Oꢀ Premier Oxygen Concentrator  
19  
 
 
9 lIMIted WaRRanty  
This warranty is extended only to the original purchaser of  
our products. This warranty gives you specific legal rights  
and you may also have other legal rights which may vary  
from state to state. GF Health Products, Inc. warrants its  
John Bunn O2 Premier Oxygen Concentrator to be free from  
defects in materials and workmanship from the date of pur-  
chase for the following time period:  
Compressor:  
six (6) years  
Balance of concentrator: five (5) years  
Removal of the concentrator cover, unauthorized attempts to  
service the unit or unauthorized replacement of parts, other  
than routine maintenance, as described in this user manual,  
will void all warranties applicable to this concentrator device.  
If within such warranty period any such product shall be  
proven to GF Health Products, Inc.’s satisfaction to be defec-  
tive, such product shall be repaired or replaced, at GF Health  
Products, Inc.’s option. This warranty only applies to the  
labor for repairs performed by the authorized Equipment Pro-  
viders. It does not apply to the labor performed by the pur-  
chaser or user. This warranty does not include normal wear  
and tear or shipping charges. GF Health Products, Inc.’s sole  
obligation and your exclusive remedy under this warranty  
shall be limited to such repair or replacement.  
Routine maintenance items, such as filters, are excluded from  
this warranty. For warranty service, please contact GF Health  
Products, Inc.’s Customer Service. Upon receiving notice of  
an alleged defect in a product, GF Health Products, Inc. will  
issue a serialized return authorization. It shall then be the  
responsibility of the purchaser to return the entire unit or  
remove, at purchaser’s cost, the defective component part(s)  
identified, pack the component part(s) in a manner to avoid  
shipping damage and to ship the component part(s) to either  
GF Health Products, Inc. or an Authorized Equipment Provid-  
er, as specified by GF Health Products, Inc. in advance.  
Defective component part(s) must be returned for warranty  
inspection, using the serialized return authorization number  
ꢀ0  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
as identification, within thirty (30) days of the return autho-  
rization date. Do not return products to GF Health Products,  
Inc. or its Authorized Equipment Providers, without prior  
consent. C.O.D. shipments will be refused. All return ship-  
ments must prepay shipping charges, unless otherwise au-  
thorized by GF Health Products, Inc.  
Concentrator warranty for the John Bunn O2 Premier Oxy-  
gen Concentrator (part numbers JB0160-010B, JB0160-010,  
JB0160-010B-220, JB0160-010-220, JB0160-015B, JB0160-015,  
JB0160-015B-220, JB0160-015-220) limitations and exclusions:  
The foregoing warranty shall not apply to products subjected  
to negligence; accident; improper operation, maintenance  
or storage; soot or smoke-filled environments; other than  
normal application, use or service; modification without GF  
Health Products, Inc.’s express written consent (including,  
but not limited to, modification through the use of unauthor-  
ized parts or attachments); damage by reason of repairs  
made to any component without the specific consent of GF  
Health Products, Inc.; or to products damaged by circum-  
stances beyond GF Health Products, Inc.’s control.  
The foregoing express warranty is exclusive and in lieu of any  
other warranties whatsoever, whether express or implied, in-  
cluding the implied warranties of merchantability and fitness  
for a particular purpose; and the sole remedy for violations of  
any warranty whatsoever shall be limited to repair or replace-  
ment of the defective product pursuant to the terms con-  
tained herein. The application of any implied warranty what-  
soever shall not extend beyond the duration of the express  
warranty provided herein. GF Health Products, Inc. shall not  
be liable for any consequential or incidental damages whatso-  
ever. Some states do not allow the exclusion or limitation of  
incidental or consequential damage, or limitation of how long  
an implied warranty lasts, so the above exclusion and limita-  
tion may not apply to you. This warranty shall be extended to  
comply with state/provincial laws and requirements.  
Note: The above warranty has been written to comply with  
Federal Law applicable to products manufactured after  
July 4, 1975.  
John Bunn Oꢀ Premier Oxygen Concentrator  
ꢀ1  
 
10 Index  
a
R
ATTENTION, significance 3  
Radio Frequency Interference  
(RFI) 5  
B
Replacement parts and op-  
tional accessories 18  
Replacing the battery 15  
Before installation, safety 3  
Bill of materials 18  
C
s
CAUTION, significance 3  
Cleaning the cabinet 13  
Safety 3  
Safety warnings, additional 6  
Specifications 19  
Storage 10  
d
Damage, significance 3, 14  
t
f
Troubleshooting guide 16  
Turning the concentrator off  
Features 8  
Filters, cleaning or replacing  
Turning the concentrator on  
Fire warning & explosion,  
safety 4  
Freight policy, Graham-Field’s  
u
Unpacking 9  
H
W
Handling 9  
WARNING, significance 3  
Warranty, limited 20  
I
Inspection 10  
M
Maintenance 13  
Maintenance, safety 5  
n
Note, significance 3  
O
Operation and installation 11  
P
Placement, safety 4  
Preparing the concentrator 11  
ꢀꢀ  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
nOtes  
John Bunn Oꢀ Premier Oxygen Concentrator  
ꢀ3  
 
regIster  
®
yOUr  
PRODUCT!  
The benefits of registering:  
• Safeguard your investment.  
• Ensure long-term maintenance and servicing of your  
purchase.  
• Receive updates with product information, mainte-  
nance tips, and industry news.  
• GF Health Products, Inc. can contact your or your pro-  
vider, if servicing is needed on your product.  
• It will enable GF Health Products, Inc. to improve prod-  
uct designs based on your input and needs.  
To register your product:  
• Complete the form and questionnaire on the next page.  
• Cut out the page on the dotted line.  
• Fold the page along the middle with the questionnaire  
on the inside, and the address on the outside.  
• Fill out your return address.  
• Affix first-class postage.  
• Mail to Graham-Field Health Products. Thank you!  
ꢀ4  
John Bunn Oꢀ Premier Oxygen Concentrator  
 
 
QuestIOnnaIRe  
1. Method of purchase: (check all that apply)  
Medicare Insurance Medicaid Other  
2. This product was purchased for use by: (check one)  
Self Parent Spouse Other  
3. This product was purchased for use at:  
Home Facility Other  
4. I purchased a Graham-Field product because:  
Price Features (list features) Other  
5. Who referred you to Graham-Field products? (check all that apply)  
Doctor Therapist Friend  
Relative Dealer/Provider Other  
Advertisement (circle one): TV, Radio, Magazine, Newspaper  
No Referral  
6. What additional features, if any, would you like to see on this  
product?  
7. Would you like to receive information about Graham-Field products  
that may be available for a particular medical condition?  
Yes No  
If yes, please list any condition(s) here and we will send you  
information by email and/or regular mail about any available  
Graham-Field products that may help treat, care for or manage such  
condition(s):  
8. Would you like to receive updated information via email or regular  
mail about Graham-Field home medical products? Yes No  
9. What would you like to see on the Graham-Field website?  
10.Would you like to be part of future surveys for Graham-Field  
products? Yes No  
11.User’s year of birth:_______________  
If at any time you wish not to receive future mailings from us, please  
contact us at GF Health Products, Inc., 2935 Northeast Parkway,  
Atlanta, GA 30360, 800-347-5678  
 
Affix  
first-class  
postage  
here  
GF Health Products, Inc.  
2935 Northeast Parkway  
Atlanta, GA 30360  
 
 
USA, Corporate Headquarters:  
Graham-Field Health Products  
2935 Northeast Parkway  
Atlanta, Georgia 30360  
telephone: 800-347-5678, 770-447-1609  
fax: 800-726-0601, 678-291-3232  
GF0600004RevH07  
©GF Health Products, Inc.  
printed in China  
John Bunn, O2 Premier, GF, and Graham-Field  
are registered trademarks of GF Health Products, Inc.  
 

Gravely Snow Blower 210E+05 User Manual
Guardian Technologies Portable Generator 004270 3 User Manual
Haier Washer HWD D1000TXVE User Manual
Healthrider Treadmill HRTL06900 User Manual
Honeywell Portable Radio TE821WD User Manual
HP Hewlett Packard Printer 1175C User Manual
Hunter Fan Outdoor Ceiling Fan 42027 01 User Manual
Husqvarna Automobile 4210 E User Manual
Husqvarna Cordless Saw WS 462 User Manual
Husqvarna Trimmer 142RB User Manual